Council archive · source document
Decision Notice - 010.2009.00001382.001 [As Published] · 142009.1382
2009/1382
Sunshine Coast Regional Council’s CEO may request further controls to be installed should
approved measures be inefficient.
21. The owners of the subject property shall maintain the grease/oil arrestor pits/gross pollutant
traps in accordance with the manufacturers specifications.
22. The owners of the subject property shall inspect the gross pollutant traps on a weekly basis
and after each storm event.
The owners of the subject property shall enter into an ongoing maintenance contract with a
Registered Contractor to clean and maintain the gross pollutant traps on regular three monthly
cycles and on an “On Call” basis in the case of an emergency.
The management and maintenance of the gross pollutant traps shall be included in the
Community Management Scheme for the completed development.
23. Prior to acceptance of civil works to become Council assets "On Maintenance", the lodgement
of satisfactory “As Constructed” records shall be submitted to Council.
As Constructed drawings and data shall be certified by a qualified experienced Civil Engineer
(RPEQ) for design intent, and a Licensed Surveyor shall certify the cadastre and the location,
level and type of all services and structures. This information shall be submitted to Council for
checking and for Council’s records.
The data must fully detail levels for all engineering works including, but not limited to, drainage
structures, finished ground levels and pavement surface levels. The data shall be submitted in
the Asset Design and As Constructed (ADAC) digital format. Guidelines on the use of ADAC
are available at www.adac.com.au and Council’s “Noosa Planning Scheme Policy 5 –
Engineering Design Standards – Roads, Drainage and Earthworks”.
Approval of works shall not be granted until all As Constructed information has been supplied
and accepted by Council.
24. A 5% cost of works to become Council assets or $1,500 bond (whichever is the greater) will
be imposed on construction works during the maintenance period, which is a minimum period
of 12 months duration. Such bond must be lodged by, and shall only be accepted from the
Developer for the works.
25. The works to become Council assets will not be accepted "On Maintenance" until the
landscaping is completed.
26. These works are also to be in compliance with the relevant conditions of Development Permit
No. 2007/2174.
27. Notwithstanding that Council has checked the plans with due care, where it is found during
construction that variations from Council's standards exist, then Council standards shall apply.
WATER SUPPLY AND SEWERAGE CONDITIONS
28. The existing sewer main within the development site must be capped 1.5 metres from the
existing sewer manhole. This work must be undertaken by Sunshine Coast Water at the
applicants cost.
29. Proposed tree plantings must maintain a minimum horizontal clearance of 1.5 metres from
Council sewerage infrastructure. Landscaping plants within these clearances must be low
growing when mature and suitable Council approved varieties.
30. Stormwater retention systems and gross pollutant traps must maintain a minimum of 1.5
metres horizontal clearance from Council sewerage infrastructure and 1.0 metre from the
sewer house connection.
31. A water service, in accordance with the hydraulic engineers requirements, must be installed
from the existing water main in Elanda street to the property boundary.
32. A water supply enveloper pipe shall be provided under Elanda Street, if required, in
accordance with Sunshine Coast Water requirements.
Page 4 of 9
This page was created using easyPDF SDK trial software.
To purchase, go to http://www.bcltechnologies.com/easypdf/
See the original