Attachment C -Proposed Carparking
ALL DRAWINGS TO BE PRINTED IN COLOUR!
EDGE LINE
SSD SSD
SSD SSD
SSD SSD
SSD
SSD
E
SSD
PP
SSD
-
SSD
SSD
SSD
SSD
SSD
SSD
SSD
SSD
SSD
SSD
SSD
1.20
SSD
SSD
SSD
SSD
PROPOSED LANDSCAPING AREA WITH LOW
EL
LEVEL PLANTING. PROVIDE SUB SOIL
DRAINAGE AND CONNECT TO SUBSOIL DRAIN
MAPLE STREET
3.00
BENEATH CONCRETE INVERT IN CARPARK
600mm WIDE CONCRETE TRAFFIC ISLAND
CLL
KERB ONLY TYPE SM3 AS PER
IPWEAQ STD DRG RS-080 WITH 300mm CUTBACK LINE CONTINUITY LINES
SIGNAGE AS PER IN ACCORDANCE
3.00
300mm WIDE CCS BISCUIT existing edge of bitumen PROVIDE GROUTED ROCK SCOUR
WITH IPWEAQ STANDARD
CONCRETE BACKING STRIP PROTECTION WITH 100mm (D50)
DRAWING RS-130 & RS-131. EL
"NO ENTRY" - FACING MAPLE ST 106.5
0
"GIVE WAY" - FACING CARPARK
1.20
106.25 106.25 106.25 CL
106.50
106.50 106.50
106.50
106.25 106.25
CONTINUITY LINES 106.25 106.25
106.25
106.50
0
106.5 CL
106.75
B1 KERB 900mm WIDE 106.25
3.30
900mm WIDE & CHANNEL CONCRETE INVERT 106.25 106.25
JOINS SHEET C11
CONCRETE INVERT 106.25 FSL 106.122 FSL 106.010
5
0
106.5
106.7
FSL 106.580
106.00
106.2
5 10 106.00
JOINS SHEET C09
6.2
5
2. FSL 106.047
60
5
PP
106
.50 FSL 106.277 6.2
10
.50
HL
106
9 8 7 6 5 4 PROVIDE 200mm
FSL 106.390 10 3 2 1 SLOT/CHUTE IN KERB.
10
HOLD LINE 11
5.
33
PP
12
7.
900mm WIDE existing overhead INVERT OF CARPARK
0
CONCRETE INVERT
.60
6.0
power pole TO DISCHARGE TO
10
106
KERB106.5
AND 0 CHANNEL EXISTING CULVERT
106.25 106.25
106.75 106.50
TYPE M1 - AS PER 106.50
106.25
5
6.2
PP
IPWEAQ STD DRG RS-080 106.50 existing watermain (location
10
to be confirmed by potholing)
FILE:N:\PI\Design_Services\CAPITAL WORKS\2017-2018\Hinterland Playground, Cooroy\Drawings\Working\Hinterland Playground.dwg DATE:10/Feb/2020 BY:blhuillier
106.50
existing overhead 106.25 KERB ONLY TYPE B2 - AS106.25
PER
106.50
power pole KERB10ONLY TYPE B2 - AS PER 106.25 IPWEAQ STD DRG RS-080
106.75
106
.75
106.50 IPWEAQ STD DRG RS-080 106
.25
.255
106.2
106
existing telecomms (location
106.50 106.25
to be confirmed by potholing)
CONCRETE PATHWAY LINK TO
CARPARKING AND MARY RIVER
ROAD PEDESTRIAN BRIDGE 106.25
APEX PARK 106.25
0 2 4 6m
Scale 1:100 @A1
CONCRETE TRAFFIC ISLAND
MAPLE ST
APEX PARK 2.50 VARIES 3.30 0.60 1.20 3.00 3.00 1.20
2.50% -5.00%
1 in 6 2.50% -5.00%
EXISTING SURFACE
OVERHEAD ELECTRICITY CABLES
EXIST IN THIS VICINITY. CONTACT CUTBACK INTO EXISTING PAVEMENT AS
ENERGEX WHERE CABLE CONCRETE PATHWAY
PER IPWEAQ STANDARD DRAWING RS-170
CLEARANCE IN COMPROMISED BY
MACHINERY. B2 KERB ONLY ROADWAY PAVEMENT - REFER DETAILS ON SHEET C01
EXISTING
CAUTION: UNDERGROUND
NOTES: AC WATERMAIN - DIAMETER AND TELSTRA 900mm WIDE CONCRETE INVERT
1. REFER ALSO TO DESIGN & EXISTING LEGENDS ON DEPTH TO BE CONFIRMED
SHEET C01.
2. REFER TO SHEET C06 FOR DESIGN SETOUT TABLES. MAPLE ST - CARPARK AREA 1
3. REFER DEMOLITION PLANS ON SHEETS C07 & C08
0 1 2 3m
FOR FURTHER DETAILS. SECTION E
4. REFER TO SHEET C15 FOR CONCRETE JOINT DETAILS SCALE 1:50 Scale 1:50 @A1
DRAFT MAPLE STREET - COOROY
E PSM No 138979 | 158664 Capital Project Number
D NOOSA COUNCIL INFRASTRUCTURE
0000583
A1
(AHD) RL 106.960 | 106.277
C PLANNING, DESIGN & DELIVERY HINTERLAND PLAYGROUND - APEX PARK AND MILL PLACE
B 22/01/2020 DRAFT ISSUE M.T. C.E. SURVEYED A CRAMPTON 08 / 2018
A 15/08/2019 ISSUED FOR REVIEW M.T. C.E. DRAWN B L'HUILLIER 08 / 2018
PO Box 141 Tewantin, TEWANTIN QLD 4565 UPGRADE WORKS Sheet No. - Revision No.
Rv DATE REVISIONS REC. APPR. CHECKED ph:(07) 5329 6500 | email: [email protected] MAPLE ST - CARPARK AREA 1 C10 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Attachment C -Proposed Carparking.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.