Original source · versioned page text
Architecturals
Attached to the e-mail app for exemption certificate - Agricultural Land overlay - 97 Cooks Rd Tinbeerwah L.T.msg.
Sheet metal roofing to manufacturers spec’n pressed metal at 900 ctrs battens fixed to rafters / trusses to mfrs spec’n / 30 x 0.8 looped strap 4/2.8 nails each end TERMITE RISK MANAGEMENT Termite control to be in accordance with AS 3660.1 and BCA clause 3. 1. 3. Monolithic concrete slab laid in accordance with AS 2870.1 with 75mm exposed vertical concrete edge for visual termite control. rafters to top plate with approved looped strap metal rhs posts set in concrete pads with both prefabricated roof trusses ~ to mfrs spec’n ends sealed against termite ingress to give visual 900 centres \ termite control I RS . . Any untreated timber posts, stairs and the like shall be set a fix rafters to fascia beam 75 minimum clear of ground for visual termite control 10mm plasterboard to ceiling with approved joist hangers on pressed metal battens at | to mfrs specn Any active nest containing economically significant termites 450 centres \ 4 gutter within the property boundaries up to a distance of 50000 | ) from the proposed building shall be eliminated prior to 10mm plasterboard wall lining— | 4.5 Versilux soffits construction. All timber offcuts, building debris and other P 9 on metal battens at 450 ctrs materials such as cardboard and paper containing cellulose AN : shall be removed from the site. 12mm anchor rods at 1200 maximum eee post with centres and where indicated for sheet —_ / os Two approved notices shall be affixed to the dwelling as bracing walls * required advising owners of the method of termite risk | management used, and their ongoing responsibility for the SN maintenance of the systems 1 1 joists to trimmers with \ \ OL, approved Pryda joist \ \ fie hangers oe . a PP . se bearer to post with joists to trimmers with +--+ 2/M12 bolt approved Pryda joist | ton at he a aA? /MI2 bolts angers to bearer . . —"I __ set timber posts 75 min clear of ~ —_ 5 finished ground for visual | ~~ LI termite control Pi] Foil] i i tt fEX | 50 x 8 galv U bracket 2/M12 bolt to base poyotot i; \ of timber post and set 150 min into 350 i ym ie foe ote aime | || Sqare So sp conte pot Bea | aye concrete pad. NOTE footing is minimum ! H \ hy through bracket and carry down to within . . . I \ required fr reuown and may be Increased | | ! \ NOTE footing is minimum required for tie-down ¥ Son test Engineer | EZ==53 | and may be increased by soil test engineer Lo | got Ro Trevor Roper QBCC licence no 3996 y ©, PO BOX 852 CHILDERS QLD 4660 Y - . . RESIDENCE AT LOT 2 , 97 COOKS ROAD TINBEERWAH ): T:07 41263110 M:0412 786 350 = E: [email protected] FOR D. ROSEBY AND A. COVEY ae Ss DRAWING REFERENCE 20—556-8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.