5.      Amend the roof plan to clearly illustrate the location of eave overhangs for the
        building.

6.      Demonstrate landscaping opportunities between the proposed swimming pool
        and the boundary. Currently, there is insufficient landscaping to buffer the
        building from adjacent uses.

7.      As the proposed development is listed as an inconsistent use (Specific Outcome
        33 – Eastern Beaches Locality Code), provide further justification of the planning
        need for the proposed development on the subject site.

8.      In your report, page 14, you suggest the Substation Kiosk noted on the proposed
        plans is private infrastructure associated with the adjoining Peregian Boardwalk
        development. However, the approved plans (MCU 05/1917 – Peregian
        Boardwalk development) do not illustrate the Substation Kiosk. Provide details of
        the purpose of the substation and possible access.

Land Development

9.      Provide a plan of the building and other structures indicating the exact location of
        the sewer on the site and demonstrate that the proposed structures comply with
        the setbacks to sewer required by Council's "Existing Services Code". If it is
        proposed to relocate the sewer please provide a plan of the alternative, as plans
        currently indicate a pool over the top of the existing sewer and buildings within
        the required setback.

10.     Provide a plan indicating the proposed access arrangement from David Low Way
        in more detail.

11.     Justify why more on site rainwater storage (3000 litres proposed) is not required
        given that the units are for rental accommodation and will require water usage,
        although to a lesser extent than a normal dwelling unit. Officers believe that the
        motel units are not exempt from Schedule 8 and require some rainwater reuse
        capacity.

12.     Provide evidence that the queuing distance to the visitor spaces complies with
        AS2890.1:2004 - Parking Facilities Part 1 Off-street Car Parking.

13.     Demonstrate compliance of motel guest car spaces with AS2890.1:2004 -
        Parking Facilities Part 1 Off-street Car Parking in regard to entering and exiting
        the spaces via turning templates on plan view for either side of the motel. Also
        demonstrate that the turn at the eastern end of the aisle can be made by
        including a plan with a vehicle turning template superimposed.

14.     Demonstrate that the spaces' operation for door opening will not be affected by
        the location of building columns (see Figure 5.2 AS2890.1:2004 - Parking
        Facilities Part 1Off-street Car Parking).

Environmental Health

15.     Please clarify the purpose of the area marked “In House Dining” &
        Entertainment”. Please provide information detailing whether or not meals will be
        prepared in the commercial kitchen.



     Award Winner - Australian Clean Beach
       Challenge 2004 Litter Prevention

Used in these records

About this file

File size
17 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Request for Further Information - 010.2006.00002552.001 [As Published].pdf · 17 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.