MCU14/0056 Response to SARA - Consulting Report
The original of this document is very large (24.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 108, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnEN 858-1:2002 (E) 6.3.2 Watertightness of components All components of a separator system (including joints, seals, connections and partitions) shall be watertight and the separator system including extension shafts shall be tested in accordance with 8.2. 6.3.3 Accessibility The separator system including the inlet and outlet areas of the sludge trap and separator shall be accessible for maintenance and inspection. Extension shafts and access openings shall be provided to allow the removal of light liquids and any settled material. Their dimensions shal! comply with the requirements for manholes and inspection chambers as given in EN 476. On separator equal to or greater than NS 10 there shall be at feast one access point in compliance with clause 7.3 of EN 124:1994. 6.3.4 Water seals Water seals shall be provided at the inlet and outlet of the separator. The depth of the water seal shall be a minimum of 100 mm. Where the separator and sludge trap are combined, the inlet seal may be provided either at the sludge trap or at the separator. 6.3.5 Pipes and pipe joints The minimum nominal diameters DN,,in of the inlet(s) and outlet(s) for the separator system shall be selected from table 2 and compatible with standardized pipe systems. Table 2— Pipe minimum nominal diametersDNwain Nominal size DN nin 2 up to and including NS 3 100 Over NS 3 up to and including NS 6 125 Over NS 6 up to and including NS 10 | 150 Over NS 10 up to and including NS 20 | 200 Over NS 20 up to and including NS 30 | 250 Over NS 30 up to and including NS 100 | 300 Over NS 100 400 a The nominal diameter can apply to either the internal or external pipe diameter. Provision shalt be made for possible ground movement and settlement when joining inlet, outlet and connection pipes. 6.3.6 Internal components Provision shall be made for cleaning the internal components using pressurized air or water. Parts which need to be removed for maintenance shall be accessible and easily removed. Any oil retained in the separator system shall be prevented from entering the outlet pipe. 6.3.7 Sludge traps Sludge traps shall be constructed with a flow-control device at the inlet to reduce the inflow velocity and provide a uniform flow pattern. This device shall be designed to avoid short circuits and allow sediments to settle. ‘This is a licensed reproduction produced by SAI Global Ltd, an authorized distributor of British Standards 43
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.