Council further RFI Issue (1)

of 120

Page text shows just the words. Original shows the document exactly as it was published.

Very large file (106 MB): the original may take a few minutes to open or download. The page text below is quick to read.

Original PDF page 3, section 1. The text section number identifies this passage in the reader.

GENERAL NOTES:

DESCRIPTION:                                                               PENETRATIONS                                                                SOUND TRANSMISSION AND WALL / FLOOR INSULATION                            EXTERNAL WALLS                                                                            LANDSCAPING (Hardscape & Softscape)
Proposed Redevelopment. New building works to consist of mixed             All penetrations through fire rated members must be fire protected          The floors must have an Rw + Ctr (airborne) not less than 50 and an       All external walls that are to be 190mm thick Blockwork shall be                          Refer to Landscape Architect's drawings for details.
use building comprising of 2 storeys of residential units & 2 Storey       in accordance with a tested prototype to maintain the fire resistance       Lnw + Ci (impact) not more than 62 if the floor separates sole            reinforced and solid core filled concrete blockwork in accordance
                                                                                                                                                                                                                                                                                                                           POOL
Townhouses.                                                                of the element being penetrated in accordance with NCC clause               occupancy units or a sole occupancy unit from a plant room, lift          with Structural Engineer's drawings. Provide a proprietary type
                                                                                                                                                                                                                                                                                                                           A pool and spa safety barrier must be provided in accordance with
                                                                           3.12-3.15.                                                                  shaft stairway, public corridor, public lobby or the like or parts of a   Elastomeric waterproof render and membrane paint finish to all
DEVELOPMENT APPROVAL:                                                                                                                                                                                                                                                                                                      Queensland Development Code MP3.4, AS 1926.1 & 2 and the
                                                                                                                                                       different classification. Install an approved and tested / certified      walls. Render and paint finishes to be applied by an approved
Development Approval is yet to be given. Conditions of Approval            DISABILITY PROVISIONS                                                                                                                                                                                                                           Building Act (Chapter 8). Resuscitation signs must be mounted in
                                                                                                                                                       proprietary type applied acoustic underlay to all internal tiled areas    applicator in accordance with manufacturer's requirements.
are to be adhered to when known.                                           A lift or ramp to serve upper levels is not mandatory (except where                                                                                                                                                                             prominent positions.
                                                                                                                                                       where ceilings are not installed to units below.
                                                                           required to satisfy the items above) however where installed, access                                                                                  EXPANSION / CONTROL JOINTS                                                                A warning sign must be provided to serve the property prior to the
EXISTING BUILDING:                                                                                                                                     The walls separating sole occupancy units must have an Rw + Ctr
                                                                           must be provided to the entrance door of every unit served by the                                                                                     Provide expansion / control joints in accordance with Structural                          construction of the pool or spa in accordance with Section
There are 4 Existing Houses on sites. The Existing Houses are to be                                                                                    not less than 50. A wall must have an Rw (airborne) not less than 50,
                                                                           lift. Access must also be provided to and within rooms or spaces for                                                                                  Engineer's drawings. Fill expansion joints with a proprietary type                        233 of the Building Act 1975. The warning sign must be displayed
Demolished In a safe & compliant manner.                                                                                                               if it separates a sole occupancy unit from a plant room, lift shaft,
                                                                           use in common by the residents (e.g. including a cooking facility,                                                                                    water barrier system suitable for location. Install in accordance with                    until a building certifier has provided a certificate in the approved
                                                                                                                                                       stairway, public corridor, public lobby or the like, or parts of a
SAFETY IN DESIGN:                                                          sauna, gymnasium, swimming pool, common laundry, games room,                                                                                          manufacturer's requirements.                                                              form stating the pool is a complying pool. The sign must warn
                                                                                                                                                       different classification.
