Council archive · source document
Approved Plan OPW19-0021 · OPW19/0021
Plans and drawings: the text below has words only, no drawings.
- NOOSA COUNCIL APPROVED PLAN OPW19/0021 28 FEB 2019 [OCR of page images] 100mm| Omm 100mm | 50_ | 40_ | 30_ | 20 | 10 omm HYDRAULIC SERVICES ALTERATIONS - DUPLEX, 3 CORSAIR CRESCENT, 3 CORSAIR CRESCENT, SUNRISE BEACH, QUEENSLAND, 4567 Lot Sunshine Coast Regional Council PROJECT NOTES General Notes 1. ALL INSPECTION OPENINGS TO BE BROUGHT TO THE SURFACE & CAPPED WITH A BOLTED TRAP SCREW IN A CONCRETE SURROUND TO LOCAL GOVERNMENT APPROVAL. THE CONTRACTOR |S OBLIGATED TO INSPECT THE SITE & BE SATISFIED AS TO THE CONDITIONS UNDER WHICH THE WORK WILL BE CARRIED OUT PRIOR TO THE SUBMISSION OF A TENDER OFFER. DO NOT SCALE DRAWINGS, REFER TO ARCHITECTURAL DRAWINGS FOR ALL SET-OUT DIMENSIONS. THE CONTRACTOR SHALL ALLOW TO SUPPLY & INSTALL ALL SANITARY FIXTURES, TAPWARE & ASSOCIATED ACCESSORIES. REFER TO ARCHITECTURAL. SPECIFICATION FOR SCHEDULE LAYOUTS OF SERVICE LINES, PLANT AND EQUIPMENT SHOWN ON THE DRAWINGS ARE DIAGRAMMATIC ONLY EXCEPT WHERE FIGURED DIMENSIONS ARE PROVIDED OR CALCULABLE. NO WARRANTY IS GIVEN TO THE COMPLETENESS OR ACCURACY OF EXISTING SERVICES INFORMATION WHETHER DOCUMENTED OR OTHERWISE. WHERE CONNECTION IS REQUIRED TO EXISTING SERVICES THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE PRECISE LOCATION AND DEPTH OF THE EXISTING SERVICE CONNECTION POINT PRIOR TO THE INSTALLATION OF ANY ASSOCIATED WORKS THE CONTRACTOR SHALL CO-ORDINATE ALL PIPEWORK WITH THE OTHER TRADE SERVICES PRIOR TO COMMENCEMENT OF ANY WORK. ALL PIPES SHALL BE ADEQUATELY SUPPORTED & SECURED TO ADJACENT WALLS OR SLABS. SUPPORTS SHALL BE GALVANIZED MILD STEEL 'UNISTRUT' CHANNEL COMPLETE WITH PURPOSE MADE GALVANIZED SPRING NUTS, FRAMING, FITTING & PIPE CLAMPS FOR EACH PIPE. ALL COPPER PIPES SHALL BE SEPARATED FROM SUPPORTS BY 2mm MINIMUM THICK PVC STRIP OR SIMILAR APPROVED MATERIAL. THE CONTRACTOR SHALL SUPPLY & INSTALL ALL SANITARY FIXTURES SHOWN ON THE DRAWINGS OR NECESSARY FOR THE COMPLETION OF THE PROJECT. ALLOW FOR THE SUPPLY & FIXING OF ALL FIXTURES, BOLTS, BRACKETS, PUTTY, MASTIC, SILICON FILLERS, CEMENT & SUNDRY MATERIALS NECESSARY FOR EACH INSTALLATION INCLUDING ALL CONNECTIONS TO DRAINS, WATER SERVICES ETC. GENERALLY IN ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS. ALLOW FOR ALL BENDS, SETS & INSTALLING SUFFICIENT UNIONS, FLANGES & ISOLATING VALVES FOR SATISFACTORY REMOVAL OF PIPING & FITTINGS FOR MAINTENANCE OR REPAIRS TO PRODUCE AN INSTALLATION TO THE APPROVAL OF THE SUPERINTENDENT WHETHER SUCH ITEMS ARE SHOWN ON DRAWINGS OR SPECIFIED. ALLOW FOR THE COMPLETE SUPPLY & INSTALLATION