MCU14/0056 Response to SARA - Consulting Report
The original of this document is very large (24.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 133, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnEN 858-1:2002 (E) A.3.6 Example GC conditions — Injection technique: ° Programmed temperature vaporisation (PTV) — Injection temperature: 50 °C to 300 °C — Injection volume: 1 LI (NOTE Larger volumes will give increased sensitivity) *“— Column length: 30m — Column internal diameter: 0,25 mm — Liquid phase: DB 5 MS — _ Pre-column: Deactivated fused silica capillary — Carrier gas: Hydrogen (Hz) — Carrier gas pressure: ~ 80 kPa — Oven temperature programme: 40 °C for 5 min, 10 °C/min to 300 °C for 20 min — Detector: Flame ionisation detector (FID) — Detector temperature: 300 °C — Make up gas: Nitrogen (Na) — Make up gas flow: 25 ml The system shall be able to integrate the whole chromatogram and compensate for the blank chromatogram. The total peak area between n-decane and n-tetracontane shall be integrated. The integration begins immediately at the end of the n-decane peak and ends immediately in front of the n-tetracontane peak. The signal level before the solvent peak shall-be used as the baseline. The total peak area for the sample is measured and the area for a blank chromatogram (spiked petroleum ether) is subtracted. This correction eliminates the effect of column bleeding. The extract may be diluted to bring it within the calibration range. A blank chromatogram shall be run at least once every ten samples. A check on the validity of the calibration shall be done with each series of samples using an oil in petroleum ether standard with a concentration between 40 % and 80 % of the calibration range. The result of the check solution shall be within 10 % of the calibration. A.3.7 Calibration The system shall be calibrated using a series of five external standards covering the required analysis range and a blank. These standards are prepared in petroleum ether spiked with n-decane and n- tetracontane. The standards shall be prepared by dilution of a stock standard (see Tables A.1 and A.2). 38 This is a licensed reproduction produced by SAI Global Lid, an authorized distributor of British Standards
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.