402. 103. Noise emission from mechanical equipment shall comply with the following requirements: Air-conditioning and Refrigeration * 7am to 10pm: Maximum background + 5dB(A) e¢ 10pm to 7am: Maximum background + 3dB(A) Pumps * 7am to 7pm: Maximum background + 5dB(A) ¢ 7pm to 10pm: Maximum background + 3dB(A) ¢ 10pm to 7am: No audible noise. Written certification from a suitably qualified person shall be submitted confirming that the noise levels from all mechanical equipment comply with the levels detailed above when measured at either the residential boundary or outside the most exposed part of an affected building, whichever is the closest to the equipment. The certification is required immediately after installation of the equipment and prior to any occupation of the building, and in a format approved by Council. This assessment must take into account noise from any other fixed equipment on the property e.g. swimming pool pump, heating/cooling equipment, etc that may increase the overall noise level emitted. Kitchen Exhaust 404. Any commercial kitchen exhaust points must be located and operated in accordance with AS1668.2 “The use of ventilation and air conditioning in buildings — Ventilation design for indoor air contaminant control”, Section 5 — Mechanical Ventilation — Exhaust Systems, 5.10 Air Discharges. Trade Waste 105. The drainage system from all business that are likely to discharge trade waste must comply with Council's Trade Waste Policy and Sunshine Water's guidelines for accepting trade waste into the sewer. All appropriate trade waste permit and/or agreements must be applied for and issued prior to the discharge of any trade waste to the sewer. THE FOLLOWING ADVICES ARE FOR INFORMATION PURPOSES ONLY AND DO NOT FORM CONDITIONS OF APPROVAL 1. The applicant is advised that development contributions and infrastructure charges applicable to this development approval have been based on the following Uses Class/ Uses and applicable quantities:- Existing Development Approved Development Existing Use Class / Existing Quantity Approved Use Class / Approved Quantity Use Use Detached House 1 , (Caretakers | Commercial Business | 4 99,,2 residence) Type 1 - Office Visitor 76 Retail Business Type 2 387m? Accommodation Type (consisting of 8 — Shop Saion 2 ; Caravan Park Cabins, 46 Powered | Entertainment & Dining Sites 22 Unpowered | Business Type 1 — | 306m” Sites) Food and Beverage Visitor Accommodation | 68 — Type 4 Conventional (Single Hostel Bed for tourist of overnight
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Judgement.pdf [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.