Appendix 5- Response to Planning Scheme Codes · MCU17/0027
Attached to the e-mail Engineering plans, Landscape Plan and Response to Code (Email 2 of 2) MCU17/0027 & OPW17/0119.
Specific Outcomes, probable solutions and acceptable solutions for the Residential
Uses Code
(1) For All Residential Uses
SPECIFIC OUTCOMES/ PROBALE SOLUTIONS COMMENT
Electricity supply AO1 Complies
O1 S1.1 No solution provided
infrastructure O1 The
development does not AO2
Not Applicable
adversely impact on S2.1 Development for uses adjacent to or
existing or future electricity within 50m of an existing electricity
supply infrastructure; AND substation incorporates noise attenuation
O2 measures to mitigate noise impacts; AND
All uses and works S2.2 Buildings and structures (including Complies
maintain an adequate safe swimming pools, sheds, tennis courts or
distance from electrical outbuildings) are not constructed under
infrastructure including overhead electricity transmission lines, or
substations, overhead within electricity easements; AND
powerlines, power poles S2.3 A minimum separation distance is Complies
and transformers. maintained from the electricity
transmission line to the closest boundary
of habitable buildings and child activity
areas, as follows— a) 20m for
transmission lines up to 132kV; b) 30m
for transmission lines between 133kV
and 275kV; and c) 40m for transmission
lines greater than 275kV.
Hot Water Systems AO3 Complies
O3 S3.1 All hot water systems installed are—
Hot water systems are a) solar systems; or b) electric heat pump
installed and operated to
systems; or c) natural gas or LPG
support the efficient use of
natural resources and systems; or d) any combination of a), b)
minimise consequent or c).
pollution such as
greenhouse gas emissions.
Water supply and AO4 Not Applicable
conservation S4.1 & S5.1 For a Class 1 building15 The proposed development will be
O4 other than a Detached house or Multiple connected to a reticulated water
On-site water storage is
Housing Type 1, outside a reticulated supply which can be connected at
designed and operated to
support the efficient use of water service area, a rainwater tank is to the subject site frontage. One
water; be installed with the following minimum water meter will be utilised for the
storage capacities— a) Where no more development.
AND than 3 bedrooms – 45,000 litres; or b)
O5 On-site water storage is Where more than 3 bedrooms – 60,000
adequate for occupants litres; AND c) There is to be on the lot a
every day use and fire
dam, swimming pool or water tank
fighting purposes.
accessible for use by the fire brigade that
contains at least 5,000 litres of water.
Advisory note The 5,000 litres required
can be included within the water required
in S4.2 or S5.1 providing it is accessible
for the purpose of fire fighting at all times
and not used for other domestic
purposes.
Erosion and sediment AO6 Complies
control No solution provided. The development will not cause
O6 erosion or result in the transport
Development does not
Advisory Note Persons undertaking of sediments off-site.
cause erosion or result in
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix 5- Response to Planning Scheme Codes.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.0 MB (small file)
- File type
No other editions are linked here.