NOOSA COUNCIL 1
AMENDMENT SCHEDULE
APPROVED PLAN
05-01 ISS DATE DESCRIPTION BY
1 23/06/17 CONSULTANT ISSUE RF
MCU17/0073.01 11 DEC 2020
2 30/01/18 DA RFI RESPONSE BB
3 01/11/18 PRELIMINARY ISSUE JM
4 11/02/20 CONSULTANT ISSUE BB
5 03/03/20 ISSUE FOR QS PRICING BB
bca fa bca
6 01/07/20 VE CHANGES FOR CLIENT SIGN-OFF BB
1 1 7 18/08/20 DRAFT MINOR CHANGE DRAWINGS BB
8 15/09/20 MINOR CHANGE BB
fa rca BO
fa UN
guh
15.00° 15.00° guh DA
RY
1900
5 W18
slg 5
08-01 G.26 08-01
1250 1250
dp
2 2
dp
mrs mrs
1450 15.00° 15.00° 1450
dp
3 3
dp
Line of building below
fa fa
rca
2 guh guh 2
05-01 05-01
4 4
dp dp
2
05-02
bca fa bca
5 5
fa dp
guh 15.00° 15.00°
rca
1 mrs 1
ABBREVIATION LEGEND
05-02 05-02
ABBV DESCRIPTION
bca Barge capping
dp
6 6 dp downpipe, refer to hydraulic engineers
documents
7459 fa Fascia, timber. Refer to External finishes
schedule for paint colour. Re-paint all
fa fa existing fascias to match proposed.
guh gutter, half-round, colourbond, refer to
guh hydraulic engineers documents.
mrs mrs metal roof sheeting
dp rca Ridge capping
7 7
dp slg Skylight double glazed
mrs
slv sky light, velux, refer to fitout and finishes
15.00° 15.00° 15.00° schedule.
existing existing vpi vent pipe, refer to mechanical engineers
documents.
8 8
fa guh
9 9
guh
Provide new fascia, gutter, and
downpipes to west side of main roof. Make good existing Hall roof (grey tone) and carry out maintenance and
dp
repairs where necessary. Contractor to inspect roof and define scope and vpi
provisional sum budget for acceptance with tender submission.
rca
10 10
NOTE: Figured dimensions to be taken in preference to scaled.
Verify all dimensions on site before commencing work or
vpi making shop drawings. When printing from electronic files it is
the responsibility of the operator to ensure the required scale is
15.00°
achieved. Perspectives are for illustration purposes only. IF IN
mrs DOUBT, ASK.
bca
guh guh guh
fa
15.00° 15.00°
existing existing slv
11 2 rca 2 11
dp
05-03 05-03
existing roof below
15.00°
fa
Provide new barge board and mrs
capping to existing gable end. dp
fa slv This design is the property of the architect and may not be used, copied, or
15.00° reproduced wholly or in part, without the express permission of the
architect. Infringement in any way may result in legal action.
1220
mrs
PROJECT
vpi
fa EXISTING
BUILDING CHURCH ALTERATIONS
FOR
12 slv 12 GOOD SHEPHERD CHURCH
NOOSA
@
1 1
15.00°
1142
C:\KDA_Projects\160012_M11_brett.b.rvt
05-03 mrs 05-03 115 EUMUNDI ROAD, NOOSAVILLE,
guh
QLD 4566
PRELIMINARY
DRAWING TITLE
15/09/2020 11:17:07 AM
13 13 ROOF PLAN
1194
DATE SCALE @ A1 DRAWN
1
05-01 March 17 1 : 100 RF
DRAWING No.
fa dp guh
1:100 160012_ C - A - 02-04_8
0 1 2 3 4 5 10
2
A C 05-02 D E
B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plan MCU17-0073.01.pdfRelated documentApplication case desk ↗
About this file
- File size
- 11.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.