Council archive · source document
Approved Plan MCU17-0565 & OPW17-0599 · MCU17/0565
Plans and drawings: the text below has words only, no drawings.
600
8M HEIGHT LINE @ SECTION
600 B C
OH
OH 5.1 5.2
ROOF INSULATION AS PER NCC REQUIREMENTS
TRIMDEK METAL ROOF SHEETING, COLORBOND PARAPET PARTY WALL, FIRE SEPARATION; BLOCKWORK
FINISH, FIXED TO MANUFACTURERS DETAIL CONSTRUCTION TO ENGINEERS DETAILS. ACCOUSTIC
207.940 D3.02A 2.00° WIR D3.01A
REQUIREMENTS AS PER CSR REDBOOK
207.717 METAL GUTTER, HALF ROUND PROFILE M Design
CL2
PO Box 290
100mm PVC DOWNPIPE, PAINT FINISH Peregian Beach QLD 4573
BSA No. 1066058
FC SOFFIT LINING FIXED TO
MANUFACTURERS DETAIL, PAINT FINISH 9mm FC CLADDING, TIMBER COVER
STRIPS AT JOINTS, RANDOM AT 450 Contact: Michael Broeren
206.223 600 600
2700
GLAZING AS PER SCHEDULE BED 1 CRS AS PER ELEVATIONS, PAINT FINISH t. 07 5471 2721
OH OH t. 0422 969 645
GATE & FENCE TO
DETAIL, PAINT FINISH ROOF INSULATION AS PER NCC REQUIREMENTS w. www.m-designs.com.au
205.000
UNIT 1
2S
205.280
LEVEL 2
TO
300
CL1
RE
Y
KITCHEN MEALS BATH
HALL BED 3
2700
LIVING WALL INSULATION AS PER NCC REQUIREMENTS
© COPYRIGHT 2017 - M DESIGN
RETAINING WALL,
THE IDEAS AND CONCEPTS
EXTENTS TBC PLASTERBOARD LINING, FIX TO
2S 202.000 MANUFACTURERS DETAIL. PAINT FINISH
CONTAINED WITHIN THIS DOCUMENT
AND THE DOCUMENT ITSELF REMAIN
NGL TO
LEVEL 1 RE THE INTELLECTUAL PROPERTY OF M
CUT Y DESIGN AND MAY NOT BE COPIED
300
CL FLOOR BEAMS & JOISTS TO ENGINEERS DETAILS OR REPRODUCED IN PART OR IN
WHOLE WITHOUT EXPRESSED
D1.02A D1.01A WRITTEN PERMISSION FROM
GALV STEEL COL TO MICHAEL BROEREN OF M DESIGN.
ENGINEERS DETAILS
16.10.17
21.12.17
15.02.18
28.02.18
UNIT 2
DATE
2700
CUT & FILL AS PER NCC REQUIREMENTS
NGL CARPORT SCREEN TO DRYING COURTYARD
WATERPROOF MEMBRANE AS PER
SPEC,INSTALLED TO MANUFACTURERS DETAIL CUT
199.000
GF
REVERSING PAD TO ENGINEERS DETAILS
DESCRIPTION
REINFORCED CONCRETE FOOTINGS 150 SAND BEDDING WITH
& SLAB TO ENGINEERS DETAILS. VAPOUR BARRIER TO SLAB BASE CUT & FILL AS PER NCC REQUIREMENTS
COUNCIL APPROVAL
LAUNDRY CUPBOARD & CHUTE
CONSULTANT ISSUE
CONSULTANT ISSUE
SECTION AA
COUNCIL RFI
A
1 : 100 8M HEIGHT LINE @ SECTION 5.1
REV
C
D
B
E
PARAPET PARTY WALL, FIRE SEPARATION;
BLOCKWORK CONSTRUCTION TO ENGINEERS DETAILS. 600 600
ACCOUSTIC REQUIREMENTS AS PER CSR REDBOOK
207.700 OH OH
CL2 207.650
7 Parkedge Road, Sunshine Beach QLD
ROOF INSULATION AS PER NCC REQUIREMENTS
600 600
OH OH METAL GUTTER, HALF ROUND PROFILE
2.00°
2700
205.967 2.00°
205.967
100mm PVC DOWNPIPE, PAINT FINISH
2.00° UNIT 2 UNIT 1
LEVEL 2 PLASTERBOARD LINING, FIX TO
MANUFACTURERS DETAIL. PAINT FINISH
300
CL1
PROPOSED DUPLEX
WALL INSULATION AS PER NCC REQUIREMENTS
LIVING LIVING
STAIR 2
STAIR 2
9mm FC CLADDING, TIMBER COVER
STRIPS AT JOINTS, RANDOM AT 450
CRS AS PER ELEVATIONS, PAINT FINISH
2700
HALL HALL
FEATURE TIMBER CLADDING
JOINERY ITEM
PRELIMINARY - NOT FOR CONSTRUCTION
Project Address:
202.000
LEVEL 1
300
CL FLOOR BEAMS & JOISTS TO ENGINEERS DETAILS
Craven
l
co l
RENDERED BLOCKWORK WALL TO ENGINEERS DETAILS
co l
For:
co
STAIR 1
STAIR 1
UNIT 1
2700
CUT & FILL AS PER NCC REQUIREMENTS sheet title:
CARPORT
WATERPROOF MEMBRANE AS PER
SPEC,INSTALLED TO MANUFACTURERS DETAIL 199.000 -
GF SECTIONS
NOOSA COUNCIL
APPROVED PLAN job no: drawn by:
REINFORCED CONCRETE FOOTINGS
& SLAB TO ENGINEERS DETAILS.
150 SAND BEDDING WITH
VAPOUR BARRIER TO SLAB BASE
MCU17/0565 & OPW17/0599 1723 LBW
17 MAY 2018
date: 3/04/2018
SECTION BB 0 1 2 3 4m
2:32:38 PM
scale (A3): drawing no:
1 : 100 1:100
1 : 100 5.1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plan MCU17-0565 & OPW17-0599.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.