Original source · versioned page text
Attachment 1D - UNITS 6-7 TYPE 2 DAVID LOW WAY
Attached to the e-mail RESPONSE to Information Request.
PEREGIAN BEACH VILLAS
UNITS 6-7, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
Sheet Index
Layout ID Layout Name Published
Sheet Index
A.01.1 COVER PAGE
A.01.2 GROUND FLOOR
A.01.3 FIRST FLOOR
A.01.4 ELEVATIONS
A.01.5 ELEVATIONS
NOTES
INSERT SKETCH RENDER
FOR CONSTRUCTION OF CONCRETE SLAB, FLOOR SYSTEMS, FRAMES & TRUSS'S PLEASE REFER TO HINTON STEEL FRAMES DRAWINGS
AREAS
GENERAL NOTES GROSS FLOOR AREA
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL UNIT 8: 55m2
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA. AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS. STANDARDS. UNIT 9: 55 m2
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND WITH THE B.C.A. REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SCHEDULES OF FINISHES.
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
DIMENSIONS TAKE PRECEDENCE OVER SCALE. AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND AS3788 & PART 3.72 OF THE BCA
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
Collins Developments
DIRECTLY TO THE SUPERINTENDENT. BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING HINTON STEEL FRAMES
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm 16 Computer Road Yatala
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, THE ENTRY OF MOISTURE INTO THE BUILDING. AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL Gold Coast
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REQUIREMENTS qld australia 4207
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION telephone
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. 3.8.1 OF THE B.C.A AND AS 3740 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET (617) 3287 3398
facsimilie
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER (617) 3382 7656
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS email: [email protected]
FOR MEMBER SIZES w w w .h i n t o n s t e e l f r a m e s .c o m .a u
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 4 pages
Page 2
GENERAL NOTES
PEREGIAN BEACH VILLAS UNITS 6-7, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
5,030 5,030 STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
90 1,725 90 3,000 250 3,000 90 1,725 90 ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
90 1,725 1,090 90 1,910 250 1,910 90 1,090 1,725 90
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
440
440
THE ENTRY OF MOISTURE INTO THE BUILDING.
CL
CL
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
Patio 3.8.1 OF THE B.C.A AND AS 3740
Patio
1,000
1,000
1.0 x 4.9
930
930
1.0 x 4.9 ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
STANDARDS.
90
90
90
90
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
2,480
2,480
Ens Bed Bed Ens AS3788 & PART 3.72 OF THE BCA
3,300
3,300
2.5 x 1.7 3.3 x 3.0 3.3 x 3.0 2.5 x 1.7
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
WC WC
MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
90
90
Bi-fold doors by AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
REQUIREMENTS
cabinet maker
820
820
16 16
W W
90
90
15 Laundry Laundry 15 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
14 under under AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
T ROBE ROBE T 14
550
550
13 stair stair 13 FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
12 12 FOR MEMBER SIZES
90
90
LEGEND
11 11
11,340
11,340
10 UNIT 6 UNIT 7 10
9 9 A/C AIR CONDITIONING AS SPEC. - INSTALLED
3,580
3,580
8 8 BY CONTRACTOR
7 7 AP 450 X450 REMOVABLE ACCESS
6 6 PANEL - LOCATION TO BE CONFIRMED ON SITE
5 5 BL CONC. BLOCK WALL TO STRUCTURAL ENG.
4 4 DETAIL - RENDER AND PAINT AS SPEC.
3 3
CF COLORBOND FLASHING TO DETAIL
2 2
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
Single Garage Single Garage CONC CONCRETE SLAB TO ENG. DETAIL
6,000
6,000
1 1
6.0 x 3.3 6.0 x 3.3 CPD CUPBOARD
DP 90mm DIA DOWNPIPE AS SPEC.
1,210
1,210
REFER TO DETAILS FOR TYPICAL FIXING
DRY CLOTHES DRYER
DW DISHWASHER
EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
90
90
GUTTER BRACKETS @ MAX 900 CRS
EGL EXISTING GROUNDLINE
F REFRIGERATOR
1,980
1,980
FW FLOOR WASTE
GD S.S GRATED DRAIN AS SPEC.
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
90
90
HP HOT PLATES AS SPEC.
HWU HOT WATER
130
130
MR MECHANICAL RISER
MW MICROWAVE
NGL NATURAL GROUND LINE
1800H timber fence 90
900 3,915 250 3,915 900 90 OV OVEN
P PANTRY
PGL PROPOSED GROUNDLINE
1,515 90 3,300 250 3,300 90 1,515 PTF POLISHED TIMBER FLOOR AS SPEC.
