—— — S 3 LP. In the Planning and Environment Court No D44 of 2025 Held at: Brisbane Between: GYMPIE TERRACE PTY LTD ACN 163 150 409 Appellant [PLANNING AND ENVIRONME\ OURT | GUEENEL eA NOOSA SHIRE COUNCIL Respondent 19 JUN 2028 JUDGMENT Before Her Honour Judge McDonnell Date of Hearing: 5, 6 and 8 May 2026, and 19 June 2026 Date of Order: 19 June 2026 THIS MATTER having come on for hearing by way of Notice of Appeal filed by the Appellant on 28 April 2025 against conditions imposed on the approval of a development application for a material change of use for Short Term Accommodation (16 Units) and Food and Drink Outlet (Development Application) with respect to land situated at 203-207 Gympie Terrace, Noosaville in the State of Queensland, described as Lot 7 on RP347727 and Lot 2 on RP138699; UPON HEARING the Counsel for the Appellant and the solicitor for the Respondent; IT IS ADJUDGED THAT: 1. The appeal is allowed in part; 2. The decision of the Respondent of 20 March 2025 to approve the Development Application subject to conditions be set aside and replaced with a decision to approve the Development Application subject to the development conditions attached hereto (contained in pages 1 to 56 and marked “A”). ) Atm 14 [6/26 ORDER P&E Law Filed on behalf of the Appellant 4/59 The Esplanade Maroochydore QLD 4558 Form PEC-7 : : 07 5479 0155 [email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalThe download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.
Full text of sections 2 to 22 (of 65)
Section 2
Filed on 19 June 2026
Filed by: P&E Law
Service address: 4/59 The Esplanade, Maroochydore QLD 4558
Phone: 07 5479 0155
Email: [email protected]
Registrar
Section 3
“A”
PLANNING
When Conditions Must Be Complied With
1. Unless otherwise stated, all conditions of this Decision Notice must be complied with prior
to the use commencing, and then compliance maintained at all times while the use
continues.
Currency Period
2. This development approval lapses if the use has not happened by 20 March 2031 unless
an application to extend the currency period is approved by Council.
Approved Plans
3. Development authorised by this approval must be undertaken generally in accordance with
the Approved Plans listed in the tables below. Plans must be amended to incorporate the
amendments listed within the table below and resubmitted to Council prior to the issue of
any Development Permit for Operational Works*
The following plans require amendment.
Plan No. Rev. Plan/Document Name Date
CD 2.01 C C Basement Plan prepared by Arkos Architects 20.02.2025
Amendments Additional information in relation to the ‘end of trip’ facilities are to be
included on the plan.
A total of 29 car parking spaces are to be shown for the Short term
accommodation use on either Basement Plan or Ground floor plan.
CD 2.02 XR2 XR2 Ground Floor Plan prepared by Arkos
Architects
10.04.2026
Amendments The plan is to be amended to demonstrate that a minimum of 1.0 metre
width of soft landscaping can be provided to all street frontages particularly
around proposed urban infrastructure in Albert Street.
The plan is to demonstrate a minimum of 375 square metres of
landscaping is provided on site excluding outdoor dining and paved areas.
Provide an updated calculation which separates all landscaping areas
individually to comprise 375 square metres of landscaping.
The plan is to amend the number of ‘Tide’ structures to maximum of 5,
with each structure to provide shade to a seat, with the structures to be
built within the site boundary.
Carparks 2 - 12 are to be amended to accommodate landscaping
infrastructure in accordance with the Landscaping Works conditions of this
approval. Some of carparks 2 – 12 may be shortened and designated as
‘small car bays’ if necessary to accommodate required landscaping, but
only if those car bays utilise the 0.6m overhang referred to on the approved
ground floor plan.
The ground floor plan is to accommodate on site refuse collection in
accordance with the engineering requirements stipulated in condition 61.
CD 2.03 C C Level 01 Plan prepared by Arkos Architects 26.02.2025
CD 2.04 C C Level 02 Plan prepared by Arkos Architects 26.02.2025
CD 2.05 C C Level 03 Roof Tce Plan prepared by Arkos 26.02.2025
Architects
Page 1 of 12 1
Section 4
CD 2.06 C C Roof Plan prepared by Arkos Architects 26.02.2025
CD 3.01 B B Elevation 01 – Gympie Tce / North prepared by 26.02.2025
Arkos Architects
Amendments The rooftop pergola structure is to be reduced to be no more than 2.2
metres in height above roof level. The pergola is not to be roofed or
covered with an impervious material.
The horizontal roof over stairs providing access to the roof top is not
approved and is to be amended to be reduced in height and to follow the
gradient of the stairs to reduce the appearance of a roofed area.
Any wall/s around the edge of the roof top terrace or on the roof area are a
maximum of 1.2 metres in height. A privacy wall is permitted along the
eastern side of the ‘Roof Terrace 2’ up to 1.7 metres in height.
Note on plan that the windows in the northern side of the rooftop pools and
(facing Gympie Terrace) are to be constructed from clear glazing or similar
(e.g. acrylic).
North and south facing walls located between the terrace areas (pergola
for U202 and pool for U203) are to be reduced in height (so as not to
extend beyond the internal roof structure) or removed, subject to detailed
design.
CD 3.02 B B Elevation 02 – Thomas St / West prepared by 26.02.2025
Arkos Architects
Amendments The rooftop pergola structure is to be reduced to be no more than 2.2
metres in height above roof level. The pergola is not to be roofed or
covered with an impervious material.
The horizontal roof over stairs providing access to the roof top is not
approved and is to be amended to be reduced in height and to follow the
gradient of the stairs to reduce the appearance of a roofed area.
Any wall/s around the edge of the roof top terrace or on the roof area are a
maximum of 1.2 metres in height. A privacy wall is permitted along the
eastern side of the Roof Terrace 2 up to 1.7 metres in height.
Note on plan that the windows in the northern side of the rooftop pools
and (facing Gympie Terrace) are to be constructed from clear glazing or
similar (e.g. acrylic).
North and south facing walls located between the terrace areas (pergola
for U202 and pool for U203) are to be reduced in height (so as not to
extend beyond the internal roof structure) or removed, subject to detailed
design.
CD 3.03 B B Elevation 03 – East / Albert St prepared by 26.02.2025
Arkos Architects
Amendments The rooftop pergola structure is to be reduced to be no more than 2.2
metres in height above roof level. The pergola is not to be roofed or
covered with an impervious material.
