Original source · versioned page text
MCU14/0056 Response to SARA - Consulting Report
The original of this document is very large (24.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 102, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnEN 858-1:2002 (E) EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using test data from reaction to fire tests. EN ISO 1172, Textile-glass-reinforced plastics — Prepegs, moulding compounds and laminates — Determination of the textile-glass and mineral-filler content — Calcination methods (ISO 1172:1996). EN ISO 1514, Paints and varnishes — Standard panels for testing (ISO 1514:1993). EN ISO 9377-2, Water quality — Determination of hydrocarbon oil index — Part 2: Method using solvent extraction and gas chromatography (ISO 9377-2:2000). 3 Terms and definitions For the purposes of this European Standard, the following terms and definitions apply. 3.1 light liquid liquid with a density no greater than 0,95 g/cm’, which is actually or practically insoluble and unsaponifiable 3.2 separator system arrangement comprising a separator (class |, class |I), a sludge trap and a sampling point 3.3 sludge trap part of the separator system where material settles, i. e. sludge, silt and grit, and which can be a separate unit or constructed with the separator as a combined unit 3.4 separator (class I, class I) part of the separator system, which separates light liquid from waste water and retains the light liquid 3.5 sampling point part of the separator system situated downstream of the separation process where samples can be taken of the waste water discharged from the separator 3.6 extension shaft component used to extend an opening in the separator system to finished level for inspection and maintenance purposes 3.7 nominal size (NS) number, without units, approximately equivalent to the maximum effluent flow in litres per second from the separator when tested in accordance with 8.3.3 3.8 separating zone zone, in which light liquid is separated from waste water in the separator 3.9 storage capacity for light liquids volume of separated light liquid, which can be held in the separator without the stored light liquid entering the inlet or outlet of the separator 3.10 automatic closure device mechanism, operated by the accumulated light liquid, which prevents discharge of the light liquid from the separator This is a licensed reproduction produced by SAI Global Ltd, an authorized distributor of British Standards 7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.