Original source · versioned page text
Attachment 1B - UNITS 1-3 DAVID LOW WAY
Attached to the e-mail RESPONSE to Information Request.
PEREGIAN BEACH VILLAS UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, Sheet Index Layout ID Layout Name Published Sheet Index A.01.1 COVER PAGE A.01.2 GROUND FLOOR A.01.3 FIRST FLOOR A.01.4 ELEVATIONS A.01.5 ELEVATIONS NOTES FOR CONSTRUCTION OF CONCRETE SLAB, FLOOR SYSTEMS, FRAMES & TRUSS'S PLEASE REFER TO HINTON STEEL FRAMES DRAWINGS AREAS GENERAL NOTES GROSS FLOOR AREA CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL UNIT 1: 55 m2 SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA. AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS. STANDARDS. UNIT 2: 55 m2 STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE UNIT 3: 55 m2 DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND WITH THE B.C.A. REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS SCHEDULES OF FINISHES. ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH DIMENSIONS TAKE PRECEDENCE OVER SCALE. AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND AS3788 & PART 3.72 OF THE BCA AS2208 AND THE DESIGN CONDITIONS AS NOMINATED. DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING Collins Developments DIRECTLY TO THE SUPERINTENDENT. BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING HINTON STEEL FRAMES AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm 16 Computer Road Yatala REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, THE ENTRY OF MOISTURE INTO THE BUILDING. AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL Gold Coast SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REQUIREMENTS qld australia 4207 WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION telephone REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. 3.8.1 OF THE B.C.A AND AS 3740 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET (617) 3287 3398 facsimilie AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER (617) 3382 7656 FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS email: [email protected] FOR MEMBER SIZES w w w .h i n t o n s t e e l f r a m e s .c o m .a u
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 4 pages
Page 2
GENERAL NOTES
PEREGIAN BEACH VILLAS UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
4,905 250 4,870 250 4,905
WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
200
1,300 200
1,300 200
1,300 210
200
Patio Patio Patio AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
1.0 x 4.9 1.0 x 4.9 1.0 x 4.9 THE ENTRY OF MOISTURE INTO THE BUILDING.
1,390
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
3.8.1 OF THE B.C.A AND AS 3740
90
90
90
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
STANDARDS.
2,480
2,480
Ens Bed Bed Ens Bed Ens
2.5 x 1.5 3.4 x 3.2 3.4 x 3.2 2.5 x 1.5 3.4 x 3.2 2.5 x 1.5 REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
3,940
3,940
WC WC WC SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
AS3788 & PART 3.72 OF THE BCA
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
90
90
Bi-fold doors by
cabinet maker
16 W UNIT 1 UNIT 2 W 16 UNIT 3 W 16
15 15 15 MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
14
T 14 14 AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
Laundry underneath T
T
13 ROBE ROBE 13 ROBE 13 REQUIREMENTS
staircase 12 12 12
90
90
SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
12,020
11 11 11
11,510
10 10 10 AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
4,400
9 9 9
8 8 8
FOR MEMBER SIZES
7
6
7
6
7
6
LEGEND
5 5 5 A/C AIR CONDITIONING AS SPEC. - INSTALLED
4 4 4 BY CONTRACTOR
AP 450 X450 REMOVABLE ACCESS
7,740
3 3 3
2 2 2
PANEL - LOCATION TO BE CONFIRMED ON SITE
Single Garage Single Garage Single Garage BL CONC. BLOCK WALL TO STRUCTURAL ENG.
6,000
6,000
1 1 1
6.0 x 3.0 6.0 x 3.0 6.0 x 3.0 DETAIL - RENDER AND PAINT AS SPEC.
CF COLORBOND FLASHING TO DETAIL
1,210
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
CONC CONCRETE SLAB TO ENG. DETAIL
CPD CUPBOARD
DP 90mm DIA DOWNPIPE AS SPEC.
90
REFER TO DETAILS FOR TYPICAL FIXING
DRY CLOTHES DRYER
Timber DW DISHWASHER
fence
1,850
EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
GUTTER BRACKETS @ MAX 900 CRS
EGL EXISTING GROUNDLINE
90
90
F REFRIGERATOR
90
FW FLOOR WASTE
GD S.S GRATED DRAIN AS SPEC.
310
310
310
30
310
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
HP HOT PLATES AS SPEC.
Enclosed stairwell HWU HOT WATER
MR MECHANICAL RISER
MW MICROWAVE
1,815 90 3,000 250 3,000 90 1,780 250 3,000 90 1,725 90 NGL NATURAL GROUND LINE
OV OVEN
P PANTRY
1,515 90 3,300 250 3,300 90 1,480 250 3,300 90 1,515 PGL PROPOSED GROUNDLINE
PTF POLISHED TIMBER FLOOR AS SPEC.
