                                                                                                                                       COMPLIANCE
 PERFORMANCE OUTCOME                                          ACCEPTABLE OUTCOME                                                                  RESPONSE
                                                                                                                                       ✓//NA
 For the Major centre zone the plot ratio of a building                                                                                            The mixed-use development has approximate plot ratios
 does not exceed:                                                                                                                                  of 0.61 in the Village Mixed Use (5D) Precinct and 0.53 in
     (a) for Noosa Junction 1.9:1 excluding Lot 54                                                                                                 the High Density Residential (5E) Precinct, which is below
            RP139776 (Noosa Fair), where the plot ratio                                                                                            the allowance for each precinct in PO18 and considered to
            is not greater than:                                                                                                                   be appropriate for the proposed development.
         i.       0.8:1 for the first 2,000m² of site area;                                                                                        The part of the site situated within the High density
                  plus                                                                                                                             residential precinct provides a ratio of at least three small
        ii.       0.3:1 for the balance of the site area in                                                                                        dwellings to every one other dwelling, and adopts a plot
                  excess of 2,000m²;                                                                                                               ratio of consistent with the precinct intent, as identified
     (b) for the Noosa Business Centre:                                                                                                            above.
         i.       Showroom precinct 0.8:1                                                                                                          The proposed redevelopment/upgrades to the existing
        ii.       Business park precinct 0.8:1                                                                                                     Noosa Civic building in the Retail Precinct does not provide
       iii.       Retail precinct 0.5:1;                                                                                                           for any additional floor space or use areas and therefore
       iv.        Village mixed use precinct 1.9: 1;                                                                                               does not result in any change to the plot ratios established
        v.        High density residential precinct:                                                                                               for this facility.
                A. 0.65:1 for sites up to and including
                     7,000m²; or
                B. 0.6:1 for sites over 7,000m²; or
                C. where development provides a ratio
                     of at least three small dwellings to
                     every one other dwelling, does not
                     exceed:
                      I.     0.75:1 for sites up to and
                             including 7,000m2; or
                     II.     0.7:1 for sites over 7,000m2.
 Setbacks                                                     AO19.1                                                                               Complies with PO19
 PO19                                                         Buildings and structures comply with the                                             The proposed development adopts large (approximately 6
 Buildings and other structures are appropriately             following minimum boundary setbacks:                                                 metres to OMP and 7.6m to wall) setbacks to the adjoining
 designed and sited to:                                       Frontage                                                                             roundabout to the north achieving the 4 metres allowance
                                                                                                                                           ✓       for the ground and second storey. All walls along the
     (a) provide for users of the premises as well as             (a) Noosa Junction:
                                                                       i.   Where shown as having primary active street frontage                   western boundary achieve the 4 metre setback
         preserve the visual and acoustic amenity of                        in Figure 7.2.5.4 (Noosa Junction Framework and                        requirement with only minor deviations from the
         adjoining and nearby properties;                                   Character Plan) no setback required for the ground
                                                                            floor, second storey and third storey provided the third               compliant 4m with outermost projections of roof
     (b) provide adequate distance from adjoining                           storey has an open balcony to any street frontage with
                                                                            a minimum width of 2.5 metres, otherwise a setback of                  overhangs and screening encroaching into the setback to
         land uses;                                                         2 metres for the third storey;                                         the western most boundary. It is considered that due to


Code Compliance Statements                                                                                                                                                      Page 8 of 87

Used in these records

About this file

File size
808 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix H - Code Response.pdf · 808 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.