0
700
7685
7.20m7-Lln ROOF RL16.59m
GENERAL NOTES 4-LoL
1-Cav 4-Lln
:
ET
PROPOSED TOPPING AREAS TO BE GRADED/DRAINED TO PREVENT WATER DISCHARDE INTO NEIGHBOURING PROPERTIES.
:
WM
:
Admin
:
AN IN-GROUND AUTOMATIC DRIP IRRIGATION SYSTEM TO BE INSTALLED TO ALL GARDEN AREAS. 1-Cav WS WS WS WS WS Waste Room
8x
1500
RE
0
TIMBER EDGING TO BE 75mm X 25mm TREATED PINE SECURED TO 30mm LONG TREATED PINE STAKES AT NOM 1200mm x 5 .4
2 .4 0
S P ACE Bike
CAR
SPACINGS WITH GALVANISED SCREWS AND INSTALLED TO ALL JUNCTINS BETWEEN GARDEN BEDS, LAWN AND COMPACTED tug Spaces
Disabled /
TOPPING AREAS. Trade Hub 1 Trade Hub 2 Trade Hub 3 Trade Hub 4 Trade Hub 5
CON
End of
Trade Hub 6
CAR SPACE
A :82.55sqm A :57.77sqm A :57.77sqm A :57.77sqm A :58.85sqm trip facility
2.60x5.40
0
0 x 5 .4
ST
ANY NEW AND EXISTING FENCES TO BE FINISED WITH BRISTOL, TREACLE' EXTERIOR PAINT OR EQUIVALENT COLOUR. 100 2 .4 0 ACE
CAR
S P Motorbik A :111.22sqm
C
e Parking
.
LANDSCAPE AND /OR BUILDING CONTRACTORS ARE RESPONSIBLE FOR CIVIL AND HYDRAULIC COMPUTATIONS FOR PROVIDE 2.1MHIGH BLACK PVC COATED CHAIN 1-Cav
PA
LANDSCAPE BUILDING WORKS INCLUDING, BUT NOT LIMITED TO SURFACE AND SUB SURFACE DRAINAGE FOR ALL LANDSCAPEMESH FENCE, ALONG SOUTH/WESTERN
TH
0
AREAS. PRIOR TO COMMENCEMENT OF WORKS. BOUNDARY. 2 .4 0
x 5 .4
CE
SP A
CAR
NE
12427
DO NOT SCALE FROM PLAN CONTACTOR TO VERIFY ALL DIMENSIONS ON SITE PRIOR TO COMMENCING CONSTRUCTION.
WHILE CARE HAS BEEN TAKEN TO SELECT TREES WITH NON-INVASIVE TREE SPECIES WITH NON-INVASIVE ROOT SYSTEMS IT IS
55-Lln x 5 .4
0
RECOMMENDED THAT ROOT CONTROL BARRIERS BE INSTALLED FOR ANY TREES LOCATED WITHIN 2 METERS OF ANY
BUILDING LINES.
2 .4 0
CAR
S P ACE WS
A
RE
1-Cav
TREES AND SHRUBS SHALL BE HEALTHY NURSERY STOCK FREE FROM INSECTS, DISEASES AND WEEDS. THE SPECIFIED PLANT
PROPOSED CONCRETE DRIVEWAY &
HEIGHTS, AND POT SIZES ARE MINIMUMS. IF PLANT MATERIAL IS UNAVAILABE IN THESE SIZES, LARGER STOCK MUST BE EXISTING COUNCIL STORM
CAR PARKING
USED. PLANT SUBSTITUTION IS NT ACCEPTABLE. WATER DRAIN Lower Level
6000
2.60x5.40
12 . 4 1 1
CAR SPACE
THE CONTRACTOR IS TO SUPPLY AND INSTALL SEMI MATURE TREES WHICH MEET THE FOLLOWING CRITERIA:
9
D
10
- HAVE A MINIMUM PLANT HEIGHT TO SIZES AS INDICATE
WS
- HAVE A MINIMUM CALLIPER OF 50mm AT GROUND LEVEL.