OF TAPS & SUNDRY MATERIALS NECESSARY FOR THE INSTALLATION & CONNECTION IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. THE HYDRAULIC SERVICES CONTRACTOR SHALL BE RESPONSIBLE FOR CO-ORDINATING WITH MECHANICAL A/C SERVICE ON-SITE. CONTRACTOR TO SUPPLY ON COMPLETION ALL WARRANTIES, TECHNICAL DATA, TESTING CERTIFICATES, COMPLETION & COMPLIANCE CERTIFICATES PRIOR TO HANDOVER. SEAL PENETRATIONS WITH A SYSTEM CONFORMING TO AS4072.1 A SEPARATE HYDRAULIC SERVICES SPECIFICATION FORMS PART OF THIS DOCUMENT PACKAGE AND SHALL BE READ IN CONJUNCTION WITH THESE DRAWINGS CONTRACTOR TO CONFIRM EXISTING PIPE SIZES PRIOR TO CONNECTION OF NEW SERVICES Authority Requirements 1. THESE DOCUMENTS MUST BE READ IN CONJUNCTION WITH THE STAMPED APPROVED PLANS AND PLUMBING DRAINAGE AND COMPLIANCE PERMIT CONDITION (INCLUDING AMENDMENTS). ALL PLUMBING AND DRAINAGE WORK OR ON-SITE SEWERAGE WORK MUST COMPLY WITH THE COUNCILS LOCAL LAWS AND POLICIES AND OTHER RELATED DEVELOPMENT PERMIT CONDITION. THE CONTRACTOR SHALL PAY ALL FEES IN CONNECTION WITH APPROVALS, UTILITY PROVIDER CONSTRUCTION COSTS, TESTS & INSPECTIONS, ETC. THE CONTRACTOR SHALL CARRY OUT ALL THE NECESSARY TESTING OF THE SERVICES SHOWN ON THE DRAWINGS AS REQUIRED BY THE RESPECTIVE AUTHORITIES. OBTAIN CERTIFICATES FROM THE RELEVANT AUTHORITIES INDICATING SATISFACTORY COMPLETION OF SERVICES & HAND OVER TO THE SUPERINTENDENT BEFORE APPLICATION FOR CERTIFICATE OF PRACTICAL COMPLETION. IF ANY DOUBTS EXIST AS TO WHETHER A SECTION OF THE DESIGN IS ABLE TO COMPLY WITH THE RELEVANT AUTHORITY'S REGULATIONS, THE SUPERINTENDENT SHALL BE NOTIFIED PRIOR TO COMMENCEMENT OF ANY WORKS. NO CONSIDERATION OF CLAIM FOR REDUNDANT WORK SHALL BE GIVEN IF THE SUPERINTENDENT |S NOT NOTIFIED. CONTRACTOR TO ALLOW ALL COST FOR PREPARATION OF 'AS CONSTRUCTED DRAWINGS' DRAWN TO THE SAME STANDARD AS APPROVED PLAN & SUBMIT TO LOCAL AUTHORITY PRIOR TO COMMENCEMENT OF FINAL INSPECTION 1 1. Stormwater THE WHOLE OF THE STORMWATER DRAINAGE WORKS SHALL BE IN ACCORDANCE WITH THE NATIONAL CONSTRUCTION CODE (PLUMBING CODE OF AUSTRALIA), ASINZS 3500.3:2015, & THE LOCAL GOVERNMENT WORKS DEPARTMENT GUIDELINES & REGULATIONS, & THE QUEENSLAND DEVELOPMENT CODE. ALL DOWNPIPES AND STORMWATER DRAINAGE SHALL BE FREE OF LEAKS WHEN TESTED IN ACCORDANCE WITH AS/NZS 3500.3:2015 (SECTION 10). SUPPORT WATER STORAGE TANKS IN SUCH A MANNER THAT NO LOAD IS TRANSMITTED TO ANY OF THE ATTACHED PIPES. FOR ROOF CATCHMENT IN CONNECTION WITH RAINWATER TANKS: 4.1. INSTALL RAINWATER SYSTEMS & EQUIPMENT IN ACCORDANCE WITH STANDARDS AUSTRALIA HB 230-2008 "RAINWATER TANK DESIGN & INSTALLATION HANDBOOK". 