RHS RHS TO STRUCTURAL. ENG. DETAIL
RV "WIRILY BIRD" OR SIM. APPROVED
5,030 5,030 S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 20.03.14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Revised site plan + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16-01-14 Amend GFA CT Date:
UNITS 6-7, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT
PH: 0410 650 745
GROUND FLOOR
BSB No.: 1043429
F 24-01-14 Client request amendments CT NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
G 04.03.14 Amend design & balcony
H 20.03.14 Amend design & Areas
CT
CT
ECO REMOTE A.01.2 H
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 3
GENERAL NOTES
PEREGIAN BEACH VILLAS UNITS 6-7, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
410 5,030 5,030 410 ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
90 1,320 90 3,815 250 3,815 90 1,320 90
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
THE ENTRY OF MOISTURE INTO THE BUILDING.
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
3.8.1 OF THE B.C.A AND AS 3740
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
Outdoor living Outdoor living
2,080
2,080
2,080
2,080
AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
4.9 x 2.1 4.9 x 2.1 STANDARDS.
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
90
90
90
90
AS3788 & PART 3.72 OF THE BCA
Bay Window
Bay Window
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
Living Living
2.4 X 3.9 2.4 X 3.9 MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
16
UNIT 6 UNIT 7 16 REQUIREMENTS
15 15
14 14 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
5,080
5,080
5,080
5,170
13 13
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
12 12
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
11,800
11,800
11 11
FOR MEMBER SIZES
10
9 Kitchen Kitchen
10
9
LEGEND
8 2.7 x 3.9 2.7 x 3.9 8 A/C AIR CONDITIONING AS SPEC. - INSTALLED
7 7 BY CONTRACTOR
6 6
AP 450 X450 REMOVABLE ACCESS
5 5
PANEL - LOCATION TO BE CONFIRMED ON SITE
BL CONC. BLOCK WALL TO STRUCTURAL ENG.
4 4
DETAIL - RENDER AND PAINT AS SPEC.
90
90
90
3 3
CF COLORBOND FLASHING TO DETAIL
2 2
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
1 1
CONC CONCRETE SLAB TO ENG. DETAIL
CPD CUPBOARD
DP 90mm DIA DOWNPIPE AS SPEC.
3,000
REFER TO DETAILS FOR TYPICAL FIXING
3,000
3,090
2.9 x 3 2.9 x 3
3,090
DRY CLOTHES DRYER
DW DISHWASHER
EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
WC
GUTTER BRACKETS @ MAX 900 CRS
WC
EGL EXISTING GROUNDLINE
F REFRIGERATOR
FW FLOOR WASTE
90
90
Balcony Balcony GD S.S GRATED DRAIN AS SPEC.
900
900
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
HP HOT PLATES AS SPEC.
900
900
HWU HOT WATER
MR MECHANICAL RISER
10 MW MICROWAVE
1,410 90 1,455 2,360 250 3,815 90 90 1,310 NGL NATURAL GROUND LINE
OV OVEN
250 P PANTRY
500 910 90 2900 90 900 900 90 2900 90 810 500 PGL PROPOSED GROUNDLINE
PTF POLISHED TIMBER FLOOR AS SPEC.
RHS RHS TO STRUCTURAL. ENG. DETAIL
910 2,405 1,500 250 1,500 2,505 810 RV "WIRILY BIRD" OR SIM. APPROVED
S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 20.03.14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Revised site plan + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16-01-14 Amend GFA CT Date:
UNITS 6-7, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT
PH: 0410 650 745
FIRST FLOOR
BSB No.: 1043429
F 24-01-14 Client request amendments CT NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
G 04.03.14 Amend design & balcony
H 20.03.14 Amend design & Areas
CT
CT
ECO REMOTE A.01.3 H
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 4
PEREGIAN BEACH VILLAS
ELEVATION LEGEND
UNITS 6-7, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
D-0 DOOR NUMBER
WD-0 WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
ALY ALYSNITE FLAT SHEETING
BLK BLOCKWORK
CN CONCRETE
FL
DP1 90Ø DOWNPIPE
EG1 EAVES GUTTER
FL
FC FIBRE CEMENT WITH 10mm EXPRESSED
Roof sheets @ 120 pitch fixed
0 JOINTS
Roof sheets @ 14 pitch fixed in MRS in accordance with FCC COMPRESSED FIBRE CEMENT
accordance with manufactures manufactures specification FL FLASHING
specification MRS
LVF FIXED ALUMINIUM LOUVRE
EG1 MRS METAL ROOF SHEETING
Ceiling Level Ceiling Level
EG1 ZINC ZINC CLADDING WITH STANDING SEAM
FL NGL NATURAL GROUND LINE
Bay window, with specified cladding fixed FL
PLY PLYWOOD WITH 10mm EXPRESSED
in accordance with manufactures JOINTS