The horizontal roof over stairs providing access to the roof top is not
approved and is to be amended to be reduced in height and to follow the
gradient of the stairs to reduce the appearance of a roofed area.
Any wall/s around the edge of the roof top terrace or on the roof area are a
maximum of 1.2 metres in height. A privacy wall is permitted along the
eastern side of the ‘Roof Terrace 2’ up to 1.7 metres in height.
Note on plan that the windows in the northern side of the rooftop pools
and (facing Gympie Terrace) are to be constructed from clear glazing or
Page 2 of 12 2
Section 5
similar (e.g. acrylic). North and south facing walls located between the
terrace areas (pergola for U202 and pool for U203) are to be reduced in
height (so as not to extend beyond the internal roof structure) or removed,
subject to detailed design.
CD 3.04 B B Elevation 05 – South prepared by Arkos 26.02.2025
Architects
Amendments The rooftop pergola structure is to be reduced to be no more than 2.2
metres in height above roof level. The pergola is not to be roofed or
covered with an impervious material.
The horizontal roof over stairs providing access to the roof top is not
approved and is to be amended to be reduced in height and to follow the
gradient of the stairs to reduce the appearance of a roofed area.
Any wall/s around the edge of the roof top terrace or on the roof area are a
maximum of 1.2 metres in height. A privacy wall is permitted along the
eastern side of the ‘Roof Terrace 2’ up to 1.7 metres in height.
Note on plan that the windows in the northern side of the rooftop pools
and (facing Gympie Terrace) are to be constructed from clear glazing or
similar (e.g. acrylic).
North and south facing walls located between the terrace areas (pergola
for U202 and pool for U203) are to be reduced in height (so as not to
extend beyond the internal roof structure) or removed, subject to detailed
design.
‘Metal cladding with a profiled design’ to the southern elevation is not
approved. An alternative design treatment is required to be developed
and shown on the elevation.
A suggested alternative could involve greater use of lightweight natural
materials / articulation of the façade / green wall to result in a more
subtropical and sympathetic visual presentation.
*(Refer to Advisory Note)
Nature and Extent of Approved Use
4. The approved development consists of Food and Drink outlets and Short Term
Accommodation (16 Units) as shown on the approved plans.
5. The total number of bedrooms that are available for guest accommodation must not exceed
36 bedrooms.
6. The Food and Drink outlets as shown on the approved plans are not to exceed, outdoor
dining (220m²), internal use area (451m²) and gross floor area 699m².
7. The Food and Drink outlet use on the premises must not operate outside the hours of:
a. Sunday to Thursday: 6am to 10pm; and
b. Friday and Saturday: 6am to 12:00 midnight.
The requirements of this condition must be included in the Community Management
Statement for any body corporate for the subject site.
Performance Bonds
8. Security in the form of a cash bond or trading bank guarantee to the sum of $50,000 must
be submitted to Council, to secure performance of all conditions of this approval, prior to
the issue of a Development Permit for Operational Works. The cash bond or trading bank
guarantee will be returned on performance of the conditions of approval less any costs
incurred by Council in respect of enforcing performance of this permit. Council reserves the
right to call upon the bond or guaranteed sum to effect compliance with conditions.
Page 3 of 12 3
Section 6
An applicant for a development application may make an agreement with an assessment
manager, referral agency or other person to establish the responsibilities, or secure the
performance, of a party to the agreement about a development condition.
Building Form and Development Appearance
9. The two Pergolas shown on the approved plans at the roof level are not to be roofed or
covered in an impermeable membrane and are not to exceed 2.2 metres in height.
10. The maximum height of the development must not exceed the building heights shown on
the approved plans, as amended by conditions of this approval, above ground level.
11. Certification must be submitted to Council from a Registered Cadastral Surveyor (Qld)
which certifies that the buildings do not exceed the maximum height requirement of this
Decision Notice.
12. External design features, including the extent of fixed or operable screens fronting all
streets, materials, colours and finishes must be shown on the Approved Plans and
submitted to Council for written approval from the Development Assessment Manager prior
to the issue of Building approval. No inclusions or alterations are made without approval in
writing by Council.
13. Additional detailed plans and interior elevations showing appearance and design
treatments of internal view corridors highlighted by Council in the Internal Views bundle
(NSC mark-up) to be submitted to Council prior to the issue of any Operational Works
Permit. The design of these areas must not result in an increase in the gross floor area of
the development.
14. All deck and balcony areas must not be enclosed with shutters, louvres, glass panelling or
the like thus remaining as open structures.
15. All balustrades to decks and balcony areas must be open or transparent.
16. All air conditioning units or other mechanical equipment must be fully enclosed or screened
such that they are not visible from the street frontages nor adjoining properties.
17. Any security screens on the premises consist of grille or translucent screens and not solid
shutters, screens or roller-doors.
18. All mechanical equipment and other service infrastructure, with the exception of a fire
booster, Energex pad mount transformer and bio-retention basin, located on the site must
be:
a. located not less than 2 metres from a property boundary;
b. fully enclosed or screened such that they are not visible from the street frontages nor
adjoining properties. Where screened by landscaping, landscaping beds must be at
least 1.5 metres wide.
19. No part of the site may be used for outdoor storage of materials.
Amenity
20. The operation of the approved use must not unreasonably detrimentally affect the
residential amenity (including but not limited to noise, amplified music, overlooking, light
spill or odour) enjoyed by surrounding residents or cause a nuisance, including a noise
nuisance.
21. Deleted
22. Deleted
23. Service vehicle movements associated with non-residential uses on the premises
(including loading and unloading) must not occur outside the hours of 6am to 6pm, 7 days
per week. The requirements of this condition must be included in the Community
Management Statement for any body corporate for the subject site.
Page 4 of 12 4
Section 7
24. Communal outdoor recreation facilities including swimming pools, spas and sports courts
are not to be used between the hours of 10:00 PM and 6:30 AM the following day.
Noise
25. Written certification is required from a suitably qualified person confirming that sound
pressure levels from all mechanical plant and equipment comply with the following:
a. Air-conditioning and Refrigeration
i. 7am to 10pm: Maximum level allowable = background + 5dB(A)
ii. 10pm to 7am: Maximum level allowable = background + 3dB(A)
b. Pumps, Service Room
i. 7am to 7pm: Maximum level allowable = background + 5dB(A)
ii. 7pm to 10pm: Maximum level allowable = background + 3dB(A)
iii. 10pm to 7am: No audible noise.
