Council archive · source document
Approved Plan 51988.63.02
Plans and drawings: the text below has words only, no drawings.
-
NOOSA COUNCIL
APPROVED PLAN
51988.63.02 18 AUG 2016
E
D
C
B
PROPOSED ADDITIONS
PROPOSED EXISTING
ADDITIONS BUILDING
23500
A
12 11 10 9 8 7 6 5 4 3 2 1
30250 PROPOSED ADDITIONS 29100 EXISTING BUILDING
AREA SCHEDULE
SITE PLAN
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
1 1 : 500 NORTH
EXISTING BUILDING
GROUND FLOOR STAGE 1
848.72
523.27
GROUND FLOOR STAGE 2 192.59
MEZZANINE STAGE 2 198.55
Grand total 1763.13
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 SITE PLAN
A3
2 17-3-16 ISSUED FOR FUNDING
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
A 27-4-16 ISSUED FOR APPROVAL 3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 27-Apr-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 10:22:22 PM 1 : 500
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK101 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 6 pages
Page 2
-
NOOSA COUNCIL
APPROVED PLAN
51988.63.02 18 AUG 2016
33085
10
E
ENTRY
STAGE 2 STAGE 1 OFFICE CHANGE1 CHANGE2 STAFF MALE FEM REC
5600
DIS
BLOCKWORK
EXTERNAL WALLS
D
C
UP
B
SCREEN WALL TO CLOSE OFF RECEPTION
CORRIDOR
KINDEGYM STORE
CONCRETE FLOOR SLAB TO
MATCH EXISTING FLOOR LEVEL -
WITH PIT RECESSES FOR
EQUIPMENT TO ENG'S DETAILS
23500 PROPOSED ADDITIONS
KINDEGYM PROPOSED GYM EXISTING GYM
29900
ROOM ADDITIONS BUILDING
STAGE 1 523sqm 850sqm
FOOD PREP
STEEL PORTAL FRAME TO ENG'S DETAILS
STEEL PORTAL FRAME TO ENG'S DETAILS
STEEL PORTAL FRAME TO ENG'S DETAILS
STEEL PORTAL FRAME TO ENG'S DETAILS
STEEL PORTAL FRAME TO ENG'S DETAILS
R
OVE
INE
ZAN
MEZ
STAGE 2
193sqm
GLASS WALL AND
DOORS TO CLOSE OFF STORE
KINDEGYM AREA FROM
MAIN GYMNASIUM
UP NORTH
A
KINDEGYM
ENTRY
12 11 10 9 8 7 6 5 4 3 2 1
STAGE 2 STAGE 1 AREA SCHEDULE
30250 PROPOSED ADDITIONS 29100 EXISTING BUILDING
EXISTING BUILDING 848.72
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
GROUND FLOOR STAGE 1 523.27
GROUND FLOOR PLAN GROUND FLOOR STAGE 2 192.59
1 1 : 200
MEZZANINE STAGE 2 198.55
Grand total 1763.13
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 GROUND FLOOR PLAN
A3
2 17-3-16 ISSUED FOR FUNDING
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
A 27-4-16 ISSUED FOR APPROVAL 3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 27-Apr-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 10:22:25 PM 1 : 200
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK102 A
Page 3
-
NOOSA COUNCIL
APPROVED PLAN
51988.63.02 18 AUG 2016
E
STAGE 2 STAGE 1
D
C
UP
B
PROPOSED VOID TO NEW VOID TO EXISTING
MEZZANINE GYM BELOW GYM BELOW
LEVEL
STAGE 2
198sqm
UP NORTH
A
12 11 10 9 8 7 6 5 4 3 2 1
STAGE 2 STAGE 1
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
MEZZANINE FLOOR PLAN
1 1 : 200
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 MEZZANINE FLOOR PLAN
A3
2 17-3-16 ISSUED FOR FUNDING
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
A 27-4-16 ISSUED FOR APPROVAL 3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 27-Apr-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 10:22:26 PM 1 : 200
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK104 A
Page 4
-
NOOSA COUNCIL
APPROVED PLAN
51988.63.02 18 AUG 2016
33085
E
5600
STAGE 2 STAGE 1
NEW ZINCALUME BOX GUTTER
D
C
B
23500 PROPOSED ADDITIONS
2.54°
2.54°
29900
PROPOSED EXISTING
ADDITIONS BUILDING
NEW COLORBIND METAL ROOF
TO MATCH EXISTING ROOF
PROFILE AND ROOF SLOPE
2.54°
2.54°
EXTEND EXISTING ZINCALUME BOX
GUTTER TO NEW ROOF AREA
A NORTH
12 11 10 9 8 7 6 5 4 3 2 1
30250 PROPOSED ADDITIONS 29100 EXISTING BUILDING
STAGE 2 STAGE 1
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
ROOF PLAN
1 1 : 200
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 ROOF PLAN
A3
2 17-3-16 ISSUED FOR FUNDING
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
A 27-4-16 ISSUED FOR APPROVAL 3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 27-Apr-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 10:22:26 PM 1 : 200
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK105 A
Page 5
30250 PROPOSED ADDITIONS 29100 EXISTING BUILDING -
NOOSA COUNCIL
STAGE 2 STAGE 1 APPROVED PLAN
12 11 10 9 8 7 6 5 4 3 2 1
COLORBOND METAL
