Original source · versioned page text
Tewantin and Doonan Locality Code
COLUMN 1 COLUMN 2 ASSESSMENT
SPECIFIC OUTCOMES PROBABLE SOLUTIONS
Height
O7 S7.1 Complies with the Probable Solutions
Building and other structures Buildings and other structures do not exceed a The building height is a maximum of 6.0m for the
a) present a building height consistent with maximum building height of special care and the administration building will be
structures on adjoining and surrounding land; a) for the Business Centre Zone 12m; or 8m in height, which is below existing height.
b) do not exceed a maximum building height of b) for the Visitor Mixed Use Zone -
i. for the Business Centre Zone 3 storeys; i) northern side of Hastings Street
or A. within 7m of the Hastings St alignment
ii. for the Vistor Mixed Use Zone 6m
A. northern side of Hastings Street B. balance area of site - 15m with a 12m
within 7m of the Hastings Street alignment 2 presentation to the beach; or
storeys; or ii) southern side of Hastings Street
balance area of site 4 storeys with a 3 storey A. within 10m of the Hastings Street or
presentation to the beach; or Noosa Drive alignments 6m
B. southern side of Hastings Street B. balance area of site 15m; or
within 10 m of Hastings Street or Noosa Drive c) for Attached Housing Zone 12m; or
alignments 2 storeys; or d) for any other zone 8m
balance area of site 4 storeys; or
iii. for Attached Housing Zone 3 storeys; or
iv. for any other zone 2 storeys;
c) do not visually dominate the street or
surrounding spaces;
d) preserve the amenity of surrounding land
e) respect the scale of surrounding vegetation;
f) respond to the topography of the site by
stepping down the slope or supported above
ground level;
g) maintain a mature vegetated skyline.
Setbacks
O8 S8.1 Complies with the Probable Solution
Buildings and other structures are appropriately Buildings and structures comply with the minimum From Schedule 1 Minimum Boundary Setbacks,
designed and sited to - setbacks identified in Schedule 1 Minimum the requirements for Multiple Housing Type 3
a) provide amenity for users of the premises as Boundary Setbacks. (Retirement and special needs), the requirements
well as preserve the visual and acoustic are:
amenity of adjoining and nearby properties; Frontage 6m for 2 storey buildings or for 3 storey or 4
b) preserve any existing vegetation that will storey buildings 6m for the first 2 storeys and 10m for
buffer the proposed building; any storey thereafter