Original source · versioned page text
Appendix G - Code Responses
SUSTAINABLE DESIGN CODE
Performance outcomes Acceptable outcomes Applicant’s Comments
Building design
PO8 AO8.1 Performance outcome:
Development - Development provides a detailed assessment The proposed development complies with the
including supporting documents, requirements PO8 through the following:
1. orientates buildings and windows demonstrating the means by which the design The development incorporates windows
to make the most of prevailing meets PO8. to capture prevailing winds and
winds, natural ventilation and cross enhance cross ventilation;
breezes; AO8.2 Weather protection and sun shading
2. maximises shade to east and west Development demonstrates a measured (including eaves and overhangs) are
walls; equivalent to a 5-star Green Star rating. incorporated into the facades of the
3. contains an open and permeable buildings) (Refer to Appendix B);
built form that connects indoor and Editor’s note—The publications QDesign and The proposal includes generous
outdoor spaces in an integrated QCompanion, prepared by the State of landscaping treatments, to provide
design; Queensland, provide climate responsive natural shading where possible;
4. retains existing vegetation and design principles for development in south east The development incorporates passive
natural shading where possible; Queensland. Council encourages building and building design to mitigate reliance of
5. incorporates passive building landscape designers to incorporate best mechanical cooling and heating
design to reduce the need for practice outcomes described in these techniques, by embracing natural
auxiliary heating and cooling; publications to help development comply with breezes and light;
6. uses low toxic internal and external PO8. Each habitable room includes a
building materials; minimum of 2 openings through the use
7. uses natural light rather than of windows;
artificial light, and may include Each dwelling includes a minimum
skylights, atriums and light wells; 2.7m floor to ceiling height;