Council archive · source document
Approved Plans MCU13/0171
Plans and drawings: the text below has words only, no drawings.
SP108094
2
EXISTING BRICKWORKS
DRAIN
COMPLEX PROPOSED DEVELOPMENT
APPLICATION WITHIN
DASHED AREA ONLY
rt
ve
ul
C
load bay 1
EXISTING DRAIN
EXISTING BUILDING
DRAIN
EXISTING
CROSS-OVER
e
6,
iv
00
r
0
D
load bay 2
ld
a
n
o
Cre d
ek c
Lin a
e M
ke
La
Ea
se
EXISTING ABOVE
m
GROUND FUEL STORE
en
EXISTING SUNSHINE COAST REGIONAL COUNCIL
t
CROSS-OVER
APPROVED
EXISTING
MCU 13/0171 1 NOV 13
SITE OFFICE BUILDING
DRAWINGS SCHEDULE :
COVER SHEET
DA-01 SITE PLAN 1:1000
DA-02 SITE PLAN 1:500
97.91 DA-03 GROUND FLOOR PLAN 1:200
DA-04 MEZANINE FLOOR PLAN 1:200
DA-05 ELEVATIONS 1:100
DA-06 ELEVATIONS 1:100
Neighbouring DA-07 SECTION 1:100
House
0 5m 50m 100m
WIMMERS FACTORY 06 September 2013
SCALE 1 : 1000 @ A1
271 Lake Macdonald dr.
ROBINSON
A RC HIT ECT S
Lake Macdonald PAGE No. DA-01 Copyright of Robinson Architects 2013.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 5 pages
Page 2
PROPOSED 44 CAR-PARKING EXISTING OVER FLOW CARPARKING
SPACES ON EXISTING AREA ON SEMI- HARDSTAND SURFACE
HARDSTAND SURFACE SHOWN HATCHED
BUS PARKING BAYS
PROPOSED FENCE
DRAIN
PROJECT DESCRIPTION
LOT 2 ON SP 108094
LOCAL AUTHORITY :
TRUCK TURN AROUND SUNSHINE COAST REGIONAL COUNCIL
TOTAL ALLOTMENT AREA : 44, 950 m²
rt
ve
ul
C
PROPOSED REVISED FLOOR AREAS :
load bay 1
EXISTING GROUND FLOOR : 5,238 m²
CULVERT MEZANINE : 322 m²
SITE COVER : 13 %
TOTAL GFA : 5560 m²
PROPOSED
WAREHOUSING AREA 64 SPACES CARPARKS PROVIDED
EXISTING BUILDING EXISTING DRAIN
DRAIN
EXISTING DRYING RM
(NEW COOL ROOM) EXISTING DOWN PIPES
6M LANDSAPING BUFFER
PROPOSED
MANUFACTURING AREA
PROPOSED
6,
00
PROPOSED TOUR BUS
0
VIEWING PLATFORM SET-DOWN
& PICK-UP
PROPOSED EXISTING CROSS-OVER
OFFICES & STORAGE RETAINED AS EMERGENCY
load bay 2
AT MEZZANINE LEVEL OR SECONDARY ACCESS
PROPOSED
ADMIN & AMENITIES PROPOSED
AT GROUND LEVEL LIGHT-WELL
PROPOSED
RECEPTION, MUSEUM,
e
SALES & FUNCTION AREA
r iv
D
EXISTING ld
16
a
,4
CHIMNEY STACK ENTRY
90
n
RETAINED o
d
c
PROPOSED FENCE a
M
ke
EXISTING La
ABOVE-GROUND
FUEL STORE PROPOSED FH EXISTING DRAIN
VISITOR PARKING
Ea
PRIMARY ENTRY
SUNSHINE COAST REGIONAL COUNCIL
20 SPACES
se
CROSS-OVER TO AS 2890.2
m
en
APPROVED
t
SINGLE STOREY
BRICK BUILDING MCU 13/0171 1 NOV 13
PP
(TO BE DEMOLISHED)
0 5m 25m
WIMMERS FACTORY 06 September 2013
SCALE 1 : 500 @ A1
271 Lake Macdonald dr.
ROBINSON
A RC HIT ECT S
Lake Macdonald PAGE No. DA-02 Copyright of Robinson Architects 2013.