51988.63.02 18 AUG 2016
WALL SHEETING TO
MATCH EXISTING 7500
RL 17.500
5135 4500
RL 15.135 3900
7500
3000 RL 13.900
RL 13.000
3000
GROUND GROUND
RL 10.000 METAL LOUVRES TO BLOCKWORK TO RL 10.000
MATCH EXISTING MATCH EXISTING
South Elevation
1 1 : 200 29100 EXISTING BUILDING 30250 PROPOSED ADDITIONS
STAGE 1 STAGE 2
1 2 3 4 5 6 7 8 9 10 11 12
COLORBOND METAL
WALL SHEETING TO
7500 MATCH EXISTING
RL 17.500
5135
4500
1235
3900 RL 15.135
7500
RL 13.900 3000
RL 13.000
3000
GROUND GROUND
RL 10.000 METAL LOUVRES TO BLOCKWORK TO
RL 10.000
MATCH EXISTING MATCH EXISTING
North Elevation
4 1 : 200
D D
A B C E E C B COLORBOND METAL A
WALL SHEETING TO
MATCH EXISTING 7500
RL 17.500
5135
4500
RL 15.135 3900
7500
3000 RL 13.900
RL 13.000
3000
GROUND GROUND
RL 10.000 METAL LOUVRES TO BLOCKWORK TO RL 10.000
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
MATCH EXISTING MATCH EXISTING
East Elevation West Elevation
3 1 : 200
2 1 : 200
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 ELEVATIONS
A3
2 17-3-16 ISSUED FOR FUNDING
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
A 27-4-16 ISSUED FOR APPROVAL 3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 27-Apr-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 10:22:29 PM 1 : 200
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK201 A
Page 6
30250 PROPOSED ADDITIONS 29100 EXISTING BUILDING
STAGE 2 STAGE 1
12 11 10 9 8 7 6 5 4 3 2 1
2750 11000 5500 5500 5500
NEW ROOF TO MATCH EXISTING
7500
RL 17.500
GLASS
5135
4500 BALUSTRADE
MEZZ FLOOR RL 15.135
STEEL PORTAL 3900
ROOF FRAMES TO
3000 ENG'S DETAILS RL 13.900
RL 13.000
TIMBER FRAMED
NEW GYM
3000
KINDEGYM MEZZ FLOOR TO EXISTING GYM
ENG'S DETAILS
GROUND
RL 10.000
R.CONC FLOOR SLAB
TO ENG'S DETAILS
SECTION A
A 1 : 200 29100 EXISTING BUILDING 30250 PROPOSED ADDITIONS
STAGE 1 STAGE 2
1 2 3 4 5 6 7 8 9 10 11 12
NEW ROOF TO MATCH EXISTING
7500
RL 17.500
5135
4500
GLASS
STEEL PORTAL BALUSTRADE MEZZ FLOOR RL 15.135
3900 ROOF FRAMES TO
7500
RL 13.900 ENG'S DETAILS 3000
TIMBER FRAMED RL 13.000
NEW GYM
3000
EXISTING GYM MEZZ FLOOR TO KINDEGYM
ENG'S DETAILS
GROUND GROUND
RL 10.000 RL 10.000
R.CONC FLOOR SLAB
TO ENG'S DETAILS
D
SECTION B
B 1 : 200
NEW ROOF TO MATCH EXISTING A B C
22000 1500
7500
6500 RL 17.500
6000
RL 16.500
RL 16.000 GLASS
4500
STEEL PORTAL ROOF FRAMES BALUSTRADE
TO ENG'S DETAILS
7500
6500
3000
RL 13.000
3000
NEW GYM
GROUND GROUND
R.CONC FLOOR SLAB RL 10.000 RL 10.000
-
TO ENG'S DETAILS
NOOSA COUNCIL
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
APPROVED PLAN
SECTION C
51988.63.02 18 AUG 2016 C 1 : 200
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 SECTIONS
A3
2 17-3-16 ISSUED FOR FUNDING
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
A 27-4-16 ISSUED FOR APPROVAL 3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 27-Apr-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 10:22:30 PM 1 : 200
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK203 A
Page 7
PROPOSED ADDITIONS FROM NORTH-WEST
3
VIEW 1
1
PROPOSED ADDITIONS FROM SOUTH-WEST
4
-
NOOSA COUNCIL
E:\Dropbox\Dropbox Projects\1127 Noosa Gymnastics Club\1127 Noosa Gymnastics v2.rvt
APPROVED PLAN
51988.63.02 18 AUG 2016 VIEW 2
2
REV DATE DESCRIPTION SPECIFICATION NOTES DRAWING TITLE
1 09-02-16 ISSUED FOR DISCUSSION 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
READINGS
PROPOSED ADDITIONS TO TEL: (07) 5455 3651 VIEWS
A3
2 17-3-16 ISSUED FOR FUNDING
NOOSA BICENTENNIAL HALL
2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
COMMENCING FABRICATION [email protected]
A 27-4-16 ISSUED FOR APPROVAL 3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, WWW.SOULSPACE.COM.AU
DRAWN PROJECT No PLOT DATE SCALE
RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF BICENTENNIAL DRIVE, SUNRISE BEACH 27-Apr-16
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
Paul Hindes 1127 10:22:32 PM
QBSA Lic 1160074 ‐ ABN 81600841459
5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF DRAWING No REVISION
CONSTRUCTION
23 PALUMA ST SUNRISE BEACH QLD 4567
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR.
FOR NOOSA GYMNASTICS CLUB Exclusive Residential and Commercial Designs by Paul Hindes SK601 A
Used in these records