26. The certification must be submitted to Council, which certifies that operational noise from
any fixed plant and equipment complies and with the requirements of this Decision Notice.
Lot Amalgamation
27. All separate, adjoining lots that form part of this application shall be amalgamated into one
undivided allotment in accordance with the Plan of Survey submitted for registration at the
Land Titles Office. Proof of title being issued for the amalgamated lot shall be submitted to
Council prior to the issue of the Development Permit for Building Works.
Easements
28. Deleted
29. Unless otherwise agreed in writing by the relevant service provider, any public or third party
infrastructure located on the subject site must be placed within an easement registered
against the title of the property.
30. Any easement proposed under Condition 29 must be designed in accordance with the
planning scheme and granted at no cost to the Grantee. Where the Grantee is Council or a
service authority, the easement documentation must be in accordance with the Grantee’s
standard easement terms. Draft easement documentation must be submitted to Council
for endorsement.
31. All works must be kept clear of any existing or proposed easements on the subject land,
unless agreed otherwise in writing by the Grantee.
Community Management Statement
32. Any proposed Community Management Statement required for the development pursuant
to the Body Corporate and Community Management Act 1997 must be submitted to
Council for endorsement at the same time as submission of the Building Format Plan (or
similar) to Council for compliance assessment.
33. All clauses and by-laws of the proposed Community Management Statement must accord
with the requirements of this Decision Notice and, in particular, must include the following
additional clauses:
a. The units must be used for Short term accommodation for tourists and travellers only.
Street Identification
34. The street address of the development must be clearly visible and discernible from the
primary frontage of the site by the provision of a street number and, where appropriate, the
building name.
Page 5 of 12 5
Section 8
External Works – Gympie Terrace
35. Gympie Terrace must be upgraded for the length of its frontage to the subject site. The
works must be undertaken in accordance with an Operational Works approval and must
include in particular:
a. the existing footpath between back of kerb and property frontage is to be upgraded
with exposed coloured aggregate finish for the full width to the approval of the Design
Coordinator - Infrastructure services.
b. removal of the existing property accesses and reinstatement of the kerb, to match the
balance of the site frontage;
c. the verge area is to include street trees in accordance with the Landscaping Works
and Retention of Existing Trees as part of this approval.
d. the provision of 7 on-street carparks as shown on the Approved Plans (as amended),
in a manner that does not disadvantage adjacent properties or the function and safety
of the local road network – all proposed 7 on-street carparks must be line marked in
accordance with AS2890.05, include a minimum width of 2.1m measured from kerb
invert and achieve a minimum separation of 1 metre between all driveway crossovers
and kerb tangent points to not disadvantage existing sight lines;
e. the provision of 6 on-street motorbike parks as shown on the Approved Plans (as
amended), in a manner that does not disadvantage adjacent properties or the
function and safety of the local road network – all proposed 6 on-street motorbike
parks must be line marked in accordance with AS2890.05 and achieve a minimum
separation of 1 metre between all driveway crossovers and kerb tangent points to not
disadvantage existing sight lines; and
f. the existing kerb ramp on the eastern side of Gympie Terrace must be upgraded in
accordance with Council’s standard drawing NSD-9006E.
Condition 35 (a) is imposed pursuant to s128 of the Planning Act 2016 being necessary
trunk infrastructure identified by Council’s LGIP to service the development.
Conditions 35 (b, c, d, e and f) are imposed pursuant to s145 of the Planning Act 2016
being non-trunk infrastructure.
External Works – Thomas Street
36. Thomas Street must be upgraded for the length of its frontage to the subject site. The
works must be undertaken in accordance with an Operational Works approval and must
include in particular:
a. The verge between back of kerb and property frontage is to be upgraded with
exposed coloured aggregate finish for the full width to the approval of the Design
Coordinator - Infrastructure services.
b. Existing mature vegetation within the road reserve must be retained and protected;
c. area is to include street trees in accordance with the Landscaping Works and
Retention of Existing Trees as part of this approval;
Condition 36 (a) is imposed pursuant to s128 of the Planning Act 2016 being necessary
trunk infrastructure identified by Council’s LGIP to service the development.
Conditions 36 (b and c) are imposed pursuant to s145 of the Planning Act 2016 being non-
trunk infrastructure.
External Works – Albert Street
37. Albert Street must be upgraded for the length of its frontage to the subject site. The works
must be undertaken in accordance with an Operational Works approval and must include in
particular:
Page 6 of 12 6
Section 9
a. a 1.5-metre wide concrete pedestrian footpath within the road verge for the entire
length of the site’s frontage to Albert Street. The footpath’s width can be reduced (to
a minimum of 1.2 metres), only in locations where a 1.5-metre wide footpath would
impede on minimum clearances from services (i.e., light poles) or result in the
creation of trip hazards for pedestrians;
b. removal of the existing property accesses and reinstatement of the kerb, footpath and
verge area to match the balance of the site frontage, including the provision of topsoil
and turf where the existing verge is grassed;
c. the verge area is to include street trees in accordance with the Landscaping Works
and Retention of Existing Trees as part of this approval;
d. the provision of 6 on-street carparks as shown on the Approved Plans (as amended),
in a manner that does not disadvantage adjacent properties or the function and safety
of the local road network. All proposed 6 on-street carparks must be line marked in
accordance with AS2890.05, include a minimum width of 2.1m measured from kerb
invert and achieve a minimum separation of 1 metre between all driveway crossovers
and kerb tangents point to not disadvantage existing sight lines; and
e. the provision of 4 on-street motorbike parks as shown on the Approved Plans (as
amended), in a manner that does not disadvantage adjacent properties or the
function and safety of the local road network. All proposed 4 on-street motorbike
parks must be line marked in accordance with AS2890.05 and achieve a minimum
separation of 1 metre between all driveway crossovers and kerb tangent points to not
disadvantage existing sight lines.
Condition 37 (a, b, c, d, and e) are imposed pursuant to s145 of the Planning Act 2016
being non-trunk infrastructure.
Site Access and Driveways
38. A sealed access driveway must be provided from Thomas Street to the development. The
works must be undertaken generally in accordance with Arkos Architects, Ground Floor
Plan Traffic Engineer mark-ups as requested, drawing no. 2.02 XR2 dated 10 April 2026,
other than with respect to the motorcycle bays on Thomas Street noted to be removed, two
(2) of which must be retained.