Page 3
SUNSHINE COAST REGIONAL COUNCIL
APPROVED
MCU 13/0171 1 NOV 13
A Line interior of Museum
Gate & Fence area with brick B
Concrete tilt panel fire rated wall Fence
2,600
1,100
8,541
Existing Drying Rm
Reconfigured as Cool Rm
9,800
Museum
Steel Portal
Entry Trellis 206 m2
Workers
Lunch rm
OUT
Roller Door
Public Toilets
6,825
20,982
11 M
DA
up
1 OUT
M
1 Warehousing
7,453
Entry up
Foyer /
Lockers
Meeting Line of Mezanine above
Reception
Staff Toilets/
45,638
F Change
Fridge Display
Sales staff
Tea Rm
Roller Door
7,453
Informal
Lunch rm
Storage TRUCKS UNLOADING
Office
C Function / C
Factory
Display Rm Manager Roller
Door
Manufacturing
Office 1,000 m2
Manager Dispatch
15,366
Restored
Void
Ramp Up
Historic
Delivery
Truck
Scissor Lift Door Roller Door Roller Door Roller Door Roller Door
dp dp dp dp
Concrete tilt panel infill
0
,49 1,924 6,064 8,522 7,465 7,460 7,462 6,097 8,503 6,092 7,540 7,542 7,058 7,073 7,986 7,085 7,227 9,013
16
A B Line of existing awning over
3,852
Existing stormwater
from downpipes
bo
un
da
ry
lin
e
Existing pedestrian
bridge and path
Existing Drain
Line of 6m
Landscape
buffer zone
Ground Floor Plan
1:200
0 5m 25m
WIMMERS FACTORY 06 September 2013
SCALE 1 : 200 @ A1
271 Lake Macdonald dr.
ROBINSON
A RC HIT ECT S
Lake Macdonald PAGE No. DA-03 Copyright of Robinson Architects 2013.
Page 4
A
B
VOID
Storage
Sick
Bath
Tea WC
dwn
22
Landing/ Meeting
Viewing Deck
2,700
Pod
PA Wait
Sales MD
C C
Manufacturing Area Below
1M h WALL
Board Rm
Balc
VOID
1M h WALL
Light
Well
A B
Mezanine Floor Plan
1 1:200
SUNSHINE COAST REGIONAL COUNCIL
APPROVED
MCU 13/0171 1 NOV 13
0 5m 25m
WIMMERS FACTORY 06 September 2013
SCALE 1 : 200 @ A1
271 Lake Macdonald dr.
ROBINSON
A RC HIT ECT S
Lake Macdonald PAGE No. DA-04 Copyright of Robinson Architects 2013.
Page 5
Existing vent roof beyond Angled openings in screen
Bubbles :
Existing Proposed Galv. metal tanks
Screen
with coloured glass inserts
Aluminium angles
Concrete Panels
trowelled finish
9700
300
3,500
300
Timber fence & gate Proposed Entry Arbour Proposed automatic Proposed full - height
Polished conrete plynth Pivot doors Existing portal frame
curved steel sliding entry doors glass curtain wall
Southern Elevation
1:100
Existing roof vent
Zincalume Proposed Existing
gable cladding
9700
6000
4500
Proposed concrete Proposed Fence
Proposed roller doors
panels
Northern Elevation
1:100 SUNSHINE COAST REGIONAL COUNCIL
APPROVED
MCU 13/0171 1 NOV 13
0 5m 10m
WIMMERS FACTORY 06 September 2013
SCALE 1 : 100 @ A1
271 Lake Macdonald dr.
ROBINSON
A RC HIT ECT S
Lake Macdonald PAGE No. DA-05 Copyright of Robinson Architects 2013.
Page 6
Existing raised roof vent Polycarb roof Section
Existing roof to be re-lined
to be sealed at Light well
Entry Arbour
Fence beyond
Concrete plynth Entry Awning Existing portal frames Top hung glazed bi-fold door Proposed Roller Proposed concrete Existing floor level
door & glass panels
Raised floor level
Part Elevation
1:100
Existing raised roof vent Polycarb roof Section
Existing roof to be re-lined
to be sealed at Light well
Entry Arbour
Fence beyond
Concrete plynth Entry Awning Existing portal frames Top hung glazed bi-fold door Proposed Roller Proposed concrete Existing floor level
door & glass panels
Raised floor level
Eastern Elevation
1:200
SUNSHINE COAST REGIONAL COUNCIL
APPROVED
MCU 13/0171 1 NOV 13
0 5m 10m
WIMMERS FACTORY 06 September 2013
SCALE 1 : 100 @ A1
271 Lake Macdonald dr.
ROBINSON
A RC HIT ECT S
Lake Macdonald PAGE No. DA-06 Copyright of Robinson Architects 2013.