Appendix H - Code Response · MCU23/0078
COMPLIANCE
PERFORMANCE OUTCOME ACCEPTABLE OUTCOME RESPONSE
✓//NA
B. Side boundaries 1.5 metre
setback up to 4.5 metres
height; 2 metres setback
between 4.5 metres and 7.5
metres height; and 2 metres
plus 500 millimetres for every
3 metres above 7.5 metres
height or part thereof; and
C. Rear boundary-first and second
storeys; 6 metres, third storey -
6 metres - if has an open
balcony with a minimum width
of 2.5 metres, otherwise 8
meters.
Editor's Note— For properties mentioned in section
(a)(ii) above, the minimum setback can be considered as
part of a separate urban design and planning study
endorsed by Council, to review land use, built form and
streetscape outcomes for these properties.
Other boundaries- The proposed development adopts setbacks to the side
3 metres from boundaries that adjoin land in a boundary adjoining the Environmental Management Zone
residential zone or Environmental to the west that exceed the 3 metre allowance.
Management and Conservation Zone,
otherwise 0.0 metres.
AO19.2 Childcare centres Not Applicable
All buildings, structures and outdoor play The proposed development is for a mixed-use
areas are set back at least 3 metres from all development that does not incorporate a Childcare Centre
site boundaries adjoining a residential activity use.
or NA
land included in a residential zone.
Editor's Note— If there is a conflict between minimum
boundary setbacks, the greater setback prevails.
Code Compliance Statements Page 10 of 87
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix H - Code Response.pdfRelated documentApplication case desk ↗
About this file
- File size
- 808 KB (small file)
- File type
No other editions are linked here.