39. A sealed exit driveway must be provided to Albert Street. The works must be undertaken
generally in accordance with Traffic Transport Plus, Swept Path (MRV 8.8m) – EGRESS,
Drawing number FIGURE F2, Revision 4, dated 16 April 2026 and Traffic Transport Plus,
Swept Path (MRV 8.8m) – EGRESS, Drawing number FIGURE F3, Revision 4, dated 16
April 2026.
Car Parking
40. 56 car parking spaces and 10 motorcycle spaces as shown on the Approved Plans (as
amended) must be provided and marked on the site. The works must be undertaken in
accordance with an Operational Works approval, generally in accordance with the
Approved Plans (as amended) and must include in particular:
a. 29 of the on-site car parking spaces (as set out on the Approved Plans, as amended)
shall be clearly marked as being for Short-term accommodation uses and shall be
accessible at all times. The balance of the on-site car parking spaces (as set out on the
Approved Plans, as amended) shall be clearly marked as being for Food and Drink
Outlet uses and shall be accessible at all times;
b. pedestrian routes in accordance with the conditions of this Decision Notice;
c. 1 disabled parking space/s within the total; and
d. dimensions, User Class, crossfalls and gradients in accordance with Australian
Standard AS2890: Parking Facilities.
Page 7 of 12 7
Section 10
41. All car parking areas and access driveways must be maintained exclusively for vehicle
parking and manoeuvring and kept in a tidy and safe condition at all times.
42. Directional signage must be provided to direct visitors and customers to the car parking
spaces provided on site.
Service Vehicles
43. Service vehicle parking, manoeuvring and standing spaces must be provided on the site.
The works must be undertaken in accordance with an Operational Works approval,
generally in accordance with the Approved Plans (as amended).
Security Access to Carpark
44. Where access to the carpark is proposed to be restricted by a security gate, provision must
be made for queuing of vehicles clear of the roadway while waiting for the security gate to
open.
45. Where a secure carpark services a commercial use on the site, the security gate must
always remain open while commercial uses on the site are open for business. The
requirements of this condition must be included in the Community Management Statement
for any body corporate for the subject site.
Pedestrian and Bicycle Facilities
46. Pedestrian and bicycle facilities must be provided for the development. The works must be
undertaken in accordance with an Operational Works approval and must include in
particular:
a. the development must include 19 bicycle spaces as shown on the approved plans;
and
b. adequate separation of all specific pedestrian routes from vehicle access and
manoeuvring areas, and clear demarcation by pavement marking, signposts or
changes in surface materials or levels.
Public Safety
47. During operating hours, all parking areas, pedestrian areas and entrances/exits to all
stairwells, lifts, foyers and public toilets must be well lit with vandal resistant lighting and
with intensities to satisfy the requirements of Australian Standard AS1158 “Public Lighting
Code”. Lighting must be designed to reduce the contrast between shadows and well-lit
areas. In particular, appropriate security lighting must be provided in the location of the
bicycle/ scooter parking and bin storage area.
48. After hours access to loading docks, storage areas and the basement carpark (including
the vehicle ramp and all stairwells) must be restricted by a security gate, lockable doors
and/or other suitably appropriate means. The basement carpark must be kept closed and
locked at all times while the use is not operating.
Stormwater Drainage
49. The site must be provided with a stormwater drainage system connecting to a lawful point
of discharge. The works must be undertaken in accordance with an Operational Works
approval, be generally in accordance with RECOR’s Stormwater Management Plan
(20230025-SWMP01, Rev. 01) dated 30 May 2024 and the Queensland Urban Drainage
Manual.
50. A stormwater quality treatment system must be provided for the development. The works
must be undertaken in accordance with an Operational Works approval and Water by
Design’s Bioretention Technical Design Guidelines 2014, and must include in particular:
a. stormwater quality treatment devices of a size and location generally in accordance
with those shown in RECOR’s Stormwater Management Plan (20230025-SWMP01,
Rev. 01) dated 30 May 2024.
b. bioretention device(s) which:
Page 8 of 12 8
Section 11
a. are design generally in accordance with IPWEAQ Standard Drawing DS-073,
DS-075 and DS-076; and
b. are provided with a free-draining outlet from the sub-soil drainage system.
51. The development shall be provided with approved permanent signage to educate the public
on the function of the bioretention basin. The wording for the signage for the bioretention
basin is to include: “BIORETENTION BASIN – This bioretention basin reduces the pollution
of our waterways by reducing the amount of heavy metals, litter, suspended solids, and
nutrients discharged to the Noosa River”.
52. All bioretention basins must be maintained in accordance with Water by Design’s
Maintaining Vegetated Stormwater Assets (Version 1) 2009. Records of all maintenance
activities undertaken must be kept and made available to Council upon request.
53. All proprietary stormwater quality treatment devices must be routinely checked, serviced
and cleaned in accordance with the manufacturer’s recommendations. Records of all
maintenance activities undertaken must be kept and made available to Council upon
request.
Landscaping Works
54. The development site must be landscaped. The works must be undertaken in accordance
with an Operational Works approval and the Noosa Plan for that specific area and must
include in particular:
a. the landscape frontage works shown on the referenced documents are to achieve a
minimum of 1.0 metre width of landscaped area (clear of retaining structures) to all
frontages and a minimum overall site landscaped area of 10%.
b. landscaping adjacent carparks 02-11 inclusive, must incorporate 6 shade trees (1
tree per 2 car parks). The use of underground structural soil cells to create a
minimum of 5 square metres of suitable growing medium / area is required for each
tree.
c. vegetated screening of any electrical transformers, bin storage areas and the like
from the road frontage
d. provision of 1 street tree within the road reserve for every 8 metres of road frontage
55. All landscape works must be established and maintained in accordance with the approved
design for the life of the development, and in a manner that ensures healthy, sustained and
vigorous plant growth. All plant material must be allowed to grow to full form and be
refurbished when its life expectancy is reached.
Retention of Existing Trees
56. The existing trees within the road reserve and identified for retention on the referenced
must be retained in accordance with an Arborist Report (or part thereof) prepared by a
qualified person* and endorsed through an Operational Works approval. Should any
existing trees be required to be removed they shall be replaced with a suitably sized
specimen, bag size 200 litre min and approved by Council’s Design Coordinator –
Infrastructure Services.
*(Refer to Advisory Note)
57. Prior to the prestart meeting, a bank guarantee or a bond of $20,000 must be lodged as
security for the protection of the trees identified for retention in the conditions of this
approval. The bond:
a. may be drawn upon by Council in its entirety if any one tree identified for retention is
damaged to the point where the tree cannot be saved (as confirmed by the project
arborist and agreed in writing by Council)
b. will be returned upon practical completion of all the operational works relating to this
development.