specification Aluminium framed windows SPR SPREADER
2,740
2,740
fixed to manufactures SPT SPITTER
specifications
Ballustrade, in accordance with the BCA
Floor Level
and relevant Aus Standards Timber screen Floor Level
Ceiling Level Ceiling Level
Specified cladding fixed in
accordance with manufactures
Steel post in accordance with engineers
specification
specifications
2,740
2,740
Specified cladding fixed in accordance with
manufactures specification 1800H Timber Fence
Slab Level NGL NGL Slab Level
1 Left Elevation 1:100
Roof sheets @ 140 pitch fixed
MRS MRS
in accordance with
manufactures specification
Ceiling Level Ceiling Level
EG1 EG1 Bay window with specified horizontal
cladding fixed in accordance with
Ballustrade, in accordance manufactures specification
with the BCA and relevant Aus
2,740
2,740
Standards Aluminium framed bifold windows beyond
fixed to manufactures specifications
Fire rated wall in accordance
with manufacturers
Floor Level specifications Floor Level
Ceiling Level
Ceiling Level Specified vertical cladding fixed in
accordance with manufactures
Aluminium framed doors fixed
specification
to manufactures specifications
2,740
2,740
1800H Timber fence Steel post in accordance with engineers
specifications
Slab Level NGL NGL Slab Level
2 Rear Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 20.03.14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Revised site plan + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16-01-14 Amend GFA CT Date:
UNITS 6-7, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
F 24-01-14 Client request amendments CT NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
G 04.03.14 Amend design & balcony
H 20.03.14 Amend design & Areas
CT
CT
ECO REMOTE A.01.4 H
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 5
PEREGIAN BEACH VILLAS
ELEVATION LEGEND
UNITS 6-7, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
D-0 DOOR NUMBER
WD-0 WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
ALY ALYSNITE FLAT SHEETING
BLK BLOCKWORK
CN CONCRETE
FL DP1 90Ø DOWNPIPE
EG1 EAVES GUTTER
FL FC FIBRE CEMENT WITH 10mm EXPRESSED
Roof sheets @ 70 pitch fixed JOINTS
in accordance with MRS Roof sheets @ 140 pitch fixed in FCC COMPRESSED FIBRE CEMENT
manufactures specification accordance with manufactures FL FLASHING
MRS specification LVF FIXED ALUMINIUM LOUVRE
MRS METAL ROOF SHEETING
Ceiling Level EG1 Ceiling Level
EG1 ZINC ZINC CLADDING WITH STANDING SEAM
FL FL NGL NATURAL GROUND LINE
Aluminium framed windows Bay window, with specified cladding fixed PLY PLYWOOD WITH 10mm EXPRESSED
fixed to manufactures in accordance with manufactures JOINTS
specifications specification SPR SPREADER
2,740
2,740
SPT SPITTER
Ballustrade, in accordance
with the BCA and relevant Aus Ballustrade, in accordance with
Standards the BCA and relevant Aus
Standards Floor Level
Floor Level Ceiling Level
Ceiling Level
Timber screen
Specified cladding fixed in Timber post in accordance with engineers
accordance with manufactures specifications
2,740
2,740
specification
Specified cladding fixed in accordance with
1800H Timber Fence manufactures specification
Slab Level NGL NGL Slab Level
3 Right 1 Elevation 1:100
Fire rated wall in accordance
with manufacturers Specified vertical cladding
specifications
Aluminium framed windows
0
fixed to manufactures
Roof sheets @ 7 pitch fixed specifications
in accordance with MRS
manufactures specification
Ceiling Level Ceiling Level
EG1
Exposed rafters to roof system Specified vertical cladding
2,740
2,740
Timber screen Glass ballustrade, in
accordance with BCA and Aus
Floor Level standards Floor Level
Ceiling Level Ceiling Level
Specified cladding
Post in accordance with
2,740
2,740
1800H Timber fence
enfineers specifications
21 - 27 roller door Specified cladding
Slab Level NGL NGL Slab Level
4 Front Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 20.03.14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Revised site plan + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16-01-14 Amend GFA CT Date:
UNITS 6-7, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
F 24-01-14 Client request amendments CT NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
G 04.03.14 Amend design & balcony
H 20.03.14 Amend design & Areas
CT
CT
ECO REMOTE A.01.5 H
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES