Original source · versioned page text
Council further RFI Issue (1)
Very large file (106 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 69, section 1. The text section number identifies this passage in the reader.
SH1 SH1
M1
HT TR TP4 HT
SC1
2,100
2,100
2,100
2,100
TR SC1
TL1 TP4 TL1 SC1
HT
VTY02 PB
1,220
1,200
1,200
1,200
SH1 TL1 VTY02
04 VTY02 VTY02
775
775
FW1
TL1 FW2 FW2 TL1
W.11
03
ENS.3
01 ST
FW2 WD.8.10
TR
TL1 02 ST
ENSUITE TYPE 3 PLAN 01 ENS.3 02 ENS.3 03 ENS.3 04 ENS.3
Scale 1:50 Scale 1:50 Scale 1:50 Scale 1:50 Scale 1:50
MRPB
MRPB RAKED CEILING
RAKED CEILING UNDER STAIR
UNDER STAIR MRPB
RAKED CEILING
TRH WC
UNDER STAIR
04
PDR
03
WD.8.10
01 M1
02
TP3
TL1 S3
1,180
M1
TRH TRH
900
900
900
S3
775
WC TL1 WC TL1
TL1
POWDER ROOM TYPICAL 01 PDR 02 PDR 03 PDR 04 PDR
Scale 1:50 - Scale 1:50 - Scale 1:50 - Scale 1:50 - Scale 1:50
PB HR HR
HR
HWU
655 655
450
CPB CPB BT01 BT01
BT01
900
2,300
TP1 TP1
600
600
S4 CPB CPB
S4 HWU
04 BT01
1,900
BT01
D.02
LDY.1
03 01
WD.8.10 WM LM01
800
LM01
900
D.05
02
CPB
BT01
WM S4
300
650
100
100
BT01 700 700 450 655 655
1,400 650
TP1 650
LAUNDRY TYPE 1 PLAN 01 LDY.1 02 LDY.1 03 LDY.1 04 LDY.1
Scale 1:50 Scale 1:50 Scale 1:50 Scale 1:50 Scale 1:50
HR
520
BT01
TP1
2,400
600
BT01
LDY.2
02
WD.8.10
SHELF
900
01 WM DRY
100
LM01 LM01
890 1,240 860
LAUNDRY TYPE 2 PLAN 01 LDY.2 02 LDY.2
Scale 1:50 Scale 1:50 Scale 1:50
H
Notes:
B L A C K Project: Drawing Title: Project No. Drawn By Drawing No.
Rev Date Description Use figured dimensions in preference to scale. Contact information:
1. These drawings represent a concept design for preliminary cost analysis (MAY 2023) and are NOT FOR CONSTRUCTION J 3/11/2023
07/07/2023 VM REVISION All dimensions to be varified and checked on
E 9/11/2023 VM REVISION site. These designs, drawings, specifications
PO Box 781 Tewantin Q 4565 79 - 83 Eumundi Noosa Road JOINERY ELEVATIONS - WET 202327 PT WD.8.10
2. The drawings and diagrams provided herewith are NOT FOR CONSTRUCTION OR BUILDING APPROVAL and to be used for preliminary D&C tendering only. Architect Registration # 5386 QLD
and the copyright thereof are the property of For CAPITAL PRUDENTIAL
F 24/11/2023 Council further RFI Issue
W O O D Ph: 0416 037 424 AREAS
Structure & Services coordination has not been undertaken. G 1/12/2023 Council further RFI Issue
Blackwood and must not be used, retained or
79 - 83 EUMUNDI NOOSA ROAD & 26 Scale Date Project Stage Revision
copied without the written authority of [email protected]
H 5/12/2023 Council further RFI Issue Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au HEADLAND DRIVE, NOOSAVILLE QLD 4566 @ A1 5/12/2023 Concept H
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.