Page 9 of 12 9
Section 12
Earthworks and Retaining Walls
58. The site is contained on the Environmental Management Register. Prior to the issue of any
Operational Works approval, the applicant must provide a ‘Site Suitability Statement’
confirming the site is suitable for the proposed use.
59. All earthworks and associated retaining structures/batters, both above and below ground,
both temporary and permanent, must be undertaken in accordance with an Operational
Works approval, be generally in accordance with RECOR’s Bulk Earthworks Layout Plan
(020, Rev. D) dated 7 February 2025 and Bulk Earthworks Sections Prepared by RECOR
(021, Rev. D) dated 7 February 2025 and contained entirely within the subject site unless
written permission from the respective landowner(s) is provided to Council. All earthworks
must ensure that adjacent properties and associated infrastructure is not disadvantaged by
additional flows or adverse impacts on the functionality of access driveways and carparks.
60. All retaining walls must be designed and constructed in accordance with the planning
scheme and must be certified by an RPEQ where exceeding 1.0m in height. All retaining
walls that are publicly accessible and exceed 1.0m in height must be fitted with a
commercial grade safety fence.
Waste Disposal
61. Prior to Council issuing a Development Permit for Operational Works, an amended Waste
Management Plan must be submitted to council for approval that allows for all waste
collection and servicing to occur on site. The amended Waste Management Plan must be
prepared by a suitably qualified person who is experienced in waste management and
includes in particular:
a. Onsite collection of refuse/recycling should be done using 1100ltr low noise waste
containers. Services to be done several times weekly to reduce the actual bin
numbers on site;
b. provision for on-site servicing by a Refuse Collection Vehicle (Dennis Eagle Elite 2
6x4 with rear lift configuration) - the Refuse Collection Vehicle must be able to enter
the site from Thomas Street, service the site, and exit on Albert Street;
c. compliance with The Noosa Plan 2020 – Waste Management Code and PSP9 Waste
Management; and
d. the Refuse Collection Vehicle (Dennis Eagle Elite 2 6x4 with rear lift configuration)
must enter via Thomas Street and exit via Albert Street.
62. The facilities must include an impervious area, within the site, correctly sized for all refuse
and recycling containers and suitably screened from public places and neighbouring
properties. A bin wash area is required with a cold-water tap, hose and drain outlet
connected to sewer, via a bucket trap. The drain outlet must be designed to prevent storm
water entry to the sewerage system. Waste storage and collection areas are to be provided
generally in accordance with the Approved Plans (as amended). The works must be
undertaken in accordance with an Operational Works approval.
63. Refuse containers must be provided in accordance with the requirements of Noosa Shire
Council Local Law No. 7 (Waste Management) 2015 for the storage and collection of
refuse.
64. Storage, disposal and management of solid, liquid and vegetative waste is conducted in a
safe and ecologically sustainable manner without environmental nuisance. In this regard,
vegetated waste must be disposed of via a green waste bin or at a local transfer station.
Services
65. Unless otherwise stipulated by telecommunications legislation at the time of construction,
the development must be provided with all necessary conduits, pits and pipes to
accommodate the future connection of optic fibre technology telecommunications.
Page 10 of 12 10
Section 13
66. Certification must be submitted to Council from all relevant service providers (Energex,
NBN and Unitywater) which certifies that the development has met the requirements of this
Decision Notice and all applicable legislation at the time of construction.
Damage to Services and Assets
67. Any damage caused to existing services and assets as a result of the development works
must be repaired at no cost to the asset owner at the following times:
a. where the damage would cause a hazard to pedestrian or vehicle safety,
immediately; or
b. where otherwise, upon completion of the works associated with the development.
Any repair work which proposes to alter the alignment or level of existing services and
assets must first be referred to the relevant service authority for approval.
Acid Sulfate Soils
68. A preliminary site-specific Dewatering and Acid Sulfate Soils Management Plan must be
prepared and submitted as part of a future Operational Works application for the site. The
Dewater and Acid Sulfate Soils Management Plan must be prepared by a suitably qualified
person and include, but not be limited to:
a. testing, monitoring and treatment requirements for the works in accordance with the
National Acid Sulfate Soils Guidance; and
b. demonstrate how groundwater encountered during excavations and ongoing
operations of the basement will be managed.
Demolition Works
69. Unless specifically conditioned otherwise, all works must comply with the relevant
acceptable solutions as contained in the Waste Management Code and Water Quality and
Drainage Code of the Noosa Plan 2020.
70. Demolition must be undertaken in a manner that causes no detrimental effect upon the
amenity of the neighbourhood by reason of the creation of excessive noise, lighting, air-
borne hazards, atmospheric pollutants (including dust or odours) nuisance or any other
emissions in accordance with the nuisance provisions of the Environmental Protection Act
1994.
Treatment of Temporarily Vacant Land
71. Where some or all of the land remains vacant or undeveloped for more than 3 months, or
buildings are demolished and redevelopment is delayed for more than 3 months, the
following works must be carried out:
a. the site must be cleared of all rubble, debris and demolition materials
b. the site must be graded to prevent ponding (to the same level as the adjoining
footpath wherever practicable), turfed and mown at a minimum 3 weekly intervals
c. the site must be landscaped with perimeter planting consisting of advanced
specimens of fast growing tree species
d. the site must be maintained to ensure no nuisance to adjacent premises, roads or
footpaths
e. where fencing is installed to secure boundaries:
i. the fencing must be durable and not capable of being pushed or blown over
ii. the fencing type must not detract from local amenity (barbed wire is not
acceptable)
iii. vandalism must be promptly repaired, and any graffiti removed.
Page 11 of 12 11
Section 14
Health and Safety
72. All building materials containing asbestos, including asbestos cement sheeting or roofing
and lagging, are removed from the building prior to demolition or relocation.
73. Removal of building materials containing asbestos must be undertaken by a licensed
asbestos removalist.
74. Asbestos removal work (Section 466) of the Work Health and Safety Regulation 2011
requires a licensed asbestos removalist to give notice to Workplace Health and Safety
Queensland (WHSQ) of licensed asbestos removal work at least five days before the work
commences. Notification must be made using Form 65: Notification of licensed asbestos
removal work, demolition work or emergency demolition.