A saftey in design report has been prepared to Safe Design                 individual shop, eating area, or the like) that are served by the lift or                                                                                                                                                                       members of the public in the vicinity of the land that a swimming
                                                                                                                                                       A wall that separates a bathroom, sanitary compartment, laundry or        FORMWORK / CONCRETE
Australia. Builder & contractors shall familirise themselves with this     ramp.                                                                                                                                                                                                                                           pool is under construction on the land and that there is potential
                                                                                                                                                       kitchen in one sole occupancy unit from a habitable room (other           All exposed concrete surfaces and concrete surfaces with applied
report prior to Demolition works commencing.                               Access is required to and within any level containing accessible                                                                                                                                                                                danger to young children accessing the land. The sign must be
                                                                                                                                                       than a kitchen) in an adjoining unit or separates a sole occupancy        render or paint finish shall be formed with minimum class 2
                                                                           carparking spaces. In a class 7a carpark, PWD car spaces in                                                                                                                                                                                     placed on, or within 1.5m of the road frontage for the land and be
DEMOLITION:                                                                                                                                            unit from a plant room or lift shaft must be of discontinuous             formwork to achieve uniform quality.
                                                                           accordance with AS 2890.6 are required at a ratio of 1:100.                                                                                                                                                                                     mounted so that the bottom of the sign is at least 300mm above
Contractor responsible to assess existing site conditions and allow                                                                                    construction, i.e. providing a minimum 20mm cavity between 2
                                                                           Access is required to and into swimming pools with a total                                                                                            CONCRETE COLUMNS                                                                          ground level. The sign must be visible from the road and be made
for demolition and removal of material as indicated on the                                                                                             separate leaves and for masonry, where wall ties are required to
                                                                           perimeter greater than 40m except where the pool is for the                                                                                           All concrete columns shall be reinforced concrete in accordance                           of weatherproof material. Lettering on the sign must be not less
drawings. This includes existing floor, wall and roofing material.                                                                                     connect leaves, the ties are of the resilient type and for other than
                                                                           exclusive use of a sole occupancy unit in a class 2 building (refer                                                                                   with Structural Engineer's drawings. Class of finish to formwork                          than 50mm in height and in a bold style.
Contractor responsible to assess presence of asbestos and allow for                                                                                    masonry, there is no mechanical linkage between leaves except at
                                                                           NCC Clause D3.10).                                                                                                                                    columns to be class 2. Provide a proprietary type render and                              Prior to filling the pool to a depth exceeding 300mm the building
safe removal of hazardous materials.                                                                                                                   the periphery.
                                                                           Every passenger lift must comply with NCC Clause E3.6 (disability                                                                                     waterproof membrane paint finish to all columns. Render and paint                         certifier must inspect and provide confirmation (form 17) that the
Measures are to be taken to minimize dust & noise disruption such                                                                                      If a duct, soil, waste or water supply pipe including a duct or pipe
                                                                           requirements).                                                                                                                                        finishes to be applied by an approved applicator in accordance with                       pool safety barriers are in accordance with the Building Act.
as providing hoarding separation between new construction works                                                                                        that is located in a wall or floor cavity, serves or passes through
                                                                           For narrow accessways, passing spaces and turning spaces must be                                                                                      manufacturer's requirements.                                                              Backwash and excess pool water must be drained in accordance
and existing footpath & Roadway which are maintained during the                                                                                        more than one sole occupancy unit, the duct or pipe must be
                                                                           considered in accordance with NCC D3.3 (20m intervals).                                                                                                                                                                                         with Local Authority requirements.
