CS
exis TING
street
Fenced
‘open use’
arehnouse
eC XiS TING
7
— t
exis TING
street
tree __
street =
tree _.
TING VALVE ABOVE
UND MOUNTED ON POST FOR
IRRIGATION. FOR DETAILS OF
IRRIGATION REFER TO OTHERS.
———#20 IN GROUND
CXIS TING
D
? \
ath
ontinues
EXISTING HYDRANT
TO BE CONFIRMED
\ © HYD
1 —=——MAX 20m
FEED TO
°
coeese aaa bol |
wee sharen Nc WATER
Fe ZONne MAINS
ee 0150uPVC pni6
wet CONTINUE. WITH
20 IN GROUND
N TO HC’s \ . +
a Op AR al
> cot I i
f FHR _
‘ hl / L925 IN GROUND 13 {
: FIRE HOSE REEL REFER TO ETAL’ || tt st—<ti‘“‘“‘z!:SC
; opening _ L “1
/ 2e/xes A |
Jo Foyer
f type 4
} trade related sales Showroom
HWS UNDER
BENCH REFER
TO SPEC. 5
/
J J FOR PLUMBING
4 -~ eiumibing REQUIREMENTS
COORDINATE WITH
staff . - tucker SUPPLIER
room flexi desk] of fice Ire.
~ AT HICH LEVEL
——25 IN GROUND |
925 RPZD
4 #25 TO FHR
AND HC’s#
GATE VALVE,
tore [PEN
I
—
| EXISTING SLUICE VALVE WITH
= i 150 CAPPED PROPERTY
a | CONNECTION AS PER VDM
APPROVED DRAWINGS
Linn
RISE 20 COLD TO HIGH LEVEL:
20 TO 4 bevel
APPLY TO AUTHORITY FOR NEW.
25 DOMESTIC SERVICE
INCLUDING MASTER METER AND
GATE VALVE, LOCKED OPEN AT
DEVELOPERS COST
<;
HOT WATER SYSTEM SPECIFICATION:
HWS FOR STAFF SINK:
TYPE: ELECTRICAL, CONTINUOUS FLOW, SINGLE PHASE UNDER BENCH
MANUFACTURER: STIEBEL ELTRON
MODEL: DHCE 8/60
Edge of FHR Bolted
Wall To Wall
100 min — Extended Guide Arm
i 25 Control Valve
220 Rubber With Nozzle Locking Device
°
3 Hand Control
@25min Services
Backflow Prevention
If Used For Other Then
fire fighting (DCV)
<<. = oe
FIRE HOSE REEL DETAIL
NTS
INSTALLATION IN ACCORDANCE WITH AS1221 AND AS2441
NOTE:
The pressure and flow test has
resulted in an available 300kPA @
20I/s flow. This is sufficient for
external feed hydrants as per
AS2419. The author can not take
liability for future changes in regards
to the pressure and flow data
available in the mains.
DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED
FOR ASSESSMENT, TENDERING AND CONSTRUCTION.
Amd Description Date
B NEW ARCHITECTURAL LAYOUT; RESPONSE TO RFI 15-10-14
A NEW ARCHITECTURAL LAYOUT 11-09-14
Issue Notes Date
For Development Approval X 21-05-14
For Building Approval x 21-05-14
For Tender
For Construction
As Constructed
E Hydraulic 3:
I
I
~ . . >)
contact: Reinhold Koenning MiEAust RPEQ No 7023
PO Box 181
Moffat Beach, QLD, 4551
email: [email protected]
PH: (07) 5491 4333 FX: (07) 5491 4233
CLIENT :
WILSON CLARK CONSTRUCTIONS
ARCHITECT :
LL COOL ARCHITECTURE J
(PRosect: 10/100 RENE STREET Y
NOOSAVILLE
DRAWING TITLE:
\
WATER SUPPLY
AND
HYDRANT COVERAGE
Design AnH. Checked (Ch. Date 21-05-14 Dwg. No. AMD.
\ Scale: 1: 100 ON At UNO. 4 Of 4 2864—-H4 By
RPD:— LOT 10 SP 230643
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Council's Information Request.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.