Council archive · source document
92 hilton tce - development parameters assessment · SPS25/0003
Development parameters and compliance with Noosa Plan 2020 (Amendment No.1 25 September 2020) for 92 Hilton Tce, Noosaville Plans: Drawing Numbers 0.0 to 8.0, drawn by Paul Clout Design and dated 24.10.2025 Criteria Noosa Plan 2020 Proposal Compliance (V1 - 25 Sept 2020) Zone Medium Density Residential – site Site Details 1,937m² Medium Density Residential Code Secondary Dwelling (AO3) No more than one No home based Not applicable secondary dwelling, business 65m2 and 2 beds proposed Height (AO8) 8m and 2 storeys 8.5m and 2 PO – 8.5m to middle pitch of roof storeys Site Cover (AO10) 40% - 776m² 34% - 658m² Y 24% - 451m²
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 4 pages
Page 2
Plot ratio (AO11) 0.4:1 – 776m² 0.39:1 – 760m² Y = 123 + 274 + 271 + 48 + 15 = 731m2 (see planner calculations below)
based on designer
calculations
Page 3
Setbacks (AO12) Frontage
(6m) 6m Y
AO12.2 – Pools and <1m Y
cars no greater than
1m above NGL and
setback min 2m
west side 0.0m PO – Bicycle storage 0.0m and feature wall within 1.5m setback
(1.5m / 2m)
east side 1.5 to 2m+ Y
(1.5m / 2m / 2.5m
>7.5m)
Rear (10m from MHWS) >10m to PO – Pool structure and pavilion is within 10m setback
structure/building
>1m in height
Setbacks Noosa Waters 4.5m Not applicable
(AO13)
Building design (AO14.5) Y – visual interest
For a dwelling house, development provides visual interest to the street
and the surrounding area through:
N/A
(a) limiting the vertical distance between the ground and the lowest
suspended floor to no more than 3 metres;
(b) limiting the length of any external wall in one plane to 15 metres; Wall broken up
and by openings
(c) ensuring each external wall includes at least one design element
(<15m), including
such as verandahs, external stairs, window openings, awnings or
porches verandas and
windows facing
street.
Garages (AO15) Only one garage Y
Garage doors that face the street are no more than 6 metres in facing street at
width or 50% of the frontage, whichever is the lesser.
5.6m wide.
Where multiple garages face the street, they are separated by a
minimum of 2 metres or are staggered in setback by a minimum Second garage
of 1 metre. does not face
street and
Page 4
Garages that are visible from the street, but do not face the street, includes
include a landscaped setback to the street and provide
landscape
articulation, windows or a mix of materials to provide interest to
the garage facade. setback, with mix
of materials
around feature
tree.
Basements and Garages (AO15 & 16) Basement not in Y
Limited to one garage 6m wide and not in setbacks setbacks
Roof Form (AO19) No parapet Y – setback 1.5m for structure (not including any temporary shoring)
The total width of any parapet wall does not exceed 50%
of the width of the front facade of a building.
Front fencing (AO17) Fencing setback Y
Front fencing and wall setback 1m and landscaped and if >1m
on boundary a max. 1.2m in height or 50% transparent.
Roof Forms (AO19) 5 degree pitch Y
5 degree roof pitch and minimum 600mm eaves to 75% and eaves to
of building and parapets facing street <50% of façade. >75% of building.
Parapets also not
facing street.
Mechanical Plant and Sports Courts (AO21) Mechanical plant
Light restrictions for outdoor courts and mechanical plant integrated into
integrated building design
and no lit court.
Cut / Fill (AO22) <1.5m Y - While cut for the basement is >1.5m, the AO references landscaping purposes external to the
1.5m for landscape amenity reasons building. Baxter v Preston & Ors (2022)
Sloping Sites (AO23) Not Applicable
Split level building alternatives
Earthworks and Drainage (AO24) Y – Able to drain to legal point of discharge to Hilton Tce.
Overland flow non-worsening
Low Density Housing Code
Landscaping (AO6) 20% to be soft >20% Y
landscaping
Carparking and driveway 2 covered and 6 covered Y – can be conditioned as part of BA
(AO7-14) driveway design spaces
criteria
Flood Hazard (AO16) 300mm above DFE 2.7m AHD Y – in accordance with flood search
Page 5
Earthworks (AO21) Filling other than Fill for pool PO – Filling around pool terrace more than 3m from building
accessways is limited terrace <1m,
to 500m2 and less however more
than 3m from outer than 3m from
walls. building along
Noosa River.
Acid Sulfate Soils Overlay Code
Avoidance and Management Acid sulfate soils Not undertaken PO – Able to be complied with and reporting included with application.
of ASS (AO1) reporting and
management
Flood Hazard Overlay Code
Flooding (AO1 – AO11) 1%AEP flood immunity Minimum floor PO – Filling around pool terrace more than 3m from building
+ 300mm free board height are
Minimal fill to reduce chieved with
flood risk minimal external
filling beyond the
footprint
Used in these records
92 hilton tce - development parameters assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 750 KB (small file)
- File type
No other editions are linked here.