COMPLIANCE
PERFORMANCE OUTCOME ACCEPTABLE OUTCOME RESPONSE
✓//NA
through the site linking Noosa Drive to Lanyana Way with Figure 7.2.5.4 (Noosa Junction Framework
which is to be constructed and dedicated to Council and Character Plan)
at no cost as part of the first stage of development
of the site.
Built Form
Height AO16.1 Complies with PO16
PO16 Buildings and other structures have a building The proposed development comprises of a mixed-use
Buildings and other structures: height of no more than: building incorporating commercial, retail and residential
(a) Noosa Junction - 12 metres; opportunities for the broader Noosaville catchment. In
(a) are low rise and have a visual bulk and
(b) Noosa Business Centre – accordance with the Noosa Planning Scheme, the proposal
architectural scale consistent with
i. if a site is identified as a gateway incorporates a maximum building height of 3 storeys, with
structures on adjoining or nearby land;
site on Figure 7.2.4.5 (Noosa residential multiple dwellings and short-term
(b) have the following maximum building
Business Centre Framework and accommodation being the only use provided on the third
height:
Character Plan), that portion of the storey level (cinema remains 2 storey with increased
i. for Noosa Junction three storeys;
site located within 50 metres of ceiling height).
ii. for the Noosa Business Centre two
storeys, except a gateway site or a the street frontage - 12 metres; or The residential component adopts a maximum building
mixed-use building incorporating a ii. are part of a mixed-use building height of approximately 13.6m fronting the main street
residential use which may be three incorporating residential uses, or in due to the pitch of the skillion roof design: however, the
storeys the High density residential ceiling height of the residential uses remains at or below
(c) do not visually dominate the street, precinct -12 metres; otherwise ✓ the 12m building height allowance.
surrounding spaces or the existing skyline; iii. 10 metres. The maximum overall building height of the mixed-use
and AO16.2 development is an area of roof associated with the
(d) preserve the amenity of surrounding proposed cinema component which has a peak roof height
Where excavation is required, the maximum
premises including privacy, views and access of RL26.35m, being 17.35m above the intended ground
portion of the exposed external façade of the
to sunlight. level. It is noted that this maximum building height is
building cannot exceed the respective building
centrally located above the northern car park area and not
heights in AO16.1.
located adjacent to any public use areas or thoroughfares
to ensure the building is not visually dominant from the
Editor's Note—refer to figure AP3-13A to measure street or civic spine level and does not impede views or
height in storeys. access to sunlight.
As per Appendix A– Architectural Plans, the building design
has been considered with a low-rise nature in mind,
providing building articulation and material variation to
improve human-scale and encourage integration with the
Code Compliance Statements Page 6 of 87