- BE UNDAMAGED AND FREE FROM DISEASES AND INSECT PESTS 1-Cav
- NOT BE ROOT BOUND OR HAVE CIRCLING OR GIRDLING ROOTS BUT HAVE ROOTS GROWN TO THE EDGE OF THE
CONTAINER. Trade Hub 7
- SHOULD BEAR A SINGLE TRUNK, STRONG BRANCHING PATTERNS, AND FULL CANOPY. EXISTING UNITY WATER SEWER
A :44.24sqm
- SHOW HEALTHY, VIGOROUS GROWTH. 12998
PROPOSED CONCRETE
CROSSOVER
49.5
NOTE:
C A R 4 0 x 5 .4
0
Trade Hub 16 Trade Hub 17
C A R 4 0 x 5 .4
100
CAR SPACE
2.
EXISTING VEGETATION
SPA 0
2.
2.40x5.40
SPA 0
A :63.64sqm
45m
EXISTING TREES AND SHRUBS INDICATED FOR RETENTION ARE TO BE PROTECTION IN ACCORDANCE WITH AUSTRALIAN
CE
A :67.16sqm
CE
STANDARDS, REFER TO ARBORISTS REPORT AND/OR COUNCIL PERMIT CONDITIONS FOR TREE PROTECTION AND 1-Cav
MANAGEMENT, TREES SHOULD BE PROTECTED WITH PHYSICAL BARRIERS TO PREVENT ACCESS WITH NOMINATED TREE
6000
PROTECTION ZONES WHICH ARE TO BE MULCHED AND IRRIGATED DURING CONSTRUCTION. NO TREES TO BE REMOVED
(106
WITHOUT CLARIFICATION FROM OWNER OR LOCAL COUNCIL. ALL TREE PROCTECTION IN ACCORDANCE WITH RELEVANT
Trade Hub 15 WS Trade Hub 8
AUSTRALIAN STANDARDS.
A :75.45sqm
°08'3
8700 A :42.66sqm
GARDEN BEDS Trade Hub 14 WS
WS
CULIVATED EXISTING SOIL TO 200m. RE-USE SITE TOPSOIL IF SUITABLE OR IMPORTED GARDEN MIX TOPSOIL MINIMUM A :82.32sqm
0") D
EA
100mm OF TOPSOIL TO GARDEN BEDS, SPREAD 75mm LAYER OR 10mm PINE BARK MULCH. WS
METAL
IRRIGATION 1-Cav
LOW WATER USE DRIP SYSTEM WITH PROGRAMMABLE TIMERS CONNECTED TO RAINWATER STORAGE TANKS OR WATER WS
SE
MAINS, IRRIGATION MUST BE USED IN COMPLIANCE WITH CURRENT WATER RESTRICTIONS.
RAIN
DRAINAGE
ME
WS
TEMP. F
RE
REFER TO ENGINEERING PLANS FOR STORM WATER AND DRAINAGE PIT LOCATIONS.
SEW
AGE
SERVICES
NT
CONTRACTORS ARE TO DETERMINE THE LOCATION OF ALL UNDERGROUND AND OVERHEAD SERVICES PRIOR TO Trade Hub 9
ER
600
CONSTRUCTION. ANY SERVICES, PITS ETC ILLUSTRATED ON THIS PLAN ARE INDICITIVE ONLY AND ARE TO BE CHECKED WITH
SER
A :70.11sqm
0
1-Cav
SER
THE ENGINEERING PLANS.
NE
ik e
ENCING
6.282m
BUILDING STRUCTURES o t o rb
M k in g
Par
VICE
V IC
THE USE OF THIS PLAN AND PLANTING OF TREES, SHRUBS ETC AS SPECIFIED MAY REQUIRE THE PROVISIONS OF ROOT
CONTROL BARRIERS OR SPECIFICALLY ENGINEERED FOUNDATIONS OR SIMILAR METHOD OF CONTROLLING ROOT GROWTH
E
CAR SPACE
CAR SPACE
TO AVOID INTRUSION INTO ADJACENT AREAS OR BUILDING FOUNDATIONS. A QUALIFIED CONSULTANT SHOULD ADVISE ON
2.60x5.40
2.60x5.40
FOUNDATION DESIGN AND/OR BARRIERS (PHYSICAL OR CHEMICAL) AS APPROPRIATE.
