SLAB NOTES: THIS DRAWING IS SUBJECT TO COPYRIGHT LAWS AND
0.2MM POLYETHYLENE VAPOUR BARRIER DIRECTLY UNDER SLAB LAPPED 200MM MINIUM AT JOINTS AND TAPED WITH APPROVED TAPE TO PROVIDE A MAY NOT BE COPIED WITHOUT THE WRITTEN PERMISSION
WATERPROOF SEAL.
50MM MINIMUM THICK SAND BEDDING, COMPACTED AND LEVELED.
WHERE FLOOR WASTES ARE INSTALLED, ADEQUATE FALLS ARE TO BE PROVIDED IN ACCORDANCE WITH THE NCC VOL2, 3.8.1 WET AREAS.
OF ANNA PAROZ DESIGN AND DRAFTING ©
SLAB HEIGHTS
MIMIMUM FINISHED SLAB HEIGHT MUST BE DETERMINED FOR EACH INDIVIDUAL PROJECT AND IS DEPENDENT UPON DESIGN FACTORS SUCH AS -
A) SUFACE WATER DRAINAGE AS PER NCC PART 3.1.2.3
150MM ABOVE ADJACENT FINISHED GROUND LEVEL OR 100MM ABOVE SANDY, WELL-DRAINED AREAS OR 50MM ABOVE PAVED OR CONCRETED AREAS WHICH
FALL AWAY FROM THE DWELLING FOR 50MM OVER THE 1ST 1METRE.
(CHECK STATE VARIATIONS)
B) MASONONARY VENEER CONSTRUCTION WHERE DPC'S MUST BE150MM MINIMUM ABOVE ADJACENT GROUND LEVEL AND REQUIRE A SLAB EDGE RECESS AS
PER BCA PART 3.3.4.5-
170MM ABOVE ADJUACENT FINISHED GROUND LEVEL OR 95MM ABOVE ADJACENT PAVED OR CONCRETED AREAS WHICH FALL AWA FROM THE WALL OR 70MM
ABOVE ADJACENT PAVED OR CONCRETED AREAS.
C) LEVEL RELATIVE TO DRAINAGE ORG AS PER AS.3500, PLUMBING AND DRAINAGE CODE -
150MM MINIMUM ABOVE TOP OF ORG TO LOWEST FIXTURE POINT I.E. FLOOR WASTE OR SHOWER DRAIN.
LEVEL OF ORG MUST BE 75MM MIN. ABOVE FINISHED GROUND LEVEL.
D) STANDARD BUILDING REGULATIONS REQUIRE THE LEVEL OF ALL HABITABLE ROOMS BE 300MM MINIMUM ABOVE THE Q50 FLOOD LEVEL OR AS
DETERMINDED BY THE LOCAL AUTHORITY.
E) LOCAL TOWN PLANNING SCHEMES MAY SPECIFY FLOOR LEVELS RELATIVE TO FINISHED SURFACES IN RURAL AREAS.
TERMITES
A TERMIATE MANAGEMENT SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH NCC PART 3.1.3 & AS3660-TERMITE MANAGEMENT FOR A SLAB CONFORMING
WITH AS2870 - RESIDEDENTIAL SLABS & FOOTINGS -
CONSTRUCTION
G:\_UserData (CURRENT)\Documents\1. Desktop from Old Computer (CURRENT)\Desktop (Current)\ANNA'S Comp SD (Current)\2025 Current Design Jobs\Mitton Cameron, Karen Tinbeerwah 2025\Mitton 2 Shed House.rte
TERMITE BARRIERS MUST BE INSTALLED IN ACCORDANCE WITH MANUFACTUREERS RECOMMDATIONS OR BY AN ACCREDIDITED TECHNICIAN.
WHERE A CONCRETE SLAB-ON-GROUND IS USED AS THE BARRIERS, NOT LESS THAN 75MM OF THE SLAB EDGE MUST BE A CLEAN, SMOOTH FINISH AND MUST
NOT BE CONCEALED BY RENDER, TILES, CLADDING OR FLASHINGS.
8000
270
POST - SACRIFICAL 75SHS
255
(CONFIRM WITH ENG. DETAILS)
GARAGE
8000
4
31
11
11
31
9375
4
WALKWAY
1215
9104
1375
9104 350350 625
175350350
160
160
3925 350350 4375 POST - SACRIFICAL 75SHS
100 8000 900
9000
GARAGE ELECTRICAL PLAN GARAGE SLAB & WALK WAY
1 : 100 1 : 100
CLIENT: JOB DRAWN BY: DATE DRAWN: CHECKED BY: APPROVED FOR
NOTES: DESCRIPTION : CONSTRUCTION:
PLEASE NOTE: DETAILS SHOWN ON THESE PLANS ARE CAMERON & KAREN MITTON AP 08.04.25
INTENDED
CUSTOM DESIGN - BAL FZ
TO BE ACCURATE - HOWEVER INFORMATION WRITTEN INTO 56 OYSTER BANK ROAD, SITE ADDRESS: NOT FOR CONSTRUCTION COUNCIL AREA: SCALE:
INDIVIDUAL CONTRACTS WILL TAKE PRECEDENCE OVER PLANS BLI BLI, QLD 4560 RP186535 NOOSA SHIRE
PROGRESSION STAGE : WORKING DRAWINGS 1 1 : 100
* ALL DIMENSIONS ARE IN MILLIMETRES TELEPHONE : 0412 105 174
* DO NOT SCALE - USE WRITTEN DIMENSIONS 7 ASHDOWN COURT, TINBEERWAH DRAWING TITLE: JOB No: DRWG No: ISSUE:
EMAIL : [email protected]
* ALL DIMENSIONS ARE TO STRUCTURAL FRAMES ONLY QLD, 4563 A0068724 4.4 Lr
EXCLUDING FINISHED (EXISTING) SURFACES Building Design Licence no. 1269235 (Low Rise) GARAGE ELEC. & SLAB