4.2, PROVIDE "GUTTER GUARD" OR SCREENED DOWNPIPE RAINHEADS HAVING 4 - 6mm SCREEN MESH TO PREVENT LEAVES FROM ENTERING THE DOWNPIPE. SCREEN MESH TO BE FIRE RESISTANT, COLOUR MATCHED AND COMPATIBLE WITH ROOF AND GUTTER MATERIAL AND PROFILE. 4.3. ALL DRAINAGE PIPEWORK AND FITTINGS ON THE INLET SIDE OF THE STORAGE TANK SHALL BE PVC CLASS DWV HAVING WATER TIGHT JOINTS FORMED WITH THE USE OF SOLVENT CEMENT AND PRIMING FLUID (UNO). PROVIDE MOVEMENT CONTROL JOINTS IN ACCORDANCE WITH MANUFACTURES RECOMMENDATIONS TO ACCOMMODATE ANTICIPATED MOVEMENT. (REFER GEOTECHNICAL REPORT). BEDDING FOR PIPELINES TO BE WASHED 5mm SCREENING WITH A MINIMUM 150mm BELOW AND ABOVE PIPES. WHERE PIPES ARE LAID IN FILL, THE FILLING SHALL BE CARRIED OUT IN LAYERS NOT EXCEEDING 300mm (LOOSE) IN DEPTH AND SHALL BE COMPACTED UNTIL THE COMPACTION IS NOT LESS THAN 95% OF THE MATERIALS MAXIMUM COMPACTION WHEN WHEN TESTED IN ACCORDANCE WITH AS 1289 (MODIFIED COMPACTION). TESTING SHALL BE CARRIED OUT AFTER EACH ALTERNATE LAYER AND CERTIFICATES MADE AVAILABLE CERTIFYING THAT THE REQUIRED COMPACTION HAS BEEN ACHIEVED. Materials WATER SUPPLY PIPE SIZES SPECIFIED ON THESE DRAWINGS ARE BASED ON CALCULATIONS FOR PIPES HAVING EQUIVALENT DIMENSIONAL AND FLOW CHARACTERISTICS TO THAT OF TYPE B COPPER TUBE, WHERE ALTERNATIVE MATERIALS ARE USED AN EQUIVALENT PIPE SIZE APPROPRIATE TO THE MATERIAL BEING USED SHALL BE SELECTED. STORMWATER uPVC DWV * PIPE AND FITTING MATERIALS MAY BE SUBSTITUTED PROVIDED ALTERNATIVE MATERIALS ARE AUTHORIZED FOR USE IN ACCORDANCE WITH THE PLUMBING CODE OF AUSTRALIA (PCA) & WRITTEN APPROVAL OF HYDRAULIC SERVICES CONSULTANT. FOR WATER SERVICES REFER ALSO: AS/NZS3500.1 SECTION 2 AND APPENDIX B - ACCEPTABLE PIPE AND FITTINGS. NOOSA COUNCIL APPROVED PLAN OPW19/0021 28 FEB 2019 LINETYPES - PROPOSED — — —_ STORMWATER LINETYPES - EXISTING sw STORMWATER SYMBOLS =—— SERVICE No. IN ( ST) —— SERVICE NAME N07 ———_ SERVICE SIZE C END CAP w TUNDISH C DROPPER ° RISER / WASTE POINT ABBREVIATIONS CSWP Civil Stormwater Pit DP Down Pipe e Existing eSwP Existing Stormwater Pit eSWRG Existing Stormwater Road Gully G Gully GL Ground Level IL Invert Level oP Overflow Pit ORG Overflow Relief Gully POLY Polythene PVC Polyvinyl Chloride RL Reduced Level SCRC Sunshine Coast Regional Council sD Spoon Drain sDO Spoon Drain Outlet SL Surface Level sw Stormwater Drain SWMH Stormwater Manhole UNO Unless Noted Otherwise UPVC Unplasticised Polyvinyl Chloride US/IL Up Stream Invert Level SUNRISE BEACH LINETYPES - PROPOSED ——— —__ STORMWATER LINETYPES - EXISTING sw STORMWATER SYMBOLS Te |] TT ; ee TaN = sce i tlh Lin ——_ SERVICE NAME NY, —~—_ SERVICE SIZE C END CAP gi TUNDISH Cc DROPPER ° RISER / WASTE POINT