               29.    Pram ramps shall be installed on the Links Drive pathway at the location of the pedestrian
                      refuge that is to be constructed on the leg of the roundabout servicing the proposed
                      development.
               30.    All paths, pram ramps, driveways and parking areas shall be designed and constructed to
                      ensure pedestrian safety using non-slip materials, to produce an evenly graded surface
                      finish, and to be in accordance with the Disability Discrimination Act 1992 and Australian
                      Standard 1428.1 Design for Access & Mobility.
               31.    All redundant vehicular crossings to the site shall be removed and replaced by kerb &
                      channel, footpath paving and landscaping such as trees and grasses in accordance with
                      Council’s Standard specifications prior to commencement of the use permitted by this permit.
               Car Parking
               32.    Carparking shall be provided within the site as shown on Plan M1806-11A dated 7 November
                      2007 as submitted by Jones Flint & Pike except as modified herein for at least 14 spaces.
                      The carparking area shall be designed to comply with the provisions of AS 2890.1-2004 for
                      user class 1. The minimum head clearance (headroom) at any point shall be 2.3m.
               33.    The carparking area shall be drained and the pavement constructed to access road
                      standards. Plans and specifications for these works shall be submitted in conjunction with
                      an application for a Development Permit for Operational Works.
               34.    All carparking shall be kept maintained and line-marked in a condition fit for use, or delineated
                      in another approved manner, to the reasonable satisfaction of Council.
               Power
               35.    An underground electricity service shall be provided to each lot.
                      In this regard, an approved ENERGEX Electrical Design Consultant shall work in conjunction
                      with Council’s Manager - Works Support to prepare detailed designs of the electrical
                      proposal.
                      The detailed designs shall then be submitted to ENERGEX for approval and a copy of their
                      approval submitted to Council in conjunction with a “Certificate of Electricity Supply for
                      Proposed Subdivisions” (prepared by an approved ENERGEX Electrical Design Consultant)
                      prior to Council endorsing the Plan of Survey.
                      Any agreement with ENERGEX or an approved ENERGEX Electrical Design Consultant
                      shall be wholly at the applicant’s expense and shall not entail a financial encumbrance on
                      future purchasers of the proposed lots.
               36.    Street lighting and pathway lighting throughout the subdivision shall have a high energy
                      efficient rating to the reasonable satisfaction of Council and shall generally be provided in
                      accordance with the principles of Council’s Engineering Design Standards.
               Telecommunication
               37.    The requirements for TELECOMMUNICATION services shall be satisfied in relation to the
                      provision of new underground telephone services to the proposed lots. In this regard written
                      confirmation from an approved telecommunication agency shall be submitted to the Council
                      prior to Council endorsing the Plan of Survey.
               Roof Water
               38.    Roof runoff from any new dwelling/building shall be directed to a rainwater storage system
                      or tank that is installed to ensure water from the rainwater storage system or tank is used for
                      external uses (such as watering gardens, irrigation, ornamental ponds, water features,
                      topping-up swimming pools, outdoor cleaning, etc) and for internal (ground floor) use in
                      washing machine cold taps and toilet cisterns. All rainwater tanks are to be designed and
                      installed in accordance with the Queensland Development Code (QDC) current at the time
                      of building approval, and shall be part of the plumbing application for approval. The location
                      and capacity of the tanks shall be clearly shown on the plans submitted for Building Works
                      approval and any overflow shall be directed to the stormwater drainage system.


                                                                                                        Page 6 of 18
Document Set ID: 22620408
Version: 5, Version Date: 19/10/2023

Used in these records

About this file

File size
211 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED - Minor Change Existing Approval 132007 2399 02.pdf · 211 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.