Council archive · source document
Geotech Report · OPW26/0094
Project No. PG-10899 Page | 2 November 2023 Ref: PG-10899, 2023-10-16, GR VER 1 DD Sunnyside CD Sunnyside Pty Ltd – Geotechnical Investigation - Proposed Residence, 30 Mossman Court, Noosa Heads 2.0 METHODOLOGY The geotechnical investigation comprised the drilling and sampling of one (1) borehole to a depth of 9.0m, using a Compac 018 drilling rig fitted with 100mm solid flight augers, and one (1) hand auger across the proposed building area. Dynamic Cone Penetrometer (DCP) testing was conducted adjacent to the boreholes. The soil classification descriptions and field tests were carried out in general accordance with Australian Standards. AS 1726 Geotechnical Site Investigations AS 1289 Methods of Testing Soils for Engineering Purposes Borehole records, Dynamic Cone Penetrometer test results and a site plan showing the test locations are appended to the report. 3.0 SITE DESCRIPTION The site of the proposed development is located at 30 Mossman Court, Noosa Heads. The site was bordered by Mossman Court to the south, existing residences to the east and west, and a canal to the north. At the time of the investigation, the site was occupied by an existing two storey residence and detach single garage. The site was relatively level and drainage was considered poor to fair. Refer following aerial and site photographs for typical site conditions. AERIAL IMAGE