ec NA ABBREVIATIONS | i js cswP > Civil Stormwater Pit DP. : Down Pipe e + Existing eSWP : Existing Stormwater Pit eSWRG + Existing Stormwater Road Gully G : Gully GL : Ground Level IL : Invert Level ee oP : Overflow Pit _ a T ORG : Overflow Relief Gully — POLY - Polythene CORSAIR CRESCEN Pvc : Polyvinyl Chloride RL : Reduced Level SCRC : Sunshine Coast Regional Council sD : Spoon Drain sDO : Spoon Drain Outlet SL : Surface Level LOCALITY PLAN SW + Stormwater Drain SCALE 7-900. ATSHEET AI. SWMH : Stormwater Manhole SCALE: 1:20 ATSHEET At UNO : Unless Noted Otherwise UPVC : Unplasticised Polyvinyl Chloride US/IL : Up Stream Invert Level : : : — : : ow ‘00g PVC % 1 100 MIN 1008 Pvc % 4-100 MIN ina ow {000 PVC % “ my ba ow 100@ PVC % 1100 MIN EX. EX. sosumP ||| ||| |/ || 250SuMP s a {| % I 71 ne To FS ou m4 a) GV errr sR Ve a. Vo || —_—? i — ~ N007 5 ul ° tl — mq — = u z 7 ~ 4 | S33 | L I} 4 Pojpod Pp a < Po | Po -] S | | | | Ss 3 | | | - | x | | | | S LoS al eDF-) Ge Eo LS J 8 ow = = — =F 100 100 —— —il 1 8 y “TN | KU [ & a | ON Cepr new [XJ € £ Dd] New ene) : Now | ssosuin ES . we oe 250 SUMP | z Nu VA Ss | \arr gin 4 : H----4 2! s sea 2 z > g | _ Ss ae So = “3 \ . s| 8 S J J a / Ss \ =. 400 MIN . one pee Y 8 " ° 5 | nyo ve 000 PVC" pvc% 11000 ADMIN oy sw EX. : 4508 pve th 1:100 MIN wo / 250 SUMP ee | } “ Le — EX. i] w= _ 450 SUMP o\—" LE za = 8 x 9% a Q Fr Trl FX GROUND FLOOR PLAN DRAINAGE LAYOUT SCALE: 1:200 AT SHEET A1 70 100mm 21.02.19 | pb [COUNCIL ISSUE T 02 | Pcp 15.02.19 | DD | PRELIMINARY REVIEW Tot [ oc DATE [ svase | DESCRIPTION [rew wo AUTH. ARCHITECT \ BUILDING DESIGNER ANNETTE WARNER PTY LTD PO Box 1234, NOOSA HEADS, QUEENSLAND PHONE: (07) 5447 4893 CLIENT HYDRAULIC CONSULTANT MRP HYDRAULIC & FIRE SERVICES CONSULTANTS PTY LTD A: 1/63 Annerley Road, Woolloongabba, QLD PO Box 8143, Woolloongabba, QLD, 4102 9 Files - saved by : Susan - plot by : Susan Fox P: (07) 3846 4379 F: (07) 5443 1136 E: [email protected] W: mrp.com.au QBCC: 1137134 ABN: 23 126 270 326, m BRISBANE oCAIRNS oc SUNSHINE COAST a TOWNSVILLE VERIFIED BY. | DATE DESIGNER | DATE ANDREW GARDEN 15.02.19 PROJECT DESCRIPTION & ADDRESS ALTERATIONS - DUPLEX, 3 CORSAIR CRESCENT, SUNRISE BEACH 3 CORSAIR CRESCENT, SUNSRISE BEACH, QUEENSLAND, 4567 HYDRAULIC SERVICE SHEET DESCRIPTION NOTES, LEGEND, LOCALITY PLAN, & GROUND FLOOR DRAINAGE LAYOUT AM Ll NOT FOR APPROVAL, TENDER OR CONSTRUCTION PROJECT NUMBER SCALE SHEET SIZE 19-0107 Noted A rescent, Sunshine Beach\X_MRP\Doc_Current Drawin ‘SHEET NUMBER. H-101 REVISION NUMBER 02 100mm
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plan OPW19-0021.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.