construction period.                                                                                                                                   separated from the rooms of any sole occupancy unit by                    TANKING
                                                                           Braille signage is required to common area sanitary facilities.                                                                                                                                                                                 In accordance with NCC Clause G1.1(c), a water recirculation
Demolition contractor to be familiar with existing operational in                                                                                      construction with an Rw + Ctr (airborne) not less than 40 if the          Provide proprietary type waterproof membrane tanking system to
                                                                                                                                                                                                                                                                                                                           system in a swimming pool with a depth of water more than 300mm
ground and overhead infrastructure which traverses the site and            STAIRS, HANDRAILS, AND BALUSTRADES                                          adjacent room is a habitable room (other than a kitchen) and not          all balconies, terraces, blockwork window reveals, planters, slabs
                                                                                                                                                                                                                                                                                                                           must comply with AS 1926.3. A spa pool must comply with AS
take steps to protect during construction.                                 The stairways must be not less than 1000mm in clear width.                  less than 25 if the adjacent room is a kitchen or non- habitable          over carpark walls, retaining walls and the like to ensure a
                                                                                                                                                                                                                                                                                                                           1926.3 except the specified distance between two outlets
Extent of demolition to include all above and below ground                 Stairways must have constant riser dimensions not greater than              room.                                                                     watertight finish. To be installed in accordance with manufacturer's
                                                                                                                                                                                                                                                                                                                           connected to a common line may be not less than 600mm. All
structure sufficient to allow construction of new building.                190mm and constant going dimensions not less than 250mm. Not                If a storm water pipe passes through a sole occupancy unit, the pipe      specifications and shall be applied by an approved applicator.
                                                                                                                                                                                                                                                                                                                           fences & balustrades enclosing swimming pool & overflow pool to
                                                                           more than 18 risers are permitted within a single flight. Stair treads      must be separated from the rooms of any sole occupancy unit by
DRAWINGS                                                                                                                                                                                                                         WATERPROOF CONCRETE MEMBRANE                                                              comply with NCC & AS 1926.1 & AS 1926.2.
                                                                           must have a non-slip finish and a contrasting nosing.                       construction with an Rw + Ctr (airborne) not less than 40 if the
Do not scale off drawings. Dimensions take preference over scale.                                                                                                                                                                Reinforced concrete roof slabs are to be poured with integral fall to
                                                                           Where it is possible to fall greater than 1000mm to an adjacent             adjacent room is a habitable room (other than a kitchen) and not
                                                                                                                                                                                                                                 drains. Minimum fall to drains shall be 1:150. Finish with proprietary
SET OUT                                                                    surface, balustrading must be provided in accordance with Clause            less than 25 if the adjacent room is a kitchen or non-habitable room.
                                                                                                                                                                                                                                 type trafficable membrane, to be installed in accordance with
Builder to confirm the set out and all levels and dimensions on site       D2.16 of the NCC with balustrades extending not less than 1000mm            Prior to construction, details of the proposed construction method
                                                                                                                                                                                                                                 manufacturer's requirements and shall be applied by an approved
prior to the commencement of the building works.                           above floor level or 865mm above the nosing of a stair. Balustrades         to achieve this requirement must be submitted to the satisfaction of
                                                                                                                                                                                                                                 applicator. Provide all necessary accessories, covers, laps, etc. to
                                                                           must not have any gaps that would permit a 125mm sphere to                  the Building Certifier.
CONSTRUCTION                                                                                                                                                                                                                     ensure a watertight finish. Application shall be such that ponding
                                                                           penetrate. Where it is possible to fall greater than 4m to an adjacent      A flexible coupling must be used at the point of connection
All construction shall comply with the requirements of the Building                                                                                                                                                              does not occur. Colour of membrane shall be selected.
                                                                           surface, balustrades must have no climbable elements between                between the service pipes in a building and any circulating or other
Code of Australia 2019 Volume 1 for class 2, 7a Building. Type A           150mm and 760mm above floor level (including hose cocks, A/C                pump.                                                                     EXTERNAL APPLIED EXTERNAL FINISHES
construction. Building Act 1975. Building Regulations 2006 and all         condensers on balconies). Where it is possible to fall greater than                                                                                   All applied external membranes / finishes shall be in accordance
referenced Australian Standards.                                                                                                                       HEALTH AND AMENITY
                                                                           4m out of a window, balustrades must extend to a height not less                                                                                      with NCC Requirements and AS1530.1 for Non-Combustibility.
                                                                                                                                                       Toilet doorways within 1200mm of the pan must have lift off hinges,
ENGINEERING                                                                than 865mm above floor level to protect that window. Staunchions
                                                                                                                                                       slide or swing outwards.                                                  WATERPROOFING INTERNALLY
To be read in conjunction with Engineer's drawings and soil report.        to be @ 1250mm crs. max.
