                                                       Environmental management and conservation                and the adjoining environmental management and
                                                       zone within a radius of 400 metres of the site.          conservation zone by manner of sealed pathways and a
                                                                                                                pedestrian bridge.
 Lighting                                              AO16                                                     Not Applicable
 PO16                                                  Lighting associated with the use is designed,            The proposed development does not adjoin a
 The obtrusiveness of lighting is minimised without    installed, operated and maintained in a manner      NA   residential use.
 unduly limiting the use, enjoyment or safety of       that does not unreasonably impact on the
 outdoor community activities.                         amenity of an adjoining residential use.

 Public toilets                                        AO17.1                                                   Complies with AO17.1
                                                                                                           ✓
 PO17                                                  Public toilets are located in high traffic areas.        Public toilets will be located in high traffic areas.
 Public toilets are designed and constructed to:       AO17.2                                                   Complies with PO17
     (a) ensure the safety of all people using them;   Features that may legitimise loitering, such as          Public toilets will be designed and constructed to an
         and                                                                                               ✓
                                                       seating or public telephones are not located             appropriate standard.
     (b) take advantage of informal surveillance       within 20 metres of toilet entrances.
         from adjoining uses and activities,
         discouraging non legitimate uses.             AO17.3                                                   Complies with AO17.1
                                                       Entrances to public toilets are visible from the         Entrances to public toilets will be visible from either
                                                                                                           ✓
                                                       street, footpath and other activity areas on the         the street or civic activity areas.
                                                       site or adjoining sites.

 Major Infrastructure
 PO18                                                  AO18.1                                                   Complies with AO18.1
 Development is sufficiently separated from            Buildings and structures (including swimming             The mixed-use development does not incorporate
 infrastructure including electricity infrastructure   pools, sheds, tennis courts and outbuildings) are   ✓    buildings or structures within overhead electricity
 and substations to minimise the likelihood of         not constructed under overhead electricity               transmission lines or within easements.
 nuisance or complaint.                                transmission lines, or within easements.

                                                       AO18.2                                                   Not Applicable
                                                       Development adjacent to or within 50 metres of a         The proposed development is not located adjacent to
                                                       substation, major electricity infrastructure or          or within 50metres of a substation, major electricity
                                                       major utility incorporates noise attenuation        NA   infrastructure or a major utility.
                                                       measures such that noise levels do not exceed
                                                       5db(A) above background noise level internal to
                                                       community buildings measured in accordance
                                                       with AS1055.



Code Compliance Statements                                                                                                                  Page 67 of 87

Used in these records

About this file

File size
808 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix H - Code Response.pdf · 808 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.