RHS RHS TO STRUCTURAL. ENG. DETAIL
RV "WIRILY BIRD" OR SIM. APPROVED
S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 20-03-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Site Plan revised + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16.01.14 Amend GFA CT Date:
UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 20.01.14 Client request amendments CT
PH: 0410 650 745
GROUND FLOOR
BSB No.: 1043429
F 24.01.14 Client request amendments CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
G 04.03.14 Client request amendments
H 20.03.14 Amend design & areas
CT
CT
ECO REMOTE A.01.2 H
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 3
GENERAL NOTES
PEREGIAN BEACH VILLAS UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
410 4,905 250 4,870 250 4,905 410
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
90 1,300 90 3,835 250 3,880 90 900 250 3,835 90 1,300 90
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
THE ENTRY OF MOISTURE INTO THE BUILDING.
Outdoor balcony Outdoor Balcony Outdoor Balcony WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
2,090
2,090
4.8 x 2.1 4.8 x 2.1 4.8 x 2.1 3.8.1 OF THE B.C.A AND AS 3740
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
90
90
STANDARDS.
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
Bay Window
Bay Window
SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
Living Living Living AS3788 & PART 3.72 OF THE BCA
4.8 x 2.4 4.8 x 2.4 4.8 x 2.4
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
16 16 16
15 15 15 MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
5,080
5,080
14 14 14
13 13 13
REQUIREMENTS
12 12 12
SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
11 11 11
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
11,520
11,520
10 10 10
Kitchen Kitchen Kitchen FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
External staircase 9
2.8 x 3.0 2.8 x 3.0
9
2.8 x 3.0
9
FOR MEMBER SIZES
8 8 8
7
6
7
6
7
6
LEGEND
5 5 5
A/C AIR CONDITIONING AS SPEC. - INSTALLED
BY CONTRACTOR
4 4 4
AP 450 X450 REMOVABLE ACCESS
90
90
3 3 3
PANEL - LOCATION TO BE CONFIRMED ON SITE
2 2 2
BL CONC. BLOCK WALL TO STRUCTURAL ENG.
1 1 1
DETAIL - RENDER AND PAINT AS SPEC.
CF COLORBOND FLASHING TO DETAIL
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
CONC CONCRETE SLAB TO ENG. DETAIL
3,000
3,000
2.9 x 3 3.7 x 3 2.9 x 3 CPD CUPBOARD
DP 90mm DIA DOWNPIPE AS SPEC.
REFER TO DETAILS FOR TYPICAL FIXING
DRY CLOTHES DRYER
WC
WC
WC
DW DISHWASHER
EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
GUTTER BRACKETS @ MAX 900 CRS
90
90
EGL EXISTING GROUNDLINE
Balcony Balcony Balcony F REFRIGERATOR
FW FLOOR WASTE
GD S.S GRATED DRAIN AS SPEC.
1,080
1,080
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
HP HOT PLATES AS SPEC.
HWU HOT WATER
MR MECHANICAL RISER
90 1,300 90 1,455 2,380 250 3,970 900 250 2,380 1,455 90 1,300 90 MW MICROWAVE
NGL NATURAL GROUND LINE
250 OV OVEN
480 910 90 2,845 90 900 1,000 90 3,780 250 900 90 2,845 90 910 480 P PANTRY
PGL PROPOSED GROUNDLINE
PTF POLISHED TIMBER FLOOR AS SPEC.