                                                                                                                                                       A storm water drainage management system in accordance with               Waterproofing of internal wet areas shall comply with AS 3740.
Refer to engineering drawings for structural design, footing and           EXTERNAL STAIRWAYS                                                          AS/NZS 3500.3 must be provided (building drainage and civil               Provide a proprietary type liquid or sheet membrane system and
slab, tie down, bracing and all structural details.                        All external stairways shall be in accordance with part D1.8 of the         drainage). The system must be designed and certified by an RPEQ           fall to wastes.
CIVIL ENGINEERING                                                          NCC and AS 1428.1. Provision for future upgrade to stairways to             Engineer as complying with the NCC and AS/NZS 3500.3. Any
                                                                                                                                                                                                                                 TIMBER
To be read in conjunction with Engineer's drawings. Refer to               meet AS 1428.1 requirements, tactile indicators, perimeter handrail         cutting or filling of the site, or construction of retaining walls or
                                                                                                                                                                                                                                 All timber to be in accordance with the NCC, Standards Australia AS
engineers documents for extent of civil works.                             to stairs.                                                                  other structure on site, shall not jeopardize any existing overland
                                                                                                                                                                                                                                 1684.1 and Engineer's Drawings and Termite protected to AS
                                                                                                                                                       flow drainage system or cause ponding or nuisance storm water.
SEWER CONNECTION                                                           EXIT SIGNS AND EMERGENCY LIGHTING                                                                                                                     3660.1.
                                                                                                                                                       Hot water, warm water & cooling water systems in a building must
All plumbing points to be connected to sewer as per council                Provide illuminated exist signs and lighting to comply with Section
                                                                                                                                                       be installed in accordance with AS/NZS 3666.1.                            STEELWORK
requirements and in accordance with Hydraulic and Civil                    E4.2 and E4.7 of the NCC and AS 2293 part 1. Refer to Electrical
                                                                                                                                                       Roof coverings must be provided in accordance with Clause F1.5 of         All steelwork, fittings and fixtures shall be hot dipped galvanised,
Engineer's drawings.                                                       Engineer's drawings.
                                                                                                                                                       the NCC and AS 1562.1.                                                    stainless steel or of a corrosion resistant material or as noted
STORMWATER                                                                 LIFT                                                                        All wet areas must be waterproofed in accordance with AS 3740.            otherwise. Select paint finish.
All stormwater shall discharge as per council requirements and in          A stretcher facility must be provided to serve the lifts and be able to     The floor of each bathroom and laundry located above another sole
                                                                           accommodate a raised stretcher with a patient lying on it                   occupancy unit or public space must be graded to permit drainage          PLASTERBOARD FINISH
accordance with Hydraulic and Civil Engineer's drawings.
                                                                           horizontally by providing a clear space not less than 600mm wide x          to a floor waste.                                                         Plasterboard to be finished to level 4 finish and shall be installed in
POWER CONNECTION                                                           2000mm long and 1400mm high above the floor level.                          Artificial lighting must be provided to the common areas of the           accordance with AS 2589.1.
Connect mains supply to meter panel via underground connection             A warning sign against the use of the lift in a fire must be provided       building in accordance with the NCC (including the energy                 ALUMINIUM AND GLAZING
in accordance with Electrical Engineer's requirements.                     in accordance with Clause E3.3 of the NCC. Fire Service controls            efficiency provisions) and AS 1680.0.                                     Shall be in accordance with AS 2048 & AS 1288, and suit site terrain
TERMITE PROTECTION                                                         must be provided to the lift in accordance with AS 1735.2 or                All toilets and/or wet areas not provided with adequate natural           category. Aluminium framing shall be select powdercoated unless
Provide an approved proprietary type termite protection barrier to         Appendix A of AS 1735.1.                                                    ventilation must be exhausted to outside in accordance with AS            noted otherwise.
concrete slab and retaining walls as per manufacturer's                    Lifts to comply with Clause E3.6 of the NCC, facilities for people with     1668.2
                                                                           disabilities.                                                               Habitable rooms must be served by natural lighting through glazed         TILING / CONCRETE FLOORS
specification and in accordance with AS 3660.1 and the NCC.
