MCU Application 11/12/2008 Page 21
dame PN
with Section 3 of AS/NZS
02 Driveways and crossovers— $2.1 Design of the driveway ¥ Complies.
a) are suitable and safe for their intended use; | across the footpath is in
and accordance with Council's
b) match Council infrastructure. Standard Drawings 9002 or
9005 as appropriate for the
particular type of development
as annotated on the drawings;
AND
$2.2 Driveways are designed
and constructed in accordance
with Council Standard
Drawings 9014, 9019, 9020,
9021, as appropriate for the
particular type of development
as annotated on the drawings;
AND
$2.3 The change in grades in
the driveways and ramps is in
° accordance with Section 3 of
AS2890.1 Parking Facilities.
03 In commercial zoned areas, the number of | $3.7 Design of multi-tenanted v NIA
driveways across pedestrian footpaths is developments in commercial
minimised. zoned areas include shared
driveways and parking areas;
AND
$3.2 Driveways are locatedso | WW N/A
they abut existing driveways of
adjoining development where
practicable and reciprocal
easements are created to
reduce the sealed driveway
width.
04 Vehicular access does not adversely $4.1 Footpath and kerb ~ Complies.
impact on the capacity, operations and crossings are located clear of
maintenance of the existing infrastructure; existing stormwater inlet
AND structures, water and sewerage
O85 Vehicular access does not adversely infrastructure fittings, any other
. impact on the integrity of existing landscaping | exiting utility infrastructure,
© or native vegetation. existing landscaping and
vegetation.
$5.1 No solution provided
06 Driveway run-off is filtered prior to leaving | $6.7 For— ~ Complies. Appropriate
the premises. a) Ancillary dwelling unit, stormwater quality will be
Multiple housing Types 4 or 2 | directed to landscape areas.
if less than 5 carparking
spaces, Visitor
accommodation Type 1 and
Home based business—the
driveway is formed to drain to
landscaped areas; and
b) for other uses—grease and
oil arrestors or stormwater
quality improvement devices
are incorporated into the
design to treat run-off prior to
run-off exiting from the
premises.
Material Change of Use P. Conyers & K. O'Brien
34 Elanda Street, Sunshine Beach Oct 2008See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
001981A9.001.pdfRelated documentPublic source context ↗
08/2093 - MCU - Mutliple Housing Type 2 - Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.