OUT
SITE PREPARATION SCHEDULE
L IN E
ST
GENERAL
OF G
SITE PREPARATION TO BE CARRIED OUT IN ACCORDANCE WITH BEST HORTICULTURAL PRACTICEAND UNDER SUITABLE 1-Cav Trade Hub 10
ROU
CONDITIONS. DISTURBANCE TO INDIGENOUS SOIL STRUCTURE IS TO BE MINIMISED. THE USE OF MACHINERY THAT MAY A :46.20sqm
ND F
650
DAMAGE SOIL STRUCTURE OR PROFILE IS NOT ACCEPTABLE. WS
RE
LOO
3-Lhy
0
WEED CONTROL
Trade Hub 11 E
R
REMOVE AND DISPOSE OR ENVIRONMENTAL WEEDS OFF SITE PRIOR TO SUBGRADE PREPARATION, TOPSOILING AND
A :45.36sqm
VIC 1-Dtr
ER1-Mt
PLANTING WORKS. E S
WS
N AG
Trade Hub 12 D RAI
ET
ING
100
SUB-GRADE PREPARATION 1-Mt C
CON
A :45.36sqm
EN
0
SUB-GRADE TO ALL LAWN AND PLANTED AREAS IS TO BE CULTIVATED TO A MINIMUM DEPTH OF 150mm AND SHAPED TO 1-Cav N T F
E TAL
WS
Trade Hub 13 AY
EM
ACHIEVE DRAINAGE FALLS PRIOR TO TOPSOILING.
E W 1-Mt ME
C. P
SUBGRADE TO BE TESTED PRIOR TO PREPARATION AND CONDITIONING TO DETERMINE PH, SALINITY AND GYPSUM A :48.80sqm I V
DR n 10 E A S
CON
T E
RE de 1 i
REQUIREMENT, ANY GYPSUM REQUIRED IS TO BE DISTRIBUTED AT THE MANUFACTURERS RECOMMENDED RATE AND
HYD TER
C
ATH
O N G ra
BOO
CULTIVATED INTO THE SUB-GRADE AT A MINIMUM DEPTH OF 150mm.
C 1-Mt
CRE
SPREADING OF TOPSOIL 100
0
RAN
TOPSOIL IS TO BE SPREAD IN MAXIMUM 150mm LAYERS, LIGHTLY COMPACTED BY USE OF A 150-200kg ROLLER, OR BY W
TE
S
S
THOROUGHLY WALKING IN. CONTINUE PLACING TOPSOIL UNTIL IT ACCORDS WITH FINISHED KERB LEVELS OR TO WITHIN 1-Mt
1-Cav
DRI
75mm BELOW EDGING LEVELS TO ACCOMMODATE MULCH.
T
IMPORTED TOPSOIL
VEW
IMPORTED TOPSOIL FOR GARDENS IS TO BE MEDIUM TEXTURE GENERAL PURPOSE GARDEN SOIL, TO COMPLY WITH S.A.A. 1-Mt
ME
OR PROVIDE CONVEX MIRROR TO FACILITATE
2223-1978, AND AS FOLLOWS: DF
LO
AY
UN
SIGHTLINES AT INTERSECTIONS
TA
O
GR
- FREE FROM PERENNIAL WEEDS AND THEIR ROOTS, BULBS AND RHIZOMES
U TL
I NE
OF
1-Mt
L
- FREE FROM BUILDING RUBBLE AND ANY OTHER MATTER DELETERIOSU TO PLANT GROWTH
100
O
TE
- PH TO BE 6.0-7.0
0
1-Mt
MP
- TEXTURE TO BE LIGHT AND MEDIUM FRIABLE LOAM
1-Cav
ING
- FREE FROM SILT MATERIAL
.
C
FE
EN
SOIL IS TO BE LIGHTLY COMPACTED TO MIN. 300mm DEPTH TO GARDEN BEDS.