                                                                           Access to lift pits must comply with NCC Clause D1.17. Access to lift       windows having an area not less than 10% of the floor area they           Concrete floor finish tolerance shall be class B. Floor grinding
VERMIN PROOFING                                                            pits may be through the lowest landing doors where the pit is not           serve in accordance with NCC Clause F4.1. Natural ventilation must        and/or floor topping with flooding of levelling compound shall be
Ensure all soffits, eaves overhangs and under floor areas are vermin       more than 3m deep, otherwise compliance with NCC Clause                     be provided by permanent windows, doors or other devices which            allowed for to ensure suitable surface finish for the laying of floor
proof and bird proofed. This includes both new work and existing           D1.17b is required.                                                         can be opened having an aggregate opening or openable size not            tiles.
building.                                                                  Doors shall be FRL -/60/- Fire doors to comply with NCC section             less than 5% of the floor area of the room required to be ventilated.     FLOOR SURFACES
Principal Contractor to engage suitably qualified Contractor to            and AS 1735.1.
                                                                                                                                                       ENERGY EFFICIENCY                                                         Must be suitable to prevent slips (Standards Australia Handbook
assess the project and provide recommendation and quote to
                                                                           FIRE HOSE REELS, HYDRANTS AND FIRE SPRINKLERS                               The building must be constructed to satisfy the energy efficiency         197 & AS/NZS 4586), trips and falls and be impervious to liquids
supply and install necessary fixtures and fittings to control both land
                                                                           A fire hydrant system must be provided to serve the proposed                provisions of Section J of the NCC.                                       where spillage or wash down is likely. Floors must be suitably
and air born vermin.
                                                                           development in accordance with AS 2419.1 and shall be provided              ‘Energy efficient lighting’ for a minimum of 80 per cent of total fixed   graded to drain off liquids where spillage or wash down is likely to
FIRE RESISTANCE                                                            where indicated on Hydraulic and Architectural drawings, except as          internal lighting must be provided. ‘Energy efficient lighting’ is        occur.
External & internal fire separating walls must extend to the fire rated    otherwise permitted by the approved Fire Engineering Report.                lighting with a minimum output of 27 lumens per watt and excludes         PAINT SPECIFICATION
slab above or to the underside of the non-combustible roof                 Provision must be made for the disposing of fire hydrant test water         a lamp used in a bathroom for the purposes of radiating heat.             Use Resene or other approved supplier, Specification Sheets for
covering and be sealed at that roof junction with compressed               to a suitable drain for the purpose of flow testing.                        Any hard-wired air-conditioners installed must have an EER of at          substrates preparation and application guidelines for instruction on
mineral fibre wool. Any eaves must be protected to ensure that the         A fire hose reel system must be provided to serve the development           least 2.9. Energy Efficiency Ratio (EER) means the tested average         the expected levels of preparation & application of painted
fire separation between the units is maintained.                           in accordance with NCC Clause E1.4 and AS 2441. Fire hose reels             energy efficiency ratio for cooling as specified in ‘AS/NZS 3823.2        surfaces.
Bedroom windows facing the common walkway must have a sill                 must be located within 4m of an exit. Any system valve which can            Performance of electrical appliances - airconditioners and heat
height not less than 1500mm above finished floor level and the wall        isolate flow in the fire hose reel water supply main must be secured        pumps - energy labelling and minimum energy performance                   POWDERCOATING
below the window must have a minimum 1hour fire resistance level           in the open position by a padlocked metal strap and labelled with           standard (MEPS) requirements’.                                            Preperation & application of Aluminium to be powdercoated shall
to satisfy NCC Clause C3.11.                                               an engraved non- ferrous tag with 8mm upper case wording ‘FIRE              All shower roses must have a minimum 3-star Water Efficiency              be to AAMA2604, AS4312 & AS3715
The fire hazard properties of any material (including carpets, vinyls      SERVICE VALVE- CLOSE ONLY TO SERVICE FIRE HOSE REELS’. Fire                 Labelling and Standards rating. Water Efficiency Labelling and            DOOR HANDLES
& laminates) or assembly to comply with specification C1.10a of the        hose reel cabinet signage must have 50mm high capital contrasting           Standards (WELS) - references the Australian Government’s                 Provide lever door handles located 900-1100mm above floor level
NCC (if a floor material, floor covering or a wall/ceiling lining) or      letters ‘FIRE HOSE REEL’.                                                   labelling standards scheme for water efficient products.                  operable with a single hand.