5,315 250 4,870 250 5,315
RHS RHS TO STRUCTURAL. ENG. DETAIL
RV "WIRILY BIRD" OR SIM. APPROVED
S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 20-03-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Site Plan revised + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16.01.14 Amend GFA CT Date:
UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 20.01.14 Client request amendments CT
PH: 0410 650 745
FIRST FLOOR
BSB No.: 1043429
F 24.01.14 Client request amendments CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
G 04.03.14 Client request amendments
H 20.03.14 Amend design & areas
CT
CT
ECO REMOTE A.01.3 H
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 4
ELEVATION LEGEND
PEREGIAN BEACH VILLAS UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0
WD-0
DOOR NUMBER
WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
ALY ALYSNITE FLAT SHEETING
BLK BLOCKWORK
CN CONCRETE
Roof sheets @ 140 pitch fixed in
DP1 90Ø DOWNPIPE
accordance with manufactures FL EG1 EAVES GUTTER
specification FC FIBRE CEMENT WITH 10mm EXPRESSED
JOINTS
FCC COMPRESSED FIBRE CEMENT
MRS
FL FLASHING
FL
Bay window, with specified cladding fixed LVF FIXED ALUMINIUM LOUVRE
MRS
in accordance with manufactures MRS METAL ROOF SHEETING
specification ZINC ZINC CLADDING WITH STANDING SEAM
Ceiling Level EG1 EG1 Ceiling Level
NGL NATURAL GROUND LINE
FL
PLY PLYWOOD WITH 10mm EXPRESSED
JOINTS
SPR SPREADER
Ballustrade, in accordance with the BCA Aluminium framed windows SPT SPITTER
2,740
2,740
and relevant Aus Standards fixed to manufactures
specifications
Timber screen, in front of
Floor Level glass ballustrade Floor Level
Ceiling Level Ceiling Level
Steel post in accordance with engineers
specifications
Aluminium screen, in
2,740
2,740
accordance with manufacteres
Specified cladding fixed in accordance with specifications
manufactures specification
Slab Level NGL NGL Slab Level
1 Left Elevation 1:100
Roof sheets @ 140 pitch fixed
MRS MRS
in accordance with
manufactures specification
Ceiling Level Ceiling Level
EG1 EG1
Ballustrade, in accordance Aluminium framed bifold windows beyond
fixed to manufactures specifications
2,740
2,740
with the BCA and relevant Aus
Standards Bay window with specified horizontal
cladding fixed in accordance with
manufactures specification
Floor Level Floor Level
Ceiling Level Ceiling Level
Specified vertical cladding fixed in
accordance with manufactures
Fire rated wall in accordance specification
with manufacturers
2,740
2,740
specifications Steel post in accordance with engineers
specifications
Slab Level NGL NGL Slab Level
2 Rear Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 20-03-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Site Plan revised + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16.01.14 Amend GFA CT Date:
UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 20.01.14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
F 24.01.14 Client request amendments CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
G 04.03.14 Client request amendments
H 20.03.14 Amend design & areas
CT
CT
ECO REMOTE A.01.4 H
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 5
ELEVATION LEGEND
PEREGIAN BEACH VILLAS UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0
WD-0
DOOR NUMBER
WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
Roof sheets @ 140 pitch fixed in ALY ALYSNITE FLAT SHEETING
FL BLK BLOCKWORK
accordance with manufactures
CN CONCRETE
FL
specification DP1 90Ø DOWNPIPE
Roof sheets @ 70 pitch fixed EG1 EAVES GUTTER
MRS FC FIBRE CEMENT WITH 10mm EXPRESSED
in accordance with
JOINTS
manufactures specification Bay window, with specified cladding fixed FCC COMPRESSED FIBRE CEMENT
MRS
in accordance with manufactures FL FLASHING
EG1
Ceiling Level EG1 specification Ceiling Level LVF FIXED ALUMINIUM LOUVRE
FL MRS METAL ROOF SHEETING
FL ZINC ZINC CLADDING WITH STANDING SEAM
Aluminium framed windows NGL NATURAL GROUND LINE
fixed to manufactures PLY PLYWOOD WITH 10mm EXPRESSED
specifications Ballustrade, in accordance with the BCA
2,740
2,740
JOINTS
and relevant Aus Standards SPR SPREADER
SPT SPITTER
Timber screen to front of
ballustrade
Floor Level Floor Level
Ceiling Level Ceiling Level
Timber post in accordance with engineers
specifications
Aluminium screen, in
2,740
2,740
accordance with manufacteres
specifications Specified cladding fixed in accordance with
manufactures specification
Slab Level NGL NGL Slab Level
3 Right 1 Elevation 1:100
Fire rated wall in accordance
with manufacturers Specified vertical cladding
specifications
Aluminium framed windows
fixed to manufactures
Roof sheets @ 70 pitch fixed specifications
in accordance with
manufactures specification MRS MRS MRS
Ceiling Level EG1 EG1 Ceiling Level
Exposed rafters to roof system
Glass ballustrade, in
Specified vertical cladding
2,740
2,740
accordance with BCA and Aus
standards
Timber screen, in front of Timber screen, in front of
Floor Level glass ballustrade glass ballustrade Floor Level
Ceiling Level Ceiling Level
Specified horizontal cladding
Aluminium screen, in
accordance with manufacteres
2,740
2,740
specifications
21 - 24 roller door
Slab Level NGL NGL Slab Level
4 Front Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 20-03-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Site Plan revised + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16.01.14 Amend GFA CT Date:
UNITS 1-3, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 20.01.14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
F 24.01.14 Client request amendments CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
G 04.03.14 Client request amendments
H 20.03.14 Amend design & areas
CT
CT
ECO REMOTE A.01.5 H
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES