Bushfire Hazard Assessment Management Plan v2 - 434 Lake Cooroibah Rd Lake Cooroibah v1 · RAL26/0015

of 44

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
Bushfire Hazard Assessment & Management Plan v2                                                                                                                                                               NCES REF: J001445
434 Lake Cooroibah Rd Lake Cooroibah, QLD




Table 2 – Table 8.2.3.3 Bushfire Hazard Areas – Part 8 Overlay Code Noosa Plan 2020


 PERFORMANCE OUTCOMES                                            ACCEPTABLE OUTCOMES                                                       PROPOSED SOLUTION

 Safety of people and property

 PO1                                            AO1.1                                                                                      This Bushfire Hazard Assessment and Management Plan has been prepared to
 Development maintains the safety of people and Development which will materially increase the number of people                            maintain the safety of people and property from the adverse impacts of bushfire.
 property from the adverse impacts of bushfire. living or congregating on premises, including reconfiguring a lot, is not
                                                                                                                                           AO1.1 – No increase in the number of people living or congregating on premises
                                                located within a medium or high bushfire hazard area.
                                                                                                                                           is proposed within a confirmed medium or high bushfire hazard area.
                                                                 AO1.2
                                                                 Development maximises setbacks from hazardous vegetation to               AO1.2 –The extent of separation proposed in conjunction with the mitigating
                                                                 achieve an acceptable risk.                                               measures referenced within this report generates an acceptable risk.

                                                                 Editor’s Note —PSP8 Natural Hazards provides guidance for
                                                                 assessing bushfire hazard risk and preparing a bushfire hazard
                                                                 management plan.


 Impact on Ecologically Important Areas

 PO2                                                  No acceptable outcome provided                                                       No new clearing is deemed necessary to enact bushfire mitigation measures on
 Bushfire mitigation measures do not adversely impact                                                                                      the site.
 on:

 a) biodiversity values, connectivity and ecosystem
 functioning; and
 b) the long term physical integrity of waterways, wetland
 and areas of native vegetation.

 Water Supply for Fire Fighting Purposes

 PO3                                                        AO3.1                                                                          AO3.1 – Lot 7 will not be connected to the reticulated water supply. The new
 Development provides an adequate water supply for Premises are connected to the reticulated water supply.                                 water supply to Lot 7 should therefore satisfy Assessment Benchmark 4 of the
 firefighting purpose which is reliable, safely located and                                                                                SPP Bushfire 2019, which references the QFES 2019 Bushfire Resilient
 freely accessible.                                         Editor's note—For reconfiguring a lot, water supply needs to provide           Communities. Provision of 10,000 litres supply located within 10 metres of each
                                                            for a minimum flow and pressure of 10 litres a second at 200kPa at all         residential building on the lot is required.
                                                            times for firefighting purposes.

                                                                 OR

                                                                 AO3.2
                                                                 Where there is no available reticulated water supply, the premises
                                                                 has:

                                                                 a) an accessible dam, swimming pool or water tank available for
                                                                 firefighting purposes with an onsite water volume of not less than
                                                                 5,000 litres; and
                                                                 b) a water supply outlet pipe 50 millimetres in diameter fitted with a
                                                                 standard fire brigade fitting connected to the water supply (other than
                                                                 where the water supply is in a swimming pool or dam).




© 2026                                                                                                           28

Used in these records

About this file

File size
7.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Bushfire Hazard Assessment Management Plan v2 - 434 Lake Cooroibah Rd Lake Cooroibah v1.pdf · 7.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.