Original source · versioned page text
Appendix G - Code Responses
LANDSLIDE HAZARD OVERLAY CODE
Performance Outcomes Acceptable outcomes Applicant’s Comments
The extent of filling or excavation
is revegetated immediately
following completion of the works.
AO3.6
Any building, including any associated
car parking structure:-
1. has a maximum undercroft height
at the perimeter of the building of 3
metres above ground level; or
2. incorporates landscape screening
for the full height of any undercroft
higher than 3 metres
above ground level at the
perimeter of the building.
Editor's note- Vertical battens are also useful
to enclose the undercroft area.
AO3.7
On sloping sites roof lines are generally
parallel with contours of the land and roof pitch
does not exceed 15 degrees.
PO4 AO4.1 Complies.
Development on sloping sites provides safe Driveways are not steeper than 20% for more
and efficient access for vehicles and than 20 metres or one quarter of their length,
pedestrians whichever is the lesser, and not steeper than
25% in any location.
AO4.2
Vehicle turning areas are provided at the end Complies.
of driveways so that it is not necessary to