Architecturals
Attached to the e-mail app for exemption certificate - Agricultural Land overlay - 97 Cooks Rd Tinbeerwah L.T.msg.
FRAMING SCHEDULE WALLS — LOAD BEARING 90 x 35 studs at 450 centres not notched 2/90 x 35 top plates 90 x 45 bottom plate Maximum rod tiedown spacing 1200 Solid bridging or slab under load bearing bottom plates 90 x 35 nogging at 1300 maximum centres WALLS —- NON LOAD BEARING 70 x 35 studs at 450 centres, may be notched for bracing 70 x 35 top and bottom plates and nogging at 1300 max. centres where cavity sliding door units are fitted into non—load walls, framing to be 90mm All load bearing framing to be MGP12 seasoned softwood Lintels E13LVL unless noted Non loadbearing framing to be MGP10 seasoned softwood All timber framing to be in accordance with AS 1684.3-1999 for W41 non- cyclonic ( N3 ) exposure WINDOW SCHEDULE SOUTH EAST ELEVATION balustrade to comply with BCA clause 3. 9. 2. 3 WINDOW SIZE TYPE COMMENT HEAD SIZE JAMB STUDS Wi 2400x2400 Sliding door 2-240x45 E13LVL|3/90x35 MGP12 W 2 1500x2100 Sliding OXXO 240x45 EISLVL |2/90x35 MGP12 W3 | 2400x2700 | — Sliding OXX door |2—240x45 E13LVL|3/90x35 MGP12 w 4 | 2400x2700 | _ Sliding XX0 door |2—240x45 E13LVL|3/90x35 MGP12 W5 900x1200 Sliding = 130x45 E13LVL_ | 2/90x35 MGP12 W 6 900x600 Sliding - 90x45 E13LVL_ | 2/90x35 MGP12 Ww7 | 2100x1200 Sliding patio 150x45 E13LVL_ | 2/90x35 MGP12 sheet metal roofing on pressed metal battens at 900 centres Prefabricated engineer designed roof trusses by specialist installed at 900 sheet metal roofing on pressed metal W8 1500x2100 Sliding OXXO 170x45 E13LVL_ | 2/90x35 MGP12 centres to manufacturers specification battens at 900 centres Ww9 1500x2100 Sliding OXXO 170x45 E13LVL_ | 2/90x35 MGP12 240x45 E13LVL rafters at 900 ctrs W10 | 1500x2100 Sliding OXXO —_[2-240x45 ELSLVL| 2/90x35 MGP12 13° pitch Wil 1500x2100 Sliding OXXO 240x45 E13LVL_ | 2/90x35 MGP12 W 12 1500x2100 Sliding OXX0 240x45 E13LVL_ | 2/90x35 MGP12 W 13 2100x900 d/hung = 150x45 E13LVL_ | 2/90x35 MGP12 SS w14 | 450x1500 | adj gl Is = 130x45 ESLVL_| 2/90x35 MGP12 5 W 15 1500x1800 Sliding - 150x45 E13LVL | 2/90x35 MGP12 a 3S W 16 2100x900 d/hung - 130x45 E13LVL_ | 2/90x35 MGP12 8 W 17 2100x900 d/hung = 130x45 E13LVL_ | 2/90x35 MGP12 wi CONFIRM ALL HEAD SIZES WITH TRUSS MANUFACTURER FOR GIRDER LOADS = ~==~~~------- WHERE FRAME IS FACTORY PRE-FABRICATED ALL TIMBER SIZES TO BE tut THT a rity IN ACCORDANCE WITH MANUFACTURERS DESIGN AND CERTIFICATION an L¥s 1 LINING SCHEDULE WALLS 10mm plasterboard generally WR plasterboard to walls of bathrooms and laundry 6mm Villaboard to walls of showers SECTION CEILINGS 10mm plasterboard throughout on 50 x 38 pine battens at 450 centres 4.5 Versilux to all soffits on 50 x 38 Pine battens at 450 centres. s.L. R Trevor Roper QBCC licence no 3996 & % P ° PO BOX 852 CHILDERS QLD 4660 T:07 41263110 M:0412 786 3350 Noe » E: [email protected] RESIDENCE AT LOT 2 , 97 COOKS ROAD TINBEERWAH “| FOR D. ROSEBY AND A. COVEY Ge S Some = DRAWING REFERENCE 20—556-—5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.