Bushfire Hazard Assessment & Management Plan v2                                           NCES REF: J001445
434 Lake Cooroibah Rd Lake Cooroibah, QLD


The assigned sub unit slopes are referenced on Plan BF02.
A FFDI of 47 has been adopted for the site consistent with the assignment by QFES.
The Flamesol output results are attached as Appendix 3 and summarised in Table 1.
                                     Table 1 Sub Unit Flamesol Results

   Sub Units                          SU1a (VHC 9.1, 100m   SU1b (VHC 9.1, 60m   SU2 (VHC 22.1, 100m
                                      flame width)          flame width)         flame width)
                                      1 deg                 1 deg                1 deg

   Flame Length (m)                   11.15                 11.15                12.59

   Fireline Intensity (kW/m)          15,866                15,866               20,748
                                      (Medium)              (Medium)             (High)

   Rate of Spread (km/hr)             1.26                  1.26                 1.41

   <29kW/m² RHF (m)                   12.4                  12.3                 14

Table 1 demonstrates Sub unit 2; paperbark open forest, represents slightly more severe bushfire
behaviour (High Potential Bushfire Intensity) than Sub unit 1a and 1b; eucalypt open forest (Medium
Potential Bushfire Intensity), which effectively exhibit similar bushfire behaviour.
The Flamesol results are reflected on Plan BF02 which demonstrates the entire site is captured in a
Low Potential Bushfire Intensity class.

4.4    Local Hazard Map
Plan BF03 – Local Hazard Map identifies the Potential Bushfire Intensity classes across the site
shown on Plan BF02 and includes a 100m wide Potential Impact Buffer.
The western and centre portions of proposed Lot 7 are captured in a Potential Impact Buffer whilst
the east of the Lot is captured in a Low hazard area. The proposed Lot 7 building envelope is located
in the cleared area in the north-west corner of the lot. On this basis, the building area is located in
the outer limits of the Potential Impact Buffer.
The Local Hazard Map presented in Plan BF03 is to supersede the SPP broadscale mapping
attributed to the site and should be used to guide the formulation of appropriate site-based bushfire
management measures for the proposal.




© 2026                                                15

Used in these records

About this file

File size
7.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Bushfire Hazard Assessment Management Plan v2 - 434 Lake Cooroibah Rd Lake Cooroibah v1.pdf · 7.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.