Skip to the record
Noosa’s premier civic archive.

Original source · versioned page text

MCU14/0056 Response to SARA - Consulting Report

of 321

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (24.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Original PDF page 133, section 1. The text section number identifies this passage in the reader.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
EN 858-1:2002 (E)

A.3.6 Example GC conditions
— Injection technique: ° Programmed temperature vaporisation (PTV)
— Injection temperature: 50 °C to 300 °C
— Injection volume: 1 LI (NOTE Larger volumes will give increased sensitivity)
*“— Column length: 30m
— Column internal diameter: 0,25 mm
— Liquid phase: DB 5 MS
— _ Pre-column: Deactivated fused silica capillary
— Carrier gas: Hydrogen (Hz)
— Carrier gas pressure: ~ 80 kPa

— Oven temperature programme: 40 °C for 5 min, 10 °C/min to 300 °C for 20 min

— Detector: Flame ionisation detector (FID)
— Detector temperature: 300 °C

— Make up gas: Nitrogen (Na)

— Make up gas flow: 25 ml

The system shall be able to integrate the whole chromatogram and compensate for the blank chromatogram.

The total peak area between n-decane and n-tetracontane shall be integrated. The integration begins immediately
at the end of the n-decane peak and ends immediately in front of the n-tetracontane peak. The signal level before
the solvent peak shall-be used as the baseline. The total peak area for the sample is measured and the area for a
blank chromatogram (spiked petroleum ether) is subtracted. This correction eliminates the effect of column
bleeding. The extract may be diluted to bring it within the calibration range. A blank chromatogram shall be run at
least once every ten samples. A check on the validity of the calibration shall be done with each series of samples
using an oil in petroleum ether standard with a concentration between 40 % and 80 % of the calibration range. The
result of the check solution shall be within 10 % of the calibration.

A.3.7 Calibration
The system shall be calibrated using a series of five external standards covering the required analysis range and a

blank. These standards are prepared in petroleum ether spiked with n-decane and n- tetracontane. The standards
shall be prepared by dilution of a stock standard (see Tables A.1 and A.2).

38 This is a licensed reproduction produced by SAI Global Lid, an authorized distributor of British Standards
Log in to download the original file

MCU14_0056 Response to SARA - Consulting Report.pdf · 24.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.