Log in to see the plans as drawn COPYRIGHT: Drawings remain the Copyright of the Architect: Shaun ROOF DRAINAGE: All downpipes to be located as noted on the
000.00 cover page perspective image C 20.08.21 a/c air conditioning unit
Lockyer drawings and sizes as scheduled. Allow to connect to in-ground storm
000.01 cover page legends and notes C 20.08.21 awn01 custom folded aluminium awning panel - type 1 water drains with 90mmØ UPVC at 1:100 minimum grade. Allow for
020.01 reference images reference images B 20.08.21 awn02 custom folded aluminium awning panel - type 2 ALL WORKS shall be carried out in accordance with the Building Code I.O.'s at each change of direction and at 6000mm centres.
040.01 existing conditions images C 20.08.21 cld01 castellated profile cladding - paint finish of Australia, Australian Standards, Local Council requirements, QDC
080.01 site plan existing site plan & locality plans C 20.08.21 con01 light honed / polished exposed concrete guidelines and all other relevant by laws and authorities. In particular SITE DISCHARGE: All stormwater and sanitary plumbing to be
100.01 site plan proposed site plan & locality plans B 20.08.21 cpt01 carpet flooring refer Australian standards: connected to existing council system in accordance with the
· site preparation A.S. 3798 requirements of the relevant local authority.
110.00 plans existing roof plan C 20.08.21 e-awn existing awning · concrete construction A.S. 2870
110.01 plans existing ground floor C 20.08.21 e-bal existing balustrade · timber construction and details A.S. 1684.2 WATER LINES: All hot water lines shall be fully insulated. All domestic
110.02 plans existing first floor C 20.08.21 e-con existing concrete · steelwork AS 4100, AS 1111 and A.S. 1112 hot water to basins, showers and baths to have maximum temperature
110.03 plans existing second floor C 20.08.21 e-cpt existing carpet flooring . termite protection BCA and A.S. 3660.1 of 50°C. Allow to supply and install tempering valves where required,
130.01 building elevations existing elevations C 20.08.21 e-dnp existing downpipe . artificial lighting & ventilation BCA parts 3.8.4/3.8.5 and A.S. 1680 as nominated in the BCA and relevant standards.
. fire safety BCA part 3.7
130.02 building elevations existing elevations C 20.08.21 e-epx existing expoy floor finish
. smoke alarms BCA part 3.7.2 and A.S. 3786 STAIR AND BALUSTRADES: All stair and balustrades shall comply
130.03 building elevations existing elevations C 20.08.21 e-fen existing fence . glazing BCA part 3.6 and A.S. 1288 and A.S. 2047 with part 3.9 of the BCA. Steps to be provided where fall from dwelling
140.01 building sections existing building section C 20.08.21 e-gar existing tilt panel garage door exceeds 190mm.
190.01 area plans ground floor GFA B 20.08.21 e-lfc existing rendered fc sheet APPROVAL: No building work shall be undertaken prior to Building
190.02 area plans first floor GFA B 20.08.21 e-mtf existing metal flashings Approval by a registered Certifier. ALL PRODUCTS: To be installed to manufacturers requirements and
190.03 area plans second floor GFA B 20.08.21 e-mtg existing metal eaves gutter to be in accordance with manufacturers requirements for suitable
CONSULTANTS: Drawings shall be read in conjunction with engineers exposure levels.
200.00 roof plan proposed roof plan B 20.08.21 e-mts existing metal roof sheeting
drawings and computations. All structure to Engineers design.
200.01 floor plans proposed ground floor B 20.08.21 e-pav existing paving Hydraulic sizing and design to hydraulic engineers requirements. All PROPRIETARY ITEMS: Identification of a proprietary item does not
200.02 floor plans proposed first floor B 20.08.21 e-plf existing pool fence drawings to be co-ordinated with consultant documentation prior to necessarily imply exclusive preference for the item so identified, but
200.03 floor plans proposed second floor B 20.08.21 e-rnd existing rendered finish construction. indicates the necessary properties of the item. If alternatives are
300.01 building elevations proposed elevations B 20.08.21 e-rtw existing timber sleeper retaining wall proposed, submit proposed alternatives and include samples, available
300.02 building elevations proposed elevations B 20.08.21 e-tbs existing timber batten screen DIMENSIONS: Do not scale off drawings - use figured dimensions only. technical information, reasons for proposed substitutions and cost.