All building materials containing asbestos products are wrapped and disposed of in
accordance with the Public Health Regulation 2006 and the Environmental Protection
Regulation 2008. Note: Asbestos is a Regulated Waste. The Department of Environment &
Science licenses businesses that transport asbestos waste, and landfills that accept this
waste.
Page 12 of 12 12
Section 15
E
D
C 10
ry 11
B da
un 12
boundary
bo
13
01
1
4. 0
14
15 04
4
4.0
3.01 16
01 ing
17 ers
18 rev ne
zo 01
A 19
m
20 2.5 s
o te: idth a
21 n y w re 9 02
a
22 ba this 8
to
23 7
te
24 ga 6 03
25 5
T
3.03
26
03
4
T
3 04
MC
lift
MC
2
MC 1
es
bik
27 es
03 bik s/
ce 04
2 & nal) rvi s tbc
MC s 0 ptio e
s re
02 28 lift 3 o sto
4.02 (lift 0
stair up
43 p
ir u
29 sta tbc
RL 0.0 (TBC) er es 05
42 utt rvi
c
minimum sh se
30 clearance
41 s
height 2.3m ce
p rvi
31 pu se
ram tbc
note: 2.6m (if req'd.
08 EOT
32 bay widths lift 01 by
to this area certifier)
MC
07 33
43 bays 40
bikes
34 total
+possible 39
03 2 tandem
4.03 35
bays
boundary
38
07 7 MC bays
36
15 bikes 04
stair up
--
3.02
MC
02
37
ry
1790m2 reversing da
MC un
internal zone bo
bikes area
06
05
3.04
boundary indicative piling wall, to future
engineer's details
0 4 8 12 20
Basement Plan Scale 1 : 400 @ A3
23 hill street, pomona, qld, 4568 project issue date details n concept design project no.
ph 0410464448 A 12.12.24 planning application drawing
email [email protected]
Mixed Use Developement 2404
B 28.01.25 revised isle & bay widths
abn 56 680 451 058 203 & 207 Gympie Tce Noosaville
C 20.02.25 commercial lift added
basement plan
Reg. No. 5601 (QLD) drawing no.
client scale
© all work subject to copyright and may not be
reproduced without written permission Gympie Tce Pty Ltd NOT FOR CONSTRUCTION 1 : 400 @ A3 CD 2.01 C
13
Section 16
1
yx
ba
ar
gc
stin ree
exi et
tur
fea
e
63
1.
x3 at
°
ys es
ba tre
t c
ar e
e tc tur
tre fea L
ns NG
note:
wo 7 ex. power poles
ne 1.
6
E °
subject to future
pool undergrounding
D
i e
remove ex.
paperbark trees
new car bays x5
p x3
s t
e
ba
ys cap feature
ds ents
+ 2x MC
67
ar lan tree at
1.
m gc er elem
°
n b NGL
sti tim nopy
exi
C ca
y B da
ry
°
1.
70
gs
nin rgo
la bio-retention
68
zone 30m2
g
1.
un aw pe
°
le ber
boundary
bo t a b
im UNIT G 01
01
new footpath
rac n t
1
4 .0
x8 e ret twee 228m2 GFA subject to
ys
ba ob be
C ree t d and RL 2.700 council input
w M t te 04
ne ex. tec d 4.0
4
pro aine
64
3.01
m2
2.
ret
°
01 0 feature
D8
a l b e r t
cap
e O/ tree at
64
ds ent NGL
2.
lan
°
bays x3
new car
er elem 01
A b
tim nopy gs la
ca nin rgo
aw pe
ble mber
70
28
2.
a
2.
t
°
ex. tree to be GL i
e rac n t
°
tur t N ret twee 02
protected and fea es a 0 :14
retained tre p1 be
ram
9
°
1. timber landscape
92
canopy element
1.
°
TENANCY T1 1.
68
03
2 °
5m 245m2 GFA
D7
90
al stair
1.
O/ RL 2.700 nti
°
3.03
ide
03
stair res try platform
73
1.
en
°
lift lift
gate g ate
70
2.
°
fire stair
OL
existing car bays
BOH 91m2
PO
services enclosure
TENANCY T2
97
ED FA
70
1.
R
2.
°
265m2 GFA A G
°
SH m2
FH
RL 2.700 0 04
19 2.70
s
ir lift wa
y R L
x3
02 ta ze
4.02 fires b ree
85
air ir
1.
landscape
sta
°
en
s t
canopy op fire
BOH 97m2
fire stair
elements gate
O/D te 1.
90
05
ga
°
35m2 4
°
1.
73
1:1 No Entry sign
p
am
nr
tria new additional landscaping
es
S
42
d crossover
1.
IN
pe bicycle racks
°
feature tree
sB
lift 4
at NGL 1:1
Re
1:5
08 g
stair din 0 No Entry sign
1:2
gate
70
2.
loa tform rrie
r
p>
°
ba when
72
open air breezeway pla Install sign
1.
od ram
°
flo 2.7 ed)
new car bay x1
07 possible new
(RL ploy
t h o m a s
landscape transformer LARGE VEHICLES
EV de EV
canopy
1:8 1.
52 BE AWARE OF
TENANCY T3 PWD °
V
elements 01
fire stair
O/D BOH BUILDING
MR
0
20
75m2 GFA ramp 1:20
2.
feature tree 30m2 30m2 CLEARANCE
°
03 at NGL RL 2.700 WC WC 3.0M
4.03 35m2 11
existing car bay
RL 2.200 10 (clearance to be
MC
07
MC
09 verified after
one way line marking construction)
fire stair
04 08 ry
TENANCY T4 -- da
roof over 1500h 0 07 un
3.02
BOH :4 bo
x1
02
at 2.6m s'bk 114m2 GFA BINS security p1
ramp 1:14
72
30m2 ram 06
1.
