site plan

of 1

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
 

 

DRAWING SIZE — Al

 

HEIGHT DATUM

LOT 1 ON RP 229384
Level Datum AHD
Smiths Rd, Tinbeerwah

Survey information provided by
KEVIN HOLT CONSULTING

 

=

2

 

 

PROPOSED
RETAINING
WALLS

   

LEGEND

+189

— Sw/eEx

EXISTING SURFACE SPOT LEVELS.

INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE

INDICATES EXISTING SEWER LINE

INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS

INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS

INDICATES STORMWATER DRAIN EXISTING
AS NOTED

 

  

 

www.dialbeforeyoudig.com.au

SAS DIAL 1100

‘Wy BEFORE YOU DIG

 

 

 

  
  
 
  

4

\ \

PROPOSED,

 

SHED \
20mx1 4m .

     
  
 
      
      
     

 

 

AREA NOT
SURVEYED

 

 

 

=
\Y
e

 

SITE PLAN — PROPOSED SITE PLAN

Scale 1: 500

 

ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE

 

 

KE
EX. SWPT
EX. SWMH
EX. SMH
EX. SCP
E.0.B.
K&C
N.S.L.
FH.
TP
EP.
KERB
RCEW
SV
W.M

 

PROPOSED
POOL

“PROPOSED —
HOUSE
LOCATION

EFFLUENT DISPOSAL
AREA (BY OTHERS)
PROPOSED

RETAINING

WALLS

0 5 10m

PO

1:250 @ Al
1:500 @ AS

Rev 10.06.16

  

EXISTING STORMWATER PIT
EXISTING STORMWATER MANHOLE
EXISTING SEWER MANHOLE
EXISTING SEWER CONNECTION POINT
EXISTING EDGE OF BITUMEN
EXISTING KERB & CHANNEL
NATURAL SURFACE LEVEL

FIRE HYDRANT

TELSTRA PIT

ELECTRICAL PILLAR

EXISTING KERBING

REINFORCED CONCRETE END WALL
STOP VALVE

WATER METER

 

 

 

 

 

A SETBACK DIMENSIONS ADDED 13.08.25
Revision Description Date
Issue:

FOR APPROVAL

 

DO NOT SCALE FROM THIS DRAWING

The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.

 

O

SCG HOLDINGS PTY LTD Tid

Unit 1/11 Project Ave,
Noosa Heads

Ph (07) 5455 5604
email:[email protected]

web:www.scg-engineers.com
aptgcompany ‘ABN 68 669 675 790

 

Title:

PROPOSED SITE PLAN

 

Project

27 SMITHS ROAD,

 

 

 

 

TINBEERWAH
Date: June 25 Drawn LR Design TH
Checked: Drg No. Rev.
Pioragon (~~ (0482 -OW1.2| A

 

 

 

 
Log in to download the original file

site plan.pdf · 1.3 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.