Technical Note
Address:          1 Coral Sea Court, Sunshine Beach

Client:           John & Jane Turner



1.       Background

Mr and Mrs Turner propose a driveway, to serve the above property, to be located on Whale Drive, as
opposed to Coral Sea Court.

Whale Drive is a local road, with a speed limit of 50km/hr and a very low traffic volume. The road is
approximately 6.0m in width and has a longitudinal gradient of 11.7% at the location of the proposed
driveway access.

Tod Consulting were requested to undertake an engineering review of the proposed driveway
location, in support of an application to Noosa Council.

Our assessment has included:
     •   Conversation with Mr Turner;
     •   Conversation with Mark Lewis of Noosa Council;
     •   Review of Layout Drawing prepared by Design to Detail (Drawing No. 1424 attached).
     •   Site visit and determination of sight distances;
     •   A review of the proposed driveway location based on current standards;
     •   Turn path analysis;
     •   Conversation with Andrew Matthews of Unitywater; and
     •   Preparation of this Technical Note to summarise our findings.

This Technical report and the accompanying sketch (SK01) have been prepared to support an
application to Noosa Council for approval of the alternate driveway location.

2.       Assessment of Proposed Driveway

We have assessed the proposed driveway location on Whale Drive against the requirements of
AS2890 – Parking Facilities – Part 1: Off-Street Car Parking and summarise our findings below.

a)       AS2890.1 - Section 3.2.3 – Access Driveway Width

Table 1.1 classifies domestic parking as User Class 1A.

Based on User Class 1A, Local Road and less than 25 parking spaces, reference to Table 3.1
categorises this access facility as Category 1.

Table 2.3 states a Category 1 access driveway is to be a minimum of 3.0m in width, which the owner
can comply with.




                                                                                                   1
14717_1 Coral Sea Court, Sunshine Beach - Technical Note_Revision A
Full text of the other 4 pages

Page 2

b)       AS2890.1 - Section 3.2.3 – Access Driveway Location

Section 3.2.3 of this code states a driveway should not be located within 6.0m of the tangent point of
an intersection street. The proposed driveway would be located approximately on the tangent point
and therefore does not comply with this requirement.

c)       AS2890.1 - Section 3.2.4 – Sight Distance at Access Driveway Exits

The code states that access driveways are to be located in a manner that provides adequate entering
sight distance for traffic exiting the property to view traffic on the frontage road i.e. Whale Drive.

The driver sight distances are measured, in each direction, from a point 2.5m from the road edge.
When checking the sight distances, the driver’s eye height and the height of the object (approaching
vehicle) were taken to be 1.15m above the road surface.

Based on a posted speed limit of 50km/hr on Whale Drive, a domestic property access requires a
distance (Y) along the frontage road of 40m. When looking right the sight line is measured to the
edge of the frontage road. When looking left the sight line is measured to the centre of the road.

Tod Consulting have undertaken an inspection of the property and undertaken a physical check of the
available sightlines. A summary of the sight distances are tabulated below.

      AS2890.1 - Section 3.2.4 Requirements                           Actual Sightlines available
                 40m (both directions)                                     70m to the right
                                                                            60m to the left

It is evident from the above that compliant sight distances can be achieved in both directions.

These actual sight lines can be seen in Photos 1 and 2.




                                                                                                    2
14717_1 Coral Sea Court, Sunshine Beach - Technical Note_Revision A

Page 3

      Photo 1: 70m Sightline to the Right (Silver Gull Court intersection located 45m away)




                   Photo 2: 60m Sightline to the Left (Lampost located 60m away)




                                                                                              3
14717_1 Coral Sea Court, Sunshine Beach - Technical Note_Revision A

Page 4

There are existing yellow no standing line markings, on both sides of the road, for a considerable
distance in each direction. This therefore prevents vehicles parking on-street and obstructing the
available sight lines.

It should be noted it is essential that no physical obstructions are erected within the sight line triangles
to ensure the safe operation of this driveway access.

3.       Safety

a)       Proximity to Intersection

As Coral Sea Court is a no through road there would be a very low volume of traffic utilising the
existing intersection.

Although the proposed driveway is located within the desirable 6.0m offset from the tangent point, it
could be considered beneficial that it is located on the through road of the intersection. Therefore,
approaching vehicles, from either direction have more than adequate sight lines to the proposed
driveway.

If the driveway was located on Coral Sea Court a vehicle could turn left from Whale Drive and have
very little advance warning or sight distance.

The proposed driveway location is on the approach side for vehicles on Whale Drive turning left into
Coral Sea Court. As such vehicles exiting from Coral Sea Court will not conflict with vehicles entering
and exiting the driveway.

b)       Vehicle Turnaround

The owner has agreed to provide a turnaround within the property to avoid the need to reverse onto
Whale Street when exiting the property. Therefore all exiting vehicles will be leaving in a forward
gear, which is a much safer manoeuvre. This avoids the need for a reversing vehicle to come to a
halt in the middle of the main road.

The previous garage / carport has been removed and undercover parking has been provided as
shown on sketch SK01.

The driveway configuration has been designed to allow vehicles to reverse from the garaging,
manoeuvre on site and exit the site in a total of 2 movements. The turning movements, as
demonstrated on SK01, have been undertaken using the template for a B85 vehicle (i.e. a large car).

c)       Driveway Grade

Due to the natural topography of the property a vehicle access onto Coral Sea Court would be much
steeper than the proposed access onto Whale Drive. The proposed driveway should therefore be
easier and safer to negotiate without the need for steep approaches to the main road.

4.       Existing Vegetation

As can be seen from sketch SK01 and the above photographs there is existing vegetation in the
vicinity of the proposed driveway, including a Hibiscus.



                                                                                                          4
14717_1 Coral Sea Court, Sunshine Beach - Technical Note_Revision A

Page 5

Where necessary this vegetation will either be trimmed or removed to ensure adequate sight lines. If
removed the Hibiscus will be replaced with another advanced growth species near the proposed
driveway, such as a Banksia or Acacia.

Ongoing maintenance of all vegetation will be necessary to ensure the future safe operation of this
driveway access.

5.       Existing In-Ground Services

It should be noted there is an existing fire hydrant and Telstra pit located within the road verge.

Unitywater have confirmed that they would approve the proposal provided the fire hydrant is cast into
the concrete driveway in accordance with their requirements (refer attached authorisation).

The Telstra pit will be located adjacent to the proposed concrete driveway and therefore is not
affected by these works. However, a timber bollard will be provided adjacent to this pit to avoid
accidental traffic loads.

6.       Conclusion

Whilst the proposed access is not located the desired distance from the intersection, Tod Consulting
believe the adequate sight lines, low speed environment and low volume of traffic would enable safe
operation of this driveway.

We present the above findings for your review and request your further consideration of a proposed
driveway access on Whale Court.


Prepared by



Greg Jackson (RPEQ 12825)
Tod Consulting Pty Ltd
16 December 2014




                                                                                                      5
14717_1 Coral Sea Court, Sunshine Beach - Technical Note_Revision A

Used in these records

About this file

File size
496 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

14717_1 Coral Sea Court, Sunshine Beach - Technical Note_Revision A-signed.pdf · 496 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.