Minor Change Application
Attached to the e-mail RE_ MCU23_0085 - Mitton - Request for Minor Change to a Development Approval - 7 Ashdown Court_ Tinbeerwah QLD 4563.
Original PDF page 27, section 1. The text section number identifies this passage in the reader.
THIS DRAWING IS SUBJECT TO COPYRIGHT LAWS AND
MAY NOT BE COPIED WITHOUT THE WRITTEN PERMISSION
OF ANNA PAROZ DESIGN AND DRAFTING ©
NOTES :
1. PROVIDE 3 PHASE SUPPLY FROM STREET.
2. PLACE ALL LIGHT SWITCHES AT 1100mm FFL.
3. PLACE ALL POWER POINTS AND OUTLETS TO SUIT CABINETRY
AND/OR FITTINGS. REMAINING POWER POINTS AND OUTLETS
TO BE MOUNTED 300mm FFL.
4. ENERGY EFFICIENT LIGHTING TO BE INSTALLED TO A
MINIMUM OF 80% OF TOTAL FIXED LIGHTING
POSITIONS. (BASED ON NUMBER OF LIGHTS INSTALLED
INTERNALLY & IN OUTDOOR COVERED AREAS).
5. PROVIDE SUPPLY TO A/C UNITS AS REQUIRED.
G:\_UserData (CURRENT)\Documents\1. Desktop from Old Computer (CURRENT)\Desktop (Current)\ANNA'S Comp SD (Current)\2025 Current Design Jobs\Mitton Cameron, Karen Tinbeerwah 2025\Mitton 2 Shed House.rte
6. PROVIDE SEPERATE CIRCUIT FOR FRIDGE.
7. GARDEN LIGHTS TO BE ON MOTION SENSORS.
8. GARDEN LIGHTS TO FUTURE DETAIL.
9. PROVIDE DIMMERS TO ALL PENDANT LIGHTING
NOTE - PROVIDE POWER TO THE FOLLOWING
FITTINGS
REFRIDGERATOR, HOT PLATE, RANGE HOOD,
WALL OVEN DISHWASHER HOT WATER SYSTEM
FRONT GARAGE DOOR(S) AND SMOKE
DETECTORS
ELECTRICAL LEGEND
LIGHTS & FANS
FLUORESCENT TUBE SL SENSOR LIGHT
CEILING LIGHT POINT A MOTION SENSOR
ADJUSTABLE
JB WALL LIGHT PT JUNCT. BOX
DOWNLIGHT
DOWN LIGHT STAIRLIGHT
EXHAUST FAN OR COMPACT FLUORESCENT
HEAT/FAN/LIGHT (H/F/L) DOWNLIGHT
AC OUTLET & AIR
P PENDANT LIGHT
DIRECTION
CEILING FAN (L= LIGHT)
SWITCHES & POINTS
SINGLE GPO LIGHT SWITCH
DOUBLE GPO PERMANENT POWER
EXTERIOR SINGLE GPO SA SMOKE ALARM / DECTOR
TELEVISION POINT
TV
NBN CAT 6 DATA POINT
TEL TELEPHONE POINT H HILLS HOME HUB
SINGLE GPO IF ALARM
GAS
GAS POINT
INSTALLED AS STANDARD
NOTES: PLEASE NOTE: DETAILS SHOWN ON THESE PLANS ARE INTENDED TO BE CLIENT: JOB DRAWN BY: DATE DRAWN: CHECKED BY: APPROVED FOR
ACCURATE - HOWEVER INFORMATION WRITTEN INTO INDIVIDUAL CONTRACTS WILL DESCRIPTION : CONSTRUCTION:
TAKE PRECEDENCE OVER PLANS CAMERON & KAREN MITTON AP 08.04.25
* ALL DIMENSIONS ARE IN MILLIMETRES
CUSTOM DESIGN - BAL FZ
* DO NOT SCALE - USE WRITTEN DIMENSIONS
56 OYSTER BANK ROAD, SITE ADDRESS: NOT FOR CONSTRUCTION COUNCIL AREA: SCALE:
* ALL DIMENSIONS ARE TO STRUCTURAL FRAMES ONLY EXCLUDING
FINISHED (EXISTING) SURFACES BLI BLI, QLD 4560 RP186535 PROGRESSION STAGE : WORKING DRAWINGS 1 NOOSA SHIRE 1 : 100
* READ THESE PLAN IN CONJUCTION WITH STRUCTURAL ENGINEERS PLANS
& RELEVANT CONSULTANTS - REF. TO BUILDER
TELEPHONE : 0412 105 174 7 ASHDOWN COURT, TINBEERWAH ISSUE:
DRAWING TITLE: JOB No: DRWG No:
* ALL CONSTRUCTION WORKS TO BE IN ACC. WITH DA APPROVAL CONDITIONS
EMAIL : [email protected] QLD, 4563
AND COUNCIL APPROVED PLANS. NOTE DISCREPANCES & REF. TO DESIGNER Building Design Licence no. 1269235 (Low Rise) RES. E.L - ELECTRICAL PLAN A0068724 3.5a E.L. Lr