Contractor shall verify all dimensions on site prior to construction. Any
300.03 building elevations proposed elevations B 20.08.21 e-tdk existing timber decking
discrepancies or errors shall be referred to architect and client prior to TILES: Expansion joints, walls: 5mm. Floors: 8mm. Fill both with
400.01 building sections proposed sections B 20.08.21 e-til existing tile surface installation / manufacture of any works. Confirm levels & RL's on site silicone rubber. Grout for wall: Epoxy based mildew resistant. Grout for
400.02 building sections proposed sections B 20.08.21 e-wdh existing window hood prior to commencement of work. floors: prepared grout to be acid resistant. all wall tiles to have
400.03 building sections proposed sections B 20.08.21 gar01 tilt panel garage door fcsubstrate.
400.04 building sections proposed sections B 20.08.21 hsn01 house / unit number SETOUT: Contractor to confirm exact siting and orientation prior to
general construction notes
construction setout. All building setout and confirmation of setbacks
architectural drawing list
lfc01 Scyon HardieTex (or similar) rendered fc sheet INTERNAL PAINTING: Unless noted otherwise paint system to be
and height to be carried out by a Licensed Surveyor. No footing, or wall Dulux approved 3 coat system - low sheen finish. Colours to be
mtf01 custom folded metal flashings to encroach the title boundary. supplied by Architect during contract and applied as per Dulux's
plf01 frameless glass pool fence (propreitary) recommendations and guidelines.
rnd01 to suit e-rnd TERMITE PROTECTION: Termite protection by means of termimesh
legend
scr01 batten screen - paint finish s.s. mesh hysical barrier in accordance with A.S. 3660.1/2000 and JOINERY ITEMS SHALL INCLUDE: Manufactured casework items,
skl01 proprietary fixed skylights (Velux or similar) type 1 installed in strict accordance with current manufacturers specifications. including: kitchen cabinets and cupboards; bathroom cabinets; robes.
skl02 proprietary fixed skylights (Velux or similar) type 2
STRUCTURAL STEEL: Unless noted otherwise all exposed SANITARY COMPARTMENTS: Provide removable hinges to doors of
til01 tile finish - type 1 structuralsteel, anchor bolts and other attachments shall be hot dip sanitary compartments to comply with BCA 3.8.3.3 and be readily
til02 tile finish - type 2 galvanised. A cold gal painted finish shall be applied to any field removable from outside unless there is a clear space of at least
tim01 internal timber flooring welding to existing or new steelwork. All steel work cast in concrete 1200mm b/w closet pan within the sanitary compartment and the
footings or slab shall have a bitumen finish applied to full extent of cast nearest part of the doorway.
in concrete steel. Check all dimensions on site prior to fabrication of
steelwork. APPLIANCES & EQUIPMENT: Builder to co-ordinate all appliance and
equipment locations on site and with joiner. installation and final
RETAINING WALLS: All retaining walls to structural engineers details. connection by the contractor.
Provide rubble backfill and agg drainage to all retaining walls. Builder to
provide tanking where required. WEATHERSTRIPS: All external doors to contain weather stripping
(type to be confirmed by Architect prior to manufacture)
SLAB & FOOTINGS: All slabs and footings to structural engineers
details. A polyethylene moisture barrier shall be lapped 200mm and DOCUMENTATION: The contractor shall carry out works in
fully taped under any habitable concrete slab and shall extend 100mm accordance with the signed drawings and schedules and anything
onto the perimeter footing. reasonable inferred, and with the Conditions of Contract, and in
accordance with the directions and to the satisfaction of the Architect,
ARTICULATION JOINTS: Provide articulation joints to comply with whose interpretation of the contract documents shall be final. The
"Cement and Concrete Association Construction Note TN9". drawings and specifications/schedules shall be considered
complementary, and any
EROSION CONTROLS: All building works to comply with local work and/or materials absent from one but present or implied in the
authorities Erosion and sediment control standards. other shall be furnished as if they were present in both.
WATERPROOFING: All wet areas and walls to be waterproofed in FINAL CERTIFICATE: At completion of work, Builder to obtain and
accordance with the BCA 3.8 & AS 3740. Builder to provide certificate supply a Certificate of Classification from a Building Certifier.
of installation and compliance.
POOL: Contractor to confirm heights/depths/steps and
CONCEALMENT OF SERVICES: All services shall be concealed in plumbing/electrical requirements and locations prior to construction
walls or ducts. Where services are exposed they must be confirmed by
the Designer on site prior to installation unless noted otherwise.
LICENSED TRADESPERSONS: All services to be installed by licensed
tradespersons in accordance with local authority and with current
manufacturers specifications.
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0296
AB
JW
C
B
20.08.21
12.04.21
development application issue
schematic design
3 | 18 Peregian Esplanade Macushla & Robert Jackson cover page SD 000.01 C SCALE 1:1
JW A 26.03.21 measured drawings Peregian Beach QLD 4573 legends and notes
schematic design
1:1 @ A3
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.