Performance outcomes Acceptable outcomes Compliance
times for fire fighting purposes. Hydrant and Vehicle Access
Guidelines for Residential,
OR Commercial and Industrial Lots,
Water Supply Code of Australia
AO3.2 South East Queensland Service
Where there is no available Providers Edition Version 1.3
reticulated water supply, the (August 2019) and AS2419.1:2021
premises has: Fire Hydrant Installations or, to
an accessible dam, swimming pool the extent that there is any
or water tank available for fire difference, UnityWater’s Pr11029
fighting purposes with an onsite - Fire Hydrant Spacing and
water volume of not less than Location Technical Note (2023).
5,000 litres; and If reticulated water supply is not
a water supply outlet pipe 50 available for proposed lot 1, then
millimetres in diameter fitted with a a dedicated static supply is
standard fire brigade fitting required to be established and
connected to the water supply maintained solely for firefighting
(other than where the water supply purposes. The dedicated static
is in a swimming pool or dam). supply shall have the following
characteristics:
• have an on-site volume of at
Editor’s Note—Water supply
least 5000 litres.
capacity for fire fighting purposes is
• be located within 10m of each
in addition to water supply capacity
habitable building but at least
for other uses and activities on the
10m from any areas of
premises. potential fireline intensity or
other potential sources of fuel.
• be located either below ground
level or of non-flammable
construction.
• be located away from
flammable vegetation and
other combustible objects.
• have a take-off connection at a
level that allows access by
firefighters.
• allow medium rigid vehicle (15
tonne fire appliance) clear
access within six metres of the
tank.
• be provided with rural fire
brigade tank fittings of a
50mm valve and male camlock
coupling and, if underground,
27 | 31
Document Set ID: 23448646
Version: 1, Version Date: 13/01/2025