°
feature tree RL 2.700 fence
at NGL 05 left only signage affixed to building
04
06 left turn only linemarking
ramp 1:20 03
65
1.
boundary °
shared access
low height wall ~500mm 02 relocated loading, MC and EV bays
easement two 05
way traffic one way line marking
3.04
2 x No Entry signs
boundary
NOTE 01: Notes & signage requested by TTPLUS
remove MC bays
shown in red
and modify
driveway
two way
Ground Floor Plan NOTE 02: Advice note provided by TTPlus - Specific
Design to be fine tuned at the detailed design stage
linemarking
Traffic Engineer mark-ups as requested - Design intent 4.8m long bays (typical) with 0.6m
font overhang to thin boundary fence - If required,
0 4 8 12 20
some carparks can be shortened and designated as
small car bays; E.g. #05,06&07. Scale 1 : 400 @ A3
23 hill street, pomona, qld, 4568 project issue date details n concept design project no.
ph 0410464448 A 12.12.24 planning application drawing
email [email protected]
Mixed Use Developement 2404
X 23.03.26 for SPA discussion only
abn 56 680 451 058 203 & 207 Gympie Tce Noosaville
XR2 10.04.26 signage & clarifications added
ground floor plan
Reg. No. 5601 (QLD) drawing no.
client (refer to yellow boxes) scale
© all work subject to copyright and may not be
reproduced without written permission Gympie Tce Pty Ltd NOT FOR CONSTRUCTION 1 : 400 @ A3 CD2.02 XR2
14
Section 17
e
t c E
ack
5m
i e
D etb
ss
ed
r b d)
l a nte vere
p ti l e
n
(ca
p e
s t
cap
m
ds ents 43m2
lan
b er elem
y
tim nopy
C ca UNIT 1-02
214 m2 GFA
g
B ry RL 6.300
da
un
bo
boundary
01
1
4.0
30m2 04
4
void 4.0
gs la 3.01
nin rgo
aw pe 01
b le ber
a l b e r t
e ta im
cap rac n t 35m2
lan
ds ent ret twee
er elem be 01
A b
tim nopy
ca
pool
02
30m2 25m2
void
03
16m2
3.03
03
stair
id
vo
UNIT 1-04B UNIT 1-03A 15m2 id
pool vo timber landscape
131m2 GFA 91m2 GFA canopy element
corner awnings 100m2 RL 6.300
between timber 25m2 RL 6.300
pergola
lift m2
UNIT 1-03B 13m2 28 04
lift
sun shade blades
119m2 GFA
ir
02 RL 6.300 sta r
4.02 fire ido
landscape orr A
canopy yc -01 A
elements UNIT 1-04A 15m2 id ze
wa IT 1 GF
vo UN m2 05
104m2 GFA ree 5
13 6.30
0
a ir b
RL 6.300 RL
en m2
op B 13
-01
pool I T 1 FA
id UN m2 G 0
vo
s t
lift 54 6.30
m2 RL
08 13
07 2
landscape 7m
stair
canopy
elements 18m2
below
03 UNIT 1-05
4.03 100m2 GFA
roof below
RL 6.300
07
t h o m a s
UNIT 1-06
100m2 GFA 04
RL 6.300 --
3.02
02
ry
boundary
18m2
da
un
18m2 bo
06
roof below
05
3.04
boundary
Level 01 Plan
0 4 8 12 20
Scale 1 : 400 @ A3
23 hill street, pomona, qld, 4568 project issue date details n concept design project no.
ph 0410464448
Mixed Use Developement A 12.12.24 planning application drawing 2404
email [email protected]
abn 56 680 451 058 203 & 207 Gympie Tce Noosaville B
C
20.02.25
26.02.25
increased setback to thomas st
revised application
Level 01 Plan
Reg. No. 5601 (QLD) drawing no.
client scale
© all work subject to copyright and may not be
reproduced without written permission Gympie Tce Pty Ltd NOT FOR CONSTRUCTION 1 : 400 @ A3 CD 2.03 C
15
Section 18
e
t c E
i e
D
p elo
w
s t
m
fb
roo
en
y
C gre
68m2
g
B ary
und
bo
boundary
01
1
4.0
w 04
elo 4
fb 4.0
3.01 oo
01 e nr UNIT 2-02
gre 49m2 320m2 GFA
a l b e r t
RL 9.600
roof below
A B 20.02.25 increased setback to thomas st
01
02
w
b elo
f
roo 03
en
gre
3.03
03
89m2
lift
UNIT 2-03 36m2
sunshading devices below 294m2 GFA
RL 9.600
green roof below
balcony with sunshading
lift
lift 04
02 ta ir 2
4.02 fir es or 2 0m
id
c orr
way
vo
id ze A 05
ree -01 A
air
b IT 2 GF
en UN 4m2 0
op 11 9.60
RL
id
vo
s t
B
lift -01
08 IT 2 FA
UN m2 G 0
54 9.60
RL
07
UNIT 2-04 A
92m2 GFA
12m2 RL 9.600 8m2
green roof below
03
4.03
07
t h o m a s
8m2
04
--
3.02
02
12m2 UNIT 2-04 B
ary
boundary
92m2 GFA und
bo
RL 9.600
06
05
3.04
boundary
Level 02 Plan
0 4 8 12 20
Scale 1 : 400 @ A3
23 hill street, pomona, qld, 4568 project issue date details n concept design project no.
ph 0410464448
Mixed Use Developement A 12.12.24 planning application drawing 2404
email [email protected]
abn 56 680 451 058 203 & 207 Gympie Tce Noosaville B
C
20.02.25
26.02.25
increased setback to thomas st
revised application
Level 02 Plan
Reg. No. 5601 (QLD) drawing no.
client scale
© all work subject to copyright and may not be
reproduced without written permission Gympie Tce Pty Ltd NOT FOR CONSTRUCTION 1 : 400 @ A3 CD 2.04 C
16
Section 19
e
t c E
i e
D
f
roo
p
en
gre low
b e
s t
m
y
LL
C ry FA
a 3°
nd
g
B b ou elo
w
fb
roo
boundary
n
ree
01
1
g
4.0
04
4
4.0
pergola
3.01 L
01 F AL
5° ROOF
a l b e r t
R
WE 3° FALL (MIN)
LO OF
A w R O 01
elo
B
20.02.25 increased setback to thomas st
fb
oo
e nr
gre ROOF
02
pool
TERRACE 01
160m2 roof below
pergola
LL FFL 03
FA
5° ROOF RL 12.900
R
WE 3° FALL (MIN)
LO OF
3.03
03
R O timber
pergola
ROOF
ROOF
pool
TERRACE 02 void
160m2 3° FALL (MIN)
ROOF roof below
3° FALL (MIN) FFL
04
ALL
02 RL 12.900 5 °F
4.02
timber
pergola void
ROOF parapet 05
3° FALL (MIN)
OF
architectural corner
element below RO
6.0m setback when
LL
closed, 4,5m void FA
5°
s t
setback when open
08
ls
p ane
07 PV
parapet
03
4.03
07 ROOF
t h o m a s
roof below
5° 04
5° FALL --
FALL
3.02
02
ry
boundary
da
un
bo
PV panels
06
05
3.04
boundary
Level 3 Roof Tce Plan
0 4 8 12 20
Scale 1 : 400 @ A3
23 hill street, pomona, qld, 4568 project issue date details n concept design project no.
