Original source · versioned page text
MCU10/2083 Information Request Response 37 Gibson Rd Noosaville
Very large file: it may take a few minutes
The original of this document is very large (15.5 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Proposed Commercial Development 37 Gibson Street Noosaville ENVIRONMENTAL NOISE IMPACT ASSESSMENT 26906 R09 37 Gibson Rd Noosaville ENV 0 TTM ConsuImg Pty Ltd 2010 8.2. Management principles To mitigate potential noise impacts at receivers, we recommend applying the following management principles: • Waste collection shall be limited to the daytime period, between 7am and 6pm. • All shop doors on the southern and western building facades shall remain closed when not in use for immediate access. • Staff shall not congregate at the rear of the shops during the evening period. • All shop doors on the southern and western building facades shall be fitted with automatic closing mechanisms. 8.3. Onsite Mechanical Plant Noise Included in the design is a I lm parapet that will provided additional attenuation to Receivers 2-5 from of rooftop plant noise. Because detailed plant selections are not available at this stage, it is not possible to carry out a detailed examination of the ameliorative measures that may be required to achieve the noise targets. Plant will be acoustically treated to achieve the criteria detailed in Section 6.2 to prevent noise emissions from adversely impacting the surrounding properties. This may include selecting the quietest plant possible, or treating the plant equipment with enclosures, barriers, duct lining and silencers, etc if required to comply with the assessment criteria. Experience with similar projects indicates that it would be possible to achieve the Council requirement with appropriate treatment of the plant. This treatment would be determined at the Building Approval/Construction Certificate stage. A mechanical plant noise assessment should be conducted by a suitably qualified acoustic person once plant selections are finalised; and compliance tests conducted after the equipment is installed to ensure compliance with the criteria. Such measures should also be conditioned in the Development Approval. Page 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.