Original source · versioned page text
MCU14/0056 Response to SARA - Consulting Report
The original of this document is very large (24.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 123, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnEN 858-1:2002 (E) 8.3.3.1.2 Test apparatus The test apparatus shall be in accordance with: — figure 5 and 4 and table 4 for separators with a nominai size < NS 100 and — figure 5 and 6 for separators with a nominal size > NS 100. The supply pipe between the collecting chamber and the separator shall have the same nominal diameter DN as the inlet to the separator. For separators without combined sludge trap, having two inlet pipes, the supply pipe . close to the collecting chamber shall be divided into two branch pipes each having a Jength of 2m. The cross section of the supply pipe closest to the collecting chamber but before branching shall be equivalent to the total cross section of the two branch pipes. The test fluids shall be supplied by means of dosing pumps allowing appropriate flow control or by gravity. The flow rate shall be constant during the test. The outlet pipe(s) from the supply channel(s) shall be fitted with a stream regulating grid. The cross section of the outlet pipe(s) shall be totally and uniformly charged with water. The bottom(s) of the outlet pipe(s) from the supply channel(s) and light liquid supply pipe shall be at the same level. Table 4 — Dimensions Nomina! size of separator a; dp ds hy he h bh NS mm mm mm mm mm Up to 6 400 | DN125 | DN12 500 | 200 | 1500 | 450 Over 6 to 30 1000: | DN300 | DN 25 800 | 300 | 2500 | 900 Over 30 to 100 1000 | DN400 | DN40 | 1350 | 300 | 2500 | 900 Dimensions in millimetres 1 i a 2, 2 34 | 3 500max. Key 1 Wall of separator 2 Internal diameter = 12,5 3 Nominal diameter of outlet pipe of the separator DR Figure 5 — Sampling device This is a licensed reproduction produced by SAl Global Ltd, an authorized distributor of British Standards
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.