comply with specification C1.10 if not a material applicable under         A sprinkler system must be provided to serve the basement in                Toilet cisterns must have a dual flush function and have a minimum
specification C1.10a.                                                      accordance with NCC Clause E1.5 and AS2118.1 except as                      4-star Water Efficiency Labelling and Standards rating and are            LIGHT SWITCHES
Spandrels must be provided to serve the building in                        otherwise permitted by the approved Fire Engineering Report.                compatible with the size of the toilet bowl to allow for proper           Provide light switches close to doorways and installed between
accordance with NCC Clause C2.6.                                                                                                                       functioning of the toilet.                                                900- 1100mm above floor level.
Electrical supplies to emergency equipment must be fire separated          FIRE SMOKE DETECTION AND ALARM SYSTEM
                                                                                                                                                       Tap ware must have a minimum 3-star Water Efficiency Labelling            VEHICULAR ACCESS TO CARPARK
from the building in accordance with Clause C2.13 of the NCC. The          Provide fire smoke detection and alarm system in accordance with
                                                                                                                                                       and Standards rating for taps serving laundry tubs, kitchen sinks         Provide entry signage to carpark stating maximum clearance to
main switchboard must be fire separated from the remainder of the          AS1670.1, and Electrical Engineer's drawings.
                                                                                                                                                       and basins.                                                               carpark 2.2 metres. Provide flexible striker bars over entry down to
building by 120/120/120 fire resistant construction with the               FIRE EXTINGUISHERS                                                          Each meterable premises must have an electricity sub-meter                max. 2.2 metre height to comply with AS 2890.1 requirements.
doorway protected by a self closing fire door having a fire                Portable fire extinguishers must be provided in accordance with             installed which measures only the electricity supplied to that
resistance level not less than -/120/30. Any electrical conductors         NCC Clause E1.6 and AS 2444. Provide a CO2 portable fire                    meterable premises in accordance with QDC MP4.1. The electricity          CARPARKING
within the building that supply the main switchboard must be fire          extinguisher to serve each main switch board in the basement car            sub-meter must be installed in a common area, and be free of              Carparking to comply with AS 2890.1.
protected in accordance with Clause C2.13.                                 park. Provide a 3A40B(E) portable fire extinguisher adjacent to each        hindrance or obstruction to a person authorised to read and/or
Every doorway that opens onto the External stairways must be                                                                                                                                                                     DRIVEWAY
                                                                           fire hose reel.                                                             maintain the electricity sub-meter. A meter label identifying which
protected by -/60/30 fire doors that are self closing in accordance                                                                                                                                                              Shall be in accordance with AS 2890.1 and Structural and Civil
                                                                                                                                                       meterable premises it is associated with must be affixed or located
with NCC Clause C3.8a(ii) & (iii).                                         SMOKE ALARMS                                                                                                                                          Engineer's drawings.
                                                                                                                                                       adjacent to the electricity sub-meter for each meterable premises.
The lifts must be served by -/60/- fire doors complying with               Provide hard wired smoke alarms in accordance with part E2 of the
                                                                                                                                                       Glazing must be provided in accordance with AS1170, AS1288 &              MAINTENANCE ACCESS
AS1735.11 that are set to remain in the closed position.                   NCC and AS 3786. Provide smoke detection systems in
                                                                                                                                                       AS2047.                                                                   Provide building maintenance access complying with Occupational
All penetrations through fire rated members must be fire protected         accordance with AS 1670 and Electrical Engineer's drawings.
