Council archive · source document
Draft Condition Response CT · REC13/0015
Callaghan & Toth Consulting Engineers Pty Ltd ABN No. 45140292324 8/41 Sunshine Beach Road Noosa Junction P.O Box 2305 Noosa Heads 4567 Callaghan & Toth www.callaghanandtoth.com.au Civil. Envi 1 & Hyd lic Engi Ph: 07 5474 9081 Fax: 07 54749041 iil, Environmenta: yeraulic Engineers st 13" June 2013 File No: 1225 Sunshine Coast Regional Council C/- Max Watterson and Associates Dear Sir/Madam, RE: REC13/0015. One lot into 4 lots at 55 Lake Macdonald Drive Draft Conditions We are writing to respond to parts of the Draft Conditions dated 12-06-13, other responses are provided separately. Draft Condition 6 and 11 We have provided a proposed re-wording for conditions 1 and 11 as follows. Driveways 1. A sealed access driveway must be provided from Lake Macdonald Drive to Lots 1-4 and te-the-prepesed_bieretention-_basin. The works must be generally in accordance with Drawing No 1225-02 Rev A titled Stage 1 Four Lots Master Civil Layout Plan 1 dated May 2013 as prepared by Callaghan and Toth. The works must be undertaken in accordance with an Operational Works approval and must include in particular: (a) a driveway crossover in accordance with IPWEAQ standard drawing SEQ R- 050 HYDRAULICS AND WATER QUALITY 11. The site must be provided with a stormwater drainage system connecting to a lawful point of discharge. The works must be undertaken in accordance with an Operational Works approval and the Queensland Urban Drainage Manual), and must include in particular: (a) stormwater quantity management devices of a size and location generally in accordance with those shown in the of the Stormwater Treatment and Water Quality Management Plan listed in this Decision Notice (b) collection and discharge* of stormwater to the drainage line, including the provision of Level 2 interallotment drainage for proposed Lot 1 — 4 with associated interallotment drainage easements (c) the use of gravity stormwater drainage and not surcharge pits. *(Refer to Advisory Note)A stormwater quality treatment system must be provided for the development. The works must be undertaken in accordance with an Operational Works approval and the Bioretention Technical Design Guidelines (Water by Design) and must include in particular: (a) stormwater quality treatment devices of a size and location generally in accordance with those shown in Section 4 of the of the Stormwater Treatment and Water Quality Management Plan listed in this Decision Notice (b) bioretention devices which: (i) are designed generally in accordance with IPWEQA Standard Drawing No. WSUD-001 X:WOBSICT Projects in progress\1225 30 lots lake MacDonald Drive\Correspondence\REC Info request response.doc
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
(iv) are designed to ensure that flows which exceed the treatment capacity of the device avoid damaging of the filter media or subjecting the filter media to excessive sediment loads. (v) are provided with a free-draining outlet from the sub-soil drainage system The current Bio-Retention Guidelines (Water By Design, Version 1 October 2012) states that a coarse sediment forebay is not required for catchments less than 2 Hectares (Table 14 on page 69). The catchment area is 0.372 Ha and therefore a sediment forebay is not required and should be deleted from Condition 11 as shown above. It then follows that an access driveway right down to the bio-retention basin to remove sediment from a forebay is not required when a forebay is not installed. Figure 34 of the Bio-Retention Guidelines (Water By Design, Version 1 October 2012) sets out access track requirements for a forebay, however without a forebay these requirements are not applicable and we request that Condition 1 should be revised as shown above. Yours faithfully, Callaghan & Toth A Haynes BE Civil (Hons) RPEQ MIEAust CPEng Please view www.callaghanandtoth.com.au for all information on our company profile and terms and conditions for services rendered Cc Alex Mc Williams Max Watterson X:WOBSICT Projects in progress\1225 30 lots lake MacDonald Drive\Correspondence\REC Info request response.doc
Used in these records
Draft Condition Response CTRelated documentApplication case desk ↗
About this file
- File size
- 344 KB (small file)
- File type
No other editions are linked here.