ph 0410464448
Mixed Use Developement A 12.12.24 planning application drawing 2404
email [email protected]
abn 56 680 451 058 203 & 207 Gympie Tce Noosaville B
C
20.02.25
26.02.25
increased setback to thomas st
revised application
Level 03 Roof Terraces
Reg. No. 5601 (QLD) drawing no.
client scale
© all work subject to copyright and may not be
reproduced without written permission Gympie Tce Pty Ltd NOT FOR CONSTRUCTION 1 : 400 @ A3 CD2.05 C
17
Section 20
e
t c
i e
E
D
p
m
s t
y nd
ary
L
g
C bo
u FAL
5°
R
B WE
LO OF °
RO
boundary
01
1
4.0
04
4
4.0
3.01 L
4
AL
6
2.
F
pergola
below
01
°
5° ROOF
a l b e r t
R
WE
64
2.
3° FALL (MIN)
LO OF
°
A R O 01
B
20.02.25 increased setback to thomas st
2 8
2.
ROOF
°
02
pool
TERRACE 01
ROOF
160m2 roof below
3° FALL (MIN)
°
92
1.
°
LL 03
pergola
below
FA
5° ROOF
R
WE 3° FALL (MIN)
LO OF
3.03
03
R O timber
pergola
ROOF
ROOF
pool
TERRACE 02
160m2 3° FALL (MIN)
7
.9
1
ROOF RIDGE roof below
3° FALL (MIN) 04
RL 15.600 GE 00
02 RID 14.2
4.02 RL
5
8
1
.
timber
pergola
05
90
ROOF
1.
°
3° FALL (MIN)
3
.7
OF
RO
LL
FA
RIDGE 5°
s t
RL 15.600
08 ls
ne
architectural corner pa
PV
72
.
element below
07 6.0m setback when
closed, 4.5m 6 RIDGE
2
setback when open °
.
RL 14.200
0
20
2.
°
03
4.03
07 ROOF
28
roof below
t h o m a s
2.
°
04
5° FALL --
3.02
02
ry
boundary
2
da
un
bo
PV panels
82
06
1.
°
6
boundary
05
3.04
boundary
Roof Plan
0 4 8 12 20
Scale 1 : 400 @ A3
23 hill street, pomona, qld, 4568 project issue date details n concept design project no.
ph 0410464448
Mixed Use Developement A 12.12.24 planning application drawing 2404
email [email protected]
abn 56 680 451 058 203 & 207 Gympie Tce Noosaville B 20.02.25 increased setback to thomas st
Roof Plan
Reg. No. 5601 (QLD) C 26.02.25 revised application drawing no.
client scale
© all work subject to copyright and may not be
reproduced without written permission Gympie Tce Pty Ltd NOT FOR CONSTRUCTION 1 : 400 @ A3 CD2.06 C
18
Section 21
concrete setback 'notch' in concrete setback 'notch' in operable architectural
planter beds building form to planter beds building form to screening elements to
to balcony open metal break up built form pergola structure to balcony break up built form pergola structure sun shading create a dynamic
edge baustrades into 3 elements on roof terrace edge into 3 elements on roof terrace devices corner expression
boundary
boundary
RL 15.600
Roof Tce Ridge
roof terrace for roof terrace for
pool U202 pool U203
RL 12.900
Roof Tce FFL
202 203
RL 9.600
Second Floor FFL
'tide actuated'
U104 timber landscape
102 103 104
pool pool balcony structures
RL 6.300
First Floor FFL
thomas st
G01 T1 T2
RL 2.700
Ground Floor FFL
RL 0.000
Basment FFL
batten stone board finish feature tree at stone stair feature tree ramp up feature tree corner existing
fencing for planter concrete NGL within 'arc' planter at NGL at NGL stair verge
privacy to beds retaining landscpe element beds planting
unit G01 walls
feature tree to feature tree at 'tide actuated' timber pergola 'tide actuated'
corner NGL within 'arc' timber landscape with retractable timber landscape
landscpe element structures awning roofs structures
Elevation 01 - Gympie Tce / North
0 2 4 6 10
Scale 1 : 200 @ A3
23 hill street, pomona, qld, 4568 project issue date details n concept design project no.
ph 0410464448
Mixed Use Developement A 12.12.24 planning application drawing 2404
email [email protected]
abn 56 680 451 058 203 & 207 Gympie Tce Noosaville B 26.02.25 revised application
elevation 01
Reg. No. 5601 (QLD) drawing no.
client scale
© all work subject to copyright and may not be
reproduced without written permission Gympie Tce Pty Ltd NOT FOR CONSTRUCTION 1 : 200 @ A3 CD 3.01 B
19
Section 22
refer to elevation 01
operable architectural
screening elements to setback 'notch' in metal roof at
sun shading open metal sun shading sun shading pergola structure create a dynamic sun shading building form to 5° pitch with sun shading
devices baustrades devices devices on roof terrace corner expression devices break up built form PV panels devices
boundary
boundary
roof terrace for roof terrace for
U202 U203
202 203 204 205
102 103 104 105 106
access
G01 T1 T2 T3 T4 easement
batten stone corner existing verge feature tree feature tree feature tree
fencing for planter beds stair planting at NGL at NGL at NGL
privacy to omitted for
unit G01 clrity
feature tree to 'tide actuated' timber pergola pedestrian timber pergola 'tide actuated' 'tide actuated' stone pedestrian
corner timber landscape with retractable ramp up with retractable timber landscape timber landscape planter beds ramp up
structures awning roofs awning roofs structures structures
Elevation 02 - Thomas St / West
0 2 4 6 10
Scale 1 : 200 @ A3
23 hill street, pomona, qld, 4568 project issue date details n concept design project no.
ph 0410464448
Mixed Use Developement A 12.12.24 planning application drawing 2404
email [email protected]
abn 56 680 451 058 203 & 207 Gympie Tce Noosaville B 26.02.25 revised application
elevation 02
Reg. No. 5601 (QLD) drawing no.
client scale
© all work subject to copyright and may not be
reproduced without written permission Gympie Tce Pty Ltd NOT FOR CONSTRUCTION 1 : 200 @ A3 CD 3.02 B
20