Council archive · source document
Information Request OPW19 0184 · OPW19/0184
Officer: Mark Lewis Direct Telephone: 07 53296290 Our Reference: OPW19/0184 Your Reference: . 30 August 2019 Pile-It Pty Ltd PO Box 672 NOOSAVILLE QLD 4566 [email protected] Dear Sir Information Request Planning Act 2016 I refer to your application and advise that Council requires further information to satisfactorily assess the proposal. application details Application No. OPW19/0184 Street Address: 22 Cooran Ct Noosa Heads Qld 4567 Real Property Description: Lot 227 N 21857 Planning Scheme: The Noosa Plan (8 June 2018) INFORMATION REQUIRED The information requested is set out below: Issue The submitted design certification does not make reference to the Noosa Plan – Watercourses Works Code or the Coastal Protection and Management Regulation 2017 – Code for assessable development that is prescribed tidal works Information Required Provide amended design certification that makes reference to the Noosa Plan – Watercourses Works Code and the relevant sections of the Coastal Protection and Management Regulation 2017 – Code for assessable development that is prescribed tidal works Issue Council has some concerns with the submitted design plans: The plans indicate a “removable seat”. The purpose of the jetty is provide access to a jetty and not for the extension of private open space. The plans indicate a “maximum water level of RL0.44m AHD”. The site is in a tidal area and no indication has been provided how the water level has been determined. The plans do not indicate any lighting on the jetty. It may be necessary to include lighting to achieve compliance with the relevant codes. Information Required Provide amended plans that do not indicate the removable seat Provide comment as to how the “maximum water level of RL0.44m AHD” has been determined and whether the tidal movements impact on this level If required indicate on the plans any proposed lighting. Please note that any electrical reticulation system carrying electricity in excess of 24 volts beyond the revetment wall is not supported unless all switches and power outlets are positioned above the 1%AEP flood level due date for response to information request The due date for providing the requested information is 30 November 2019. Please advise Council of your response to this information request in accordance with section 13 of the Development Assessment Rules. If you do not provide a response before the due date, it will be taken as if you have decided not to respond to the information request and Council will continue with the assessment of your application. other details You can follow the progress of this application online at www.noosa.qld.gov.au. The “Online Services” page can be accessed via "Quick Links" on the left hand side of the screen. Should you have any further queries in relation to the above, please do not hesitate to contact me on the number above. Yours faithfully, Mark Lewis Coordinator - Engineering [word/footer1.xml] Page 2 of 2 [word/footer2.xml] PO Box 141 P. (07) 5329 6500 [email protected] TEWANTIN QLD 4565 F. (07) 5329 6501 www.noosa.qld.gov.au Page 1 of 2 [word/header1.xml] 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original