equipment associated with refrigeration units are— a) where located
Residential Uses are at ground level, screened by fencing
designed and located so as 1.5m in height or dense vegetation of at
not have an adverse impact
least 1.5m in width incorporating grouped
on the visual amenity of the
site or surrounding areas. trees and shrubs with maximum
separation distance of 1m measured from
the centre of the plant; and b) for Multiple
housing Type 2, 3 & 4 are visually
integrated into the line and plane of the
building and roof design and do not
project beyond the height or width of the
building when viewed from the street and
adjoining properties.
Ancillary recreation uses AO12 Not Applicable
O12 S12.1 If the use involves ancillary use of
Ancillary recreation uses, outdoor courts including tennis courts,
such as outdoor tennis
half courts and netball courts—the use
courts and half netball
courts, do not have an complies with the requirements in Section
adverse effect on the 2 of PSP8 Tennis and Other Courts; AND
amenity enjoyed by users of
adjacent or nearby premises S12.2 Any lit tennis court or sports court Not Applicable
nor do they cause is located at least 60m from the external
unreasonable disturbance wall of an existing or approved residential
to local fauna through light
dwelling on an adjacent or nearby lot (as
emissions by ensuring that
all lighting devices are measured from the centre line of the
limited to those designed court); AND Complies
and installed to: a) minimise S12.3 The vertical illumination resulting
light spillage on from direct, reflected or other incidental
neighbouring premises; b) light emanating from the site does not
preserve an acceptable exceed 8 lux when measured at any point
degree of lighting amenity
at the neighbouring 1.5m outside the boundary and at any
premises; c) provide covers level from ground level upward; AND Complies
or shading around lights; d) S12.4 Any flood lighting is restricted to
direct lights downwards; e) the types that give no upward component
position lights away from of light where mounted horizontally (i.e. a
possibly affected areas; and full cut off luminaire).
f) enable brightness of
lights to be adjusted to low
levels.
O13
Noise originating from the AO13 Not Applicable
use of the tennis court does S13.1 The court is not used between the
not have a detrimental effect hours of 10:00pm and 6:30am the
on the amenity of the area
following day
or cause nuisance to
neighbouring residents.
Privacy AO14 Complies
O14 S14.1 Transparent doors and windows
For Multiple Housing Types are designed and located so they do not
2, 3 and 4, building and
directly face transparent doors or
structures are designed and
sited to ensure the visual windows or the private open space areas
privacy of residents of the of other dwelling units within 10 metres;
development and AND
neighbouring properties is S14.2 Planter boxes, louvre screens, Complies
protected. Figure 14-3 pergolas, landscaping and architectural
Privacy Measures
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix 5- Response to Planning Scheme Codes.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.0 MB (small file)
- File type
No other editions are linked here.