Original source · versioned page text
Earthworks proposal plan
Attached to the e-mail Operational Works Application OPW21/0213 - 21 Nannygai Street Noosaville (Lot 54 on RP76937).
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn NOTES:
1) All fill works on site shall be rolled fill, in accordance with clause 6.4.2 of Australian Standard 2870, and certified by others. LEGEND
2) Survey information has been obtained from 'M3 Surveys' Plan as shown in CDS Design Consultants documentation Ref 'Nannygai' Drawing No.1 Rev C. - INDICATIVE OF PROPOSED FILL - EXISTING TIMBER
All levels, locations and existing services to be verified on site. - (BULK FILL PAD) RETAINING WALL
3) Plans to be read in conjunction with Architectural documentation. - OUTLINE OF FUTURE DWELLING - PROPOSED TIMBER
4) All levels to AHD. RETAINING WALL
- OUTLINE OF PATHWAYS - PROPOSED RETAINING WALL/FENCE
- CORE-FILLED MASONRY BLOCK
5.00 5.00
NEW PATHWAY TO
- 21 NANNYGAI STREET -
4.50 TOP OF RETAINING RL2.55 TAPER FILL PAD TO MATCH EXISTING 4.50
NOM. TOP OF WALL RL4.35 BULK FILL PAD - ASSUMED RL.2.40 GARAGE FILL PAD - ASSUMED RL.2.22 EXISTING SURFACE LEVEL ALIGNMENT
4.00 4.00
1500 MIN.
3.50 PROPOSED IN-GROUND POOL 3.50
(NOT PART OF THIS APPLICATION) FUTURE DWELLING
3.00 3.00
2.50 2.50
2.00 2.00
1.50 1.50
DESIGN SURFACE LEVEL EXISTING SURFACE
1.00 1.00
LEVEL 1.75
0.50 0.50
0.00 0.00
SITE CROSS SECTION 'X1' SCALE 1:100
1.8m TIMBER FENCE 1.8m TIMBER FENCE
5.00 5.00
4.50 TOP OF RETAINING TOP OF RETAINING 4.50
WALL RL2.55 BULK FILL PAD - ASSUMED RL.2.40 WALL NOM. RL2.55
4.00 4.00
3.50 3.50
3.00
FUTURE DWELLING FUTURE DWELLING 3.00
2.50 2.50
2.00 2.00
1.50 1.50
EXISTING SURFACE DESIGN SURFACE LEVEL
1.00 1.00
LEVEL 1.75
0.50 0.50
0.00 0.00
SITE CROSS SECTION 'X2' SCALE 1:100
JESS B GABRILAITIS
RPEQ 23224
COPYRIGHT - The plans, CLIENT PROJECT TITLE
designs and information
contained in this document
ONE PROPERTY PROPOSED
SITE CROSS SECTIONS
are the copyright of
Northside Engineering Pty
Ltd. Use or copying of the DEVELOPMENT BULK EARTHWORKS LOCATION
document in whole or in 19/07/21 ISSUE FOR APPROVAL A UNIT 7, LEVEL 1 21 NANNYGAI STREET, NOOSAVILLE 4566
part without the written 87 WEBSTER ROAD
permission of Northside 12/07/21 PRELIMINARY ISSUE FOR COMMENT STAFFORD QLD 4053 DESIGN DRAWN CHECKED SCALE SHEET JOB NUMBER SHEET OF ISSUE
04235-BE
P1
Engineering constitutes an
infringement of copyright. DATE DESCRIPTION ISSUE
PH. 07 3053 3183
E. [email protected] DR/TZ DR TZ 1:100 u.n.o 1.0m 0 1.0m 2.0m 3.0m
A3 4 5 A