                                                                                                                                                                                                                                 Health and Safety 2004 Codes of practice and AS 1891.4. Where a
in accordance with a tested prototype to maintain the fire resistance                                                                                  BUILDING SEALING
                                                                           CARPARK AND UNIT MECHANICAL VENTILATION                                                                                                               person is exposed to the hazard of falling from a building or
of the element being penetrated in accordance with NCC Clauses                                                                                         Window and doors; exhaust fans; construction of roofs, walls and
                                                                           The car park exhaust system must comply with Clause 5.5 of                                                                                            structure while cleaning or maintenance work is being carried out, a
C3.12 to C3.15.                                                                                                                                        floors shall be in accordance with BCA part J3.4, J3.5 and J3.6.
                                                                           AS1668.1 with the controls for the QFES located to the satisfaction                                                                                   system design to prevent such falls must be used. Where safety belt
An opening in a wall providing access to a garbage shaft must be           of the QFES (typically at the car park vehicular entry point).              ROOF INSULATION                                                           anchorage points are used they must be positioned on the building
protected by a door or hopper of non-combustible construction.             Provide a mechanical ventilation system to all ensuites, bathrooms          R X.X insulation in ceiling space to all Roofs. Refer NRG Efficient       or structure so that a lifeline or safety harness may be attached
                                                                           and laundries in accordance with Mechanical Engineer's                      Homes report.                                                             before proceeding to a point where it is possible to fall.
                                                                           documents and section F4 of the NCC and AS 1668.2 and AS/NZ                                                                                           Anchorage points for the attachment of safety harnesses must
                                                                                                                                                       WALL INSULATION
                                                                           3666.1                                                                                                                                                comply with AS 2626.
                                                                                                                                                       R X.X insulation to External Walls. Refer NRG Efficient Homes
                                                                                                                                                       report.




Notes:
                                                                                                                                                                                                                                                                                                                                                                            B L A C K                                                    Project:                              Drawing Title:   Project No.   Drawn By        Drawing No.
                                                                                                                                                          Rev   Date         Description                                                                                                                Use figured dimensions in preference to scale.                                               Contact information:
1. These drawings represent a concept design for preliminary cost analysis (MAY 2023) and are NOT FOR CONSTRUCTION                                        K     3/11/2023    VM REVISION                                                                                                                All dimensions to be varified and checked on
                                                                                                                                                          E     9/11/2023    VM REVISION                                                                                                                site. These designs, drawings, specifications
                                                                                                                                                                                                                                                                                                                                                                                                     PO Box 781 Tewantin Q 4565          79 - 83 Eumundi Noosa Road            GENERAL NOTES    202327        PT              WD.0.03
2. The drawings and diagrams provided herewith are NOT FOR CONSTRUCTION OR BUILDING APPROVAL and to be used for preliminary D&C tendering only.                                                                                                                                                                                                                                                      Architect Registration # 5386 QLD
                                                                                                                                                                                                                                                                                                        and the copyright thereof are the property of                                                                                    For CAPITAL PRUDENTIAL
   Structure & Services coordination has not been undertaken.
                                                                                                                                                          F
                                                                                                                                                          G
                                                                                                                                                                24/11/2023
                                                                                                                                                                1/12/2023
                                                                                                                                                                             Council further RFI Issue
                                                                                                                                                                             Council further RFI Issue
                                                                                                                                                                                                                                                                                                        Blackwood and must not be used, retained or                         W O O D                  Ph: 0416 037 424
                                                                                                                                                                                                                                                                                                                                                                                                     [email protected]     79 - 83 EUMUNDI NOOSA ROAD & 26       Scale            Date          Project Stage   Revision
                                                                                                                                                                                                                                                                                                        copied without the written authority of
                                                                                                                                                          H     5/12/2023    Council further RFI Issue                                                                                                  Blackwood.                                       a r c h i t e c t u r e   &   d e s i g n   www.blackwoodarchitecture.com.au    HEADLAND DRIVE, NOOSAVILLE QLD 4566   1:100 @ A1       5/12/2023     Concept         H
Log in to download the original file

Council further RFI Issue (1).pdf · 106 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.