                                                                                                                                                                                                                    ROOFWATER DRAINAGE GENERAL NOTES:
                                                                                                                                                                                                                    ALL ROOFWATER DRAINAGE SYSTEMS MUST BE
                                                                                                                                                                                                                    CONNECTED TO A STORMWATER DRAINAGE
                                                                                                                                                                                                                    SYSTEM COMPLYING WITH BCA PART 3.1.2,
                                                                                                                                                                                                                    DRAINAGE OR AS/NZS3500.

                                                                                                                                                                                                                    THE ROOF DRAINAGE SYSTEM MUST BE PROVIDED
                                                                                                                                                                                                                    WITH AN OVERFLOW TO PREVENT THE BACKFLOW
                                                                                                                                                                                                                    OF WATER INTO THE BUILDING.

                                                                                                                                                                                                                    THE AREA SPECIFIC RAINFALL INTENSITY MUST BE
                                                                                                                                                                                                                    SELECTED FROM BCA TABLE 3.5.2.1 OR FROM
                                                                                                                                                                                                                    AS/NZS3500.

                                                                                                                                                                                                                    GUTTERS AND DOWNPIPES MUST BE SELECTED
                                                                                                                                                                                                                    FROM BCA TABLE 3.5.2.2 OR FROM AS/NZS3500.

                                                                                                                                                                                                                    EAVES GUTTERS MUST BE INSTALLED AT A FALL NOT
          GUTTER DETAIL                                                                                                                                                                                             LESS THAN 1 IN 500 WITH SUPPORT BRACKETS AT
                                                                                                                                                                                                                    1.2m MAXIMUM CENTRES.
          NTS
                                                                                                                                                                                                                    BOX GUTTERS MUST BE INSTALLED AT A FALL NOT
                                                                                                                   dp                                            dp                                                 LESS THAN 1 IN 100, IN ACCORDANCE WITH
                                                                                                                                                                                                                    AS/NZS3500.3.

                          dp                                                                                                                                                                                        THE WIDTH OF VALLEY GUTTERS SHALL BE IN
                                                                                                                                                                                                                    ACCORDANCE WITH AS/NZS3500.3 AND BCA PART
                                                                                                                                                                                                                    3.5.2.

                                                                                                                                                                                                                    REFER TO ROOF SHEETING MANUFACTURERS
                                                                                                                                                                21°                                                 SPECIFICATIONS FOR LIMITATIONS ON SHEET
                                                                                                                                                                                                                    OVERHANGS INTO VALLEY GUTTERS.
                                                                                                                                 Area




                                                                                                             21°
                                                                             Area                                                                                                                                   THE MAXIMUM ROOF CATCHMENT AREA FOR

                                                                        35 m²                                                    40 m²                   Area                                                       VALLEY GUTTERS IS 20m2.

                                                                                                                                                                                                                    VALLEY GUTTERS ON ROOFS PITCHED LESS THAN
                                                                                                                                                         30 m²                                                      12.5° MUST BE DESIGNED AS BOX GUTTERS.

                                                                                                                                                                                                                    DOWNPIPES MUST SERVE NOT MORE THAN 12
                                                                                                                                                                                                                    METRES OF GUTTER LENGTH FOR EACH DOWNPIPE
                                            21°                                                                                                                                                                     WHICH MUST BE LOCATED AS CLOSE AS POSSIBLE
                                                                               (6 DOWNPIPES REQUIRED @40sqm/DP)                                                                                                     TO VALLEY GUTTERS.
                                                                                    6 DOWNPIPES PROVIDED




                                                                                                                                                                      21°
                                                                                                                                                                                                                    EAVES GUTTERS MUST BE PROVIDED WITH AN
                                           Area                                       TOTAL ROOF CATCHMENT                                                                                                          OVERFLOW SYSTEM WHERE DOWNPIPES ARE
                                                                                            AREA 222 m²                                                                                                             LOCATED MORE THAN 1.2 METRES FROM A
                                          38 m²                                                                                                                                                                     VALLEY GUTTER.

