PLANNING & ENVIRONMENT COMMITTEE MEETING AGENDA 7 SEPTEMBER 2021
Page 13 of 143
SITE DETAILS
CO LO g Sa RESPONSIBILITY CANNOT BE TAKEN FOR SITE LEVELS
CO war €& 600h400d concrete revetment wall ~ 110 glass panels and spiggots over THEREFORE THE BUILDER SHOULD VERIFY THESE LEVELS
lO oO FF 20.000 BEFORE COMMENCING ANY WORK
s+ 2 & _—SSSSSSSSSSaaSSSSSSSSqQqQ5QqSqSq 4 sf IES
Rg oy ”. (aEENeR mano eae, CUT AND FILL, LEVELS SHOWN ON THIS PLAN ARE APPROXIMATE
rab) CO «x g aD 6600 otk i INTERPRETATIGN, AND MAY VARY TO FINISHED LEVELS ON SITE
— CO ' Ee +3 vi Laer grass 3s eek AT COMMENCEMENT AND COMPLETION OF WORKS.
— QO_ o gy | existingtimber stars “Nhe Ao” 5 “7
= 2 s| eS Seyi ee Lat PLATFORM IMMEDIATELY SURROUNDING RESIDENCE TO
om «s By fs its ey FALL AWAY FROM RESIDENCE AT A SLOPE OF 1 IN 15MIN
oO ($1 TM hh ie
YU p) = coon eh sr
oO c_ 3 ZT existing 1250dx max 200 wetedae DRIVEWAY SLOPE NOT 10 EXCEED A MAX 1 VERTICAL TO
oO ws = 4HORIZONTAL APPROX
oO existing pool 8
c!- =z 1000MAX HIGH TIMBER RETAINING WALLS TO HAVE 85mm DIA, AG. PIPE
o> . (DISCHARGE TO STORMWATER) + GRADED GRANULAR BACK FILL
a = q Ne BEHIND AND TO BE CONTAINED WITHIN SITE
Oo w existing 1200h glass balustradng RETAININING WALLS EXCEEDING THIS ARE TO BE ENGINEERED ALSO
ao 7? NEE DISPOSE SEWERAGE IN ACCORDANCE WITH LOCAL AUTHORITY
) , = ; PREPARED DRAINAGE PLAN
ws DISCHARGE ALL STORMWATER TO COUNCIL SWATER SYSTEM
— ee i — ISCHAI Ju WwW INCIL 5
“oo 7. j —7 (DOWNPIPE DESIGN, SIZE AND LOCATION BY BUILDER AND ROOFING
existing — REQUIREMENTS, AND MAYBE ADJUSTED TO SUIT SITE CONDITIONS.
a. N residence 7 DOWNFIPES
oO 8 XY 7 aS SODIA OR 10x50 DOWNPIPES TO STORMWATER PIPES 100m MIN
— s / COVER 1 IN 100MIN FALL
wk 9 j-
N él rience Berea eee TERMITE PROTECTION
—_
BUILDER TO PROVIDE TERMITE CONTROL SYSTEM IN ACCORDANCE
WITH AS 3660 1
TERMITE PROTECTION GENERALLY SHALL BE BY GROUND FLOOR SLAB
AS BARRIER AND EXPOSED EDGE OF SLAB AS VISUAL BARRIER
. TERMI MESH OR SIMILAR COLLARS TO SLAB PENETRATIONS
a TERMITE RESISTENT (HAZARD LEVEL H2} TIMBER FRAMING GENERALLY
SNE BUILDER TO PROVIDE ACCESS FOR CLEAR VISUAL INSPECTIONS TO THE
<> : ENTIRE PERIMETER OF THE HOUSE, AND THE EXPOSED EDGE OF CONCRETE SLABS
ee > \
Pa I eo t f NZ ENERGY EFFICIENCY
< i Titty A I
| a Ss fae ALL TOILETS TO BE INSTALLED WITH 94-5 DUAL FLUSH CISTERNS OR BETTER
! \ a g ALL SHOWER HEADS TO HAVE CERTIFIED AAA WATER CONSERVATION RATING
= ; “4 ALL TAPS TO HAVE CERTIFIED AAA WATER CONSERVATION RATING
| | Tene ENERGY EFFICIENT LIGHTING TO BE USED FOR MIN OF 80% OF FLOOR AREA
| | EB |_| | HOT WATER SYSTEM TO BE GAS BOOSTED SOLAR HOT WATER SYSTEM
LET, - [ | { a7 ; | {OR OTHER APPROVED) OF SIZE TO SUIT REQUIREMENTS,
ah A tI SST Wy be te | SENERAL
a Oe ee i
Pep ee ee eS SE =f ‘ 3 ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH
if? Bae a SN = | Pa THE BUILDING CODE OF AUSTRALIA
, Jaa ae | tS Spb See eee THE BUILDING ACT 1975
Nene F cago y aa a EE ae STANDARD BUILDING REGULATION 1993
IF BUILDING IS IN A BUSHFIRE AREA Bee sng PER eel see TT BUILDING REGULATION 2008
ABAL REPORT MUST BE OBTAINED AND MUST . a aaa seme QDC QUEENSLAND DEVELOPMENT CODE
COMPLY WITH AS 3659-2009 UNDER BAL XX He j seeeee nae AS 1684-2006 TIMBER FRAMING CODE
PS De aT
NOTE TO BUILDER: ALL TIMBER FRAMED WALLS TO WET AREAS TO BE LINED WITK FC
WCS TO BE A MIN CLEAR FINISHED WIDTH OF 900mm
IF ANY DISCREPANCIES ARISE IN THE CERTIFICATION , DOORS TO WC'S TO HAVE LIFT OFF HINGES
PROCESS, AND BUILDING WORKS HAVE COMMENCED Wo vation ofsewering SMOKE ALARMS TO BE PROVIDED AS PER BCA & AS3786
NO RESPONSIBILITY IS TAKEN FROM THE COMPLETED. MASONARY CONSTRUCTION TO BE IN ACCORDANCE WITH AS3700
DESIGN AND DRAFTING |T IS AREQUIRED PART OF THE ALL WET AREA FLOORS AND WALLS TO BE PROTECTED AS PER CLAUSE 3.8 1 BCA
BUILDING AND PLANNING OF INDIVIDUAL PROJECTS TO T O P S A | L S P L A ( E BALUSTRADING TO BE 100MIN ABOVE FINISHED FLOOR LEVEL AND HAVE
CONFIRM COUNCIL PLANNING SCHEME AND BUILDING 126mm MAX SPACING IN BALUSTERS
COMPLIANCE, PROVICE DPC'S AS PER CLAUSE 3.3.4 BCA (a
PROVIDE FLASHINGS AS PER CLAUSE 33.4, 35.1 &353BCA oO
NOTE INSTALLATION OF ALL EXTERNAL MATERIALS BY SUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NOC —
_ EXISTING: POOL FENCE | CLIENT: BUILDER: MANDY'S DRAFTING ONLY SHEET: 1 of 3 | DATE: ISSUE NO: wo
sy REVETMENT WALL C/O RG STRATEGIC TOWN PLANNING NA PH: 0403 481 474 SCALE: 1:200 |19MAY 2021 RG-2021-A +=
f- NOTE. THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE. BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION Ww
tick bee. WITHENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITHSee the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.