Original source · versioned page text
MCU10/2083 Development Application part 2 - Attachment 6 - Noise Impact Assessment Report
Proposed Commercial Development 37 Gibson Street Noosaville ENVIRONMENTAL NOISE IMPACT ASSESSMENT 26906 R06 37 Gibson Rd Noosaville ENV © TTM Consulting Pty Ltd 2010 3. EQUIPMENT The following equipment was used to record ambient noise levels in the vicinity of the site: ARL EL316 Environmental Noise Monitor (SN# 16-707-016); and BSWA Technology Co. Ltd CA106 Acoustical Calibrator (SN # 44095). The environmental noise monitor holds current NATA Laboratory Certification and was calibrated before and after the monitoring session with no significant drift from the reference signal recorded. 4. METHODOLOGY 4.1. Unattended Noise Monitoring An ARL EL316 environmental noise monitor was placed in the vicinity of the site at 1 Keel Court to measure the ambient noise levels. The microphone was in a position considered representative of the noise environment experienced by residents located east of the site and approximately 1.4 metres above ground level. The unattended noise monitor was set to record noise levels from the 15th to the 23rd of September, 2010 as follows: “A” weighting; “Fast” response; and 15 minute statistical interval. The statistical interval was chosen to allow application of AS/NZS 2107:2000 ‘Acoustics – Recommended Design Sound Level and Reverberation Times for Building Interiors’. Refer to Figure 3 for the unattended noise monitoring location. Page 6
See the original
The page text is free to read. Viewing or downloading an original file needs an account.