                                                                                                                                                                                                                    TABLE 3.5.2.1 RAINFALL DURATION INTENSITY
                                                                                                                                                                                                                    5 MINUTE DURATION RAINFALL INTENSITY
                                                                                                                                                                                                                    NOOSA HEADS - 20YEARS     258mm/h
                                                                                                                                                                                                                                - 100YEARS 331mm/h

                                                                                                                                                                                                                    TABLE 3.5.2.2 GUTTER & DOWNPIPE SELECTION
                                                                                                             21°
                                                                        Area                                                                      Area




                                                                                                                                                                      21°
                                                                                                                                                                                                                    FROM TABLE A & B
                                                                       40 m²                                                                     40 m²                                                              40sqm - A - MEDIUM RECTANGULAR GUTTER or
                                                                                                                                                                                                                            D - 125mm D GUTTER

                                                                                                                                                                                                                    FROM TABLE C
                          dp
                                                                                                                                                                                                                    90mm DIAMETER DOWNPIPE

                                                                                                    dp                                                                      dp                                      TABLE 3.5.2.3 OVERFLOW VOLUME
                                                                                                                                                                                                                    FROM TABLE A

                                                                                                                                                                                                                    350mm/h    12.0m GUTTER [email protected] (L/s/m) = 14.4L/s

                                                                                                                                                                                                                    FROM TABLE B

                                                                                                                                                                                                                    350mm/h - 40sqm = 3.9(L/s)

                                                                                                                                                                                                                    USE CONTROLLED BACK GAP (SEE DETAIL)
ROOF CATCHMENT PLAN                                                                                                                                                                                                          = 1.25 L/s/m x 12.0m = 15.0L/s
1 : 100

                               THESE DRAWINGS AND DESIGN ARE    ISSUE DATE     DRWN CHKD COMMENTS                                                                                                                 DATE
                               COPYRIGHT AND WILL NOT BE USED
                                                                                                                                    PROJECT                                  JOB SPECIFICATION BY BUILDER TAKES
                               OR REPRODUCED BY ANY MEANS,
                                                                  *   17/10/2018 AK   RW PRELIMINARY PLANS
                                                                                                                                    PROPOSED RESIDENCE                       PRECEDENCE OVER THESE PLANS                        ROOF CATCHMENT PLAN
                               WHOLLY OR PARTLY WITHOUT PRIOR    A    22/10/2018 AK   RW RELOCATED, WIDTH REDUCED, EAVES ADDED
                                                                                                                                                                                 CLIENT               SALES CHRIS McNEIL        PROJECT STATUS
                               WRITTEN PERMISSION FROM -                                                                            CUSTOM
                                                                  B   25/10/2018 AK   RW GENERAL AMENDMENTS
                               GJ GARDNER HOMES                                                                                                                                                                                             CONSTRUCTION DRAWINGS
                                                                 C    12/11/2018 AK   RW GENERAL AMENDMENTS
                                                                                                                                    CLIENT                                       LOCATION                                       SCALE       SHEET SIZE   CLASS      WIND    ISSUE
                      DO NOT SCALE FROM THIS DRAWING D                13/11/2018 AK   RW DRAFT CONSTRUCTION DRAWINGS
                               VERIFY ALL DIMENSIONS PRIOR TO     E   17/01/2019 AK   RW AMENDED CONSTRUCTION DRAWINGS              ERHARTER, Robert                             LOT 6 ON RP82318                               INDICATED        A3      1a                    E
                               COMMENCEMENT OF ANY SITE WORKS
                                                                                                                                                                                 10 OPAL LANE                                   DRAWING FILE NUMBER        PAGE
                               AND REFER ANY DISCREPANCIES TO
                               BESPOKE BUILDING DESIGN                                                                                                                           COOROY, QLD                                    GJGSCN190173                               6
Log in to download the original file

proposal